Short Implants - An Alternative to Bone Grafting?

NCT01030523 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 101

Last updated 2023-04-06

Study results available
· View outcomes & findings →

Summary

The study, with the ASTRA TECH Implant System, is comparing short implants (OsseoSpeed™) to standard length implants (OsseoSpeed™) in combination with bone grafting. The hypothesis is that the use of short implants in posterior maxilla with inadequate bone is as safe and predictable as placing standard length implants in combination with bone augmentation.

Conditions

  • Jaw, Edentulous, Partially

Interventions

DEVICE

ASTRA TECH Implant System, OsseoSpeed™ 4.0 S (length: 6 mm)

ASTRA TECH Implant System, OsseoSpeed™ 4.0 S (length: 6 mm)

DEVICE

ASTRA TECH Implant System, OsseoSpeed™ implants (lengths: 11, 13, 15 mm) in combination with bone grafting

ASTRA TECH Implant System, OsseoSpeed™ implants (lengths: 11, 13, 15 mm) in combination with bone grafting

Sponsors & Collaborators

  • Dentsply Sirona Implants and Consumables

    lead INDUSTRY

Principal Investigators

  • Christoph Hämmerle, Prof. Dr. · Zentrum für Zahn-, Mund- und Kieferheilkunde der Universität Zürich

Study Design

Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Model
PARALLEL

Eligibility

Min Age
20 Years
Max Age
75 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2009-10-31
Primary Completion
2016-12-31
Completion
2022-03-22
FDA Device
Yes

Countries

  • United States
  • Austria
  • Poland
  • Spain
  • Switzerland

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT01030523 on ClinicalTrials.gov