Intellivent Versus Conventional Ventilation

NCT01577667 · Status: COMPLETED · Phase: PHASE3 · Type: INTERVENTIONAL · Enrollment: 80

Last updated 2012-12-06

No results posted yet for this study

Summary

Partial automation of mechanical ventilation in resuscitation has been available for several years. New modalities are being developed to completely automate ventilation and oxygenation parameters (IntelliVent®.

This pilot study compares over a 48h period the safety and efficacy of IntelliVent®, versus a conventional ventilation modality.

Conditions

Interventions

DEVICE

Intellivent; automatic mode implemented on a S1 ventilator

Intellivent allows an automatic adjustment of the following parameters: FiO2, PEEP and %VM according to adjusted parameters: Size, SpO2 and EtCO2

Sponsors & Collaborators

  • Hamilton Medical AG

    lead INDUSTRY

Principal Investigators

  • Pierre-François Laterre, Pr · Reanimation, Cliniques Universitaires Saint Luc

Study Design

Allocation
RANDOMIZED
Purpose
SUPPORTIVE_CARE
Masking
SINGLE
Model
PARALLEL

Eligibility

Min Age
18 Years
Max Age
90 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2011-02-28
Primary Completion
2012-04-30
Completion
2012-06-30

Countries

  • Belgium

Study Locations

More Related Trials

Entities

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.