Accuracy of AI Assisted Surgical Guide (AISG)
NCT07711613 · Status: NOT_YET_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 20
Last updated 2026-07-17
Summary
The purpose of this study is to evaluate and compare the accuracy of conventional static surgical guide and AI-assisted static surgical guide in implant placement in the esthetic zone of partially edentulous maxilla , This study will be carried out on patients seeking implant placement in partially edentulous esthetic zone of maxilla, selected from those who were referred to outpatient clinic of the department of oral and maxillofacial surgery, Faculty of Dentistry, Suez Canal University. The main research question is assessing what the difference is upon using AI-assisted surgical guide in terms of the accuracy of implant angular and linear deviation, and implant depth. The expected outcome is that The use of AI-assisted surgical guide in implant placement may provide higher accuracy and less deviation than the conventional static surgical guide. This clinical study will be conducted on 20 surgical guides for placement of 20 implants, divided into 2 groups: Group 1: 10 conventional computer-guided static guides for placement of 10 implants (as control group) Group 2: 10 AI-assisted static surgical guides for placement of 10 implants (as study group) The selected patients will get a pre operative CBCT scan and an intraoral scan then the guide design and generation will be performed using conventional software or AI integrated software according to randomization chart generated by "www.randomizer.org", and after the surgery of implant placement through the prefabricated guides the patients will get an immediate post operative CBCT scan.
Conditions
- Accuracy of AI App
- Accuracy of AI Assisted Surgical Guides
Interventions
- PROCEDURE
-
Implant placement using Conventional static surgical guide
Conventional digitally planned surgical guide used for guided implant placement.
- PROCEDURE
-
Implant placement using AI assisted surgical guide
AI assisted surgical guide for guided placement of dental implants
Sponsors & Collaborators
-
Suez Canal University
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 21 Years
- Max Age
- 60 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2026-07-14
- Primary Completion
- 2027-05-14
- Completion
- 2027-07-14
Countries
- Egypt
Study Locations
More Related Trials
-
Digitally Assisted Immediate Implants in Geriatric Patients
NCT07534514 ·Status: RECRUITING
-
Artificial Intelligence Assisted Socket Shield With Computer Guided Implant Placement
NCT06299449 ·Status: COMPLETED ·Phase: NA
-
An Immediate Implant Will be Placed Using the MiniNaviDent System and Static Guide. A Postoperative CBCT Scan Will Then be Acquired and Superimposed Onto the Preoperative CBCT Scan to Assess and Compare Implant Deviation Relative to the Preoperative Plan
NCT07380360 ·Status: COMPLETED ·Phase: NA
-
Classifying Fully Guided Surgical Guides
NCT06947057 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Accuracy of Fully Guided Dental Implant Placement by Experienced and Novice Clinicians Using Different Surgical Guides
NCT07112664 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Evaluation of Accuracy of Three-Dimensionally Guided Zygomatic Implant Installation
NCT07463469 ·Status: COMPLETED ·Phase: NA
-
All-on-X Stackable Guides for Maxillary Terminal Dentition
NCT07353619 ·Status: RECRUITING
-
Fully Guided Dental Implant Placement and Primary Stability
NCT07149987 ·Status: COMPLETED ·Phase: NA
-
Accuracy of Guided Implant Placement Using Artificial Intelligence Segmentation Versus Conventional Technique
NCT06967090 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Effect of Face Scanning on Accuracy of Dental Implant Placement in Fixed Implant Supported Maxillary Prostheses
NCT06001515 ·Status: RECRUITING ·Phase: NA
-
Radiographic Assessment of Three Dimensional Mandibular Position Using Splint-less Patient Specific Implant
NCT06160661 ·Status: RECRUITING ·Phase: NA
-
Accuracy of Trephination-based Versus Drilling-based Guided Dental Implant Placement
NCT05295082 ·Status: COMPLETED ·Phase: NA
-
A Study of Surgical Guide Assisted Dental Implantation in Bangladesh
NCT05983718 ·Status: UNKNOWN ·Phase: NA
-
Passivity of Full-Arch Co-Cr Maxillary Prostheses Using IOS
NCT07370701 ·Status: COMPLETED ·Phase: NA
-
Comparing Dynamic Navigation to Static Navigation in the Implant Placement
NCT07291336 ·Status: RECRUITING ·Phase: PHASE4
-
Edentulous Maxilla Opposed by 2-implant Mandibular Overdenture?
NCT06050213 ·Status: UNKNOWN ·Phase: NA
-
"Computer-Guided vs Freehand Zygomatic Implant Placement
NCT06925438 ·Status: COMPLETED ·Phase: NA
-
Swallowing Threshold and Efficiency for Maxillary Implant Assisted Overdenture
NCT06622837 ·Status: COMPLETED ·Phase: NA
-
Clinical and Radiographic Evaluation of Delayed Dental Implant Placement After Socket Preservation Using Injectable Bone Graft
NCT07373600 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Clinical and Radiographic Assessment of the Outcomes of Dental Implant Inserted After Xenograft Socket Preservation in Posterior Maxilla
NCT07001813 ·Status: COMPLETED ·Phase: NA
-
Silicate-Added Beta-TCP in Fully Guided Immediate Implants in the Esthetic Zone
NCT07613320 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Assessment of a New Enhanced Xenograft in Open Maxillary Sinus Augmentation
NCT07737704 ·Status: RECRUITING ·Phase: PHASE2/PHASE3
-
Accuracy of Fully Guided Versus Half Guided Implant
NCT06542562 ·Status: COMPLETED ·Phase: NA
-
A I in the Prediction of Clinical Performance, Marginal Fit and Fracture Resistance of Vertical Versus Horizontal Margin Designs Fabricated With 2 Ceramic Materials
NCT06164002 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Implant Placement in Horizontally Deficient Maxillary Aesthetic Zone With Simultaneous Soft Tissue Augmentation
NCT05274256 ·Status: COMPLETED ·Phase: NA