In the past 5 years, there are increasing data suggesting that patients treated with mechanical ventilation experience shortness of breath, despite appropriate sedation. This adverse experience is believed to contribute to the finding that up to 25% of patients who survive severe respiratory diseases experience mental health problems including post traumatic distress syndrome (PTSD). The purpose of this study is to evaluate if/how sequential changes in the delivery of mechanical ventilation affect shortness of breath sensation in awake patients requiring mechanical ventilation. Improving the knowledge of the impact of the patient-ventilator interaction on shortness of breath sensation may lead to strategies to improve the comfort of non-sedated and sedated ventilated patients, and thereby reduce mental health sequelae in survivors of acute severe respiratory diseases The investigators hypothesize that current ventilator strategies, particularly reduced tidal volume (size of breath given by the ventilator) utilized in managing patients with severe respiratory diseases, contribute to shortness of breath in patients with increased drive to breathe. In this setting, some safe ventilator changes may improve or worsen the shortness of breath sensation in awake patients on mechanical ventilation.
Conditions
- Respiratory Failure
- Dyspnea During Mechanical Ventilation
- Mechanical Ventilation
Interventions
- OTHER
-
Change to VC/AC
All patients will be set on volume control/assist control (VC/AC) with flow at ramp and appropriate settings to approximate their initial tidal volume, minute ventilation, respiratory rate, FiO2 and PEEP. This change is routinely performed in the ICU. Patients already on VC/AC will be kept on same settings. The investigators will check dyspnea after this initial change.
- OTHER
-
Change in Tidal Volume
Change in 2mL/kg (increase and/or decrease) for 3 minutes. After every change the patient will rate dyspnea with an ordinal scale and The investigators will assess occlusion pressure at the mouth at the onset of inspiration (P0.1 and Pocc).
- OTHER
-
Change in inspiratory flow
Increase in 25% of baseline flow for 3 minutes Decrease in 25% of baseline flow for 3 minutes After every change the patient will rate dyspnea with an ordinal scale and the investigators will assess occlusion pressure at the mouth at the onset of inspiration (P0.1 and Pocc).
- OTHER
-
Change in PEEP
Change in PEEP by 5 cmH2O After every change the patient will rate dyspnea with an ordinal scale and the investigators will assess occlusion pressure at the mouth at the onset of inspiration (P0.1 and Pocc).
- OTHER
-
Change to PSV
Change to PSV to match their initial settings. After every change the patient will rate dyspnea with an ordinal scale and The investigators will assess occlusion pressure at the mouth at the onset of inspiration (P0.1 and Pocc).
Sponsors & Collaborators
-
Beth Israel Deaconess Medical Center
lead OTHER
Principal Investigators
-
Elias Baedorf-Kassis, MD · Beth Israel Deaconess Medical Center
-
Richard Schwartzstein, MD · Beth Israel Deaconess Medical Center
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2026-09-01
- Primary Completion
- 2027-06-01
- Completion
- 2027-07-01
Countries
- United States
Study Locations
More Related Trials
-
Mode Of Ventilation During Critical IllnEss Pilot Trial
NCT05563779 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Review of Automated Ventilator Data's Effect on the Incidence of Ventilator Associated Events in a Medical Surgical Intensive Care Unit
NCT03850340 ·Status: UNKNOWN
-
Mode of Ventilation During Critical Illness at Multiple Centers
NCT07313956 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Influence of Mechanical Ventilation Mode on Arterial Pressure Variations- a Pilot Study
NCT03246425 ·Status: WITHDRAWN ·Phase: NA
-
Ventilatory Parameters in Predicting Outcomes in ARDS Patients
NCT06400095 ·Status: RECRUITING
-
Outcome and Predictors of Mortality of Patients on Prolonged Mechanical Ventilation
NCT06087939 ·Status: NOT_YET_RECRUITING
-
Efficacy of Closed-loop Ventilation to Reduced Sleep Disorders
NCT02095496 ·Status: COMPLETED ·Phase: NA
-
Nursing Care for Breathing Discomfort Among Mechanically Ventilated Patients
NCT04019236 ·Status: UNKNOWN ·Phase: NA
-
Epidemiology and Treatment Strategy of Open Respiratory Phenotype in Critically Ill Patients
NCT06393179 ·Status: RECRUITING ·Phase: NA
-
Effect of Web-Based Adaptation and Insomnia Severity in Individuals Using Noninvasive Ventilators at Home
NCT06343324 ·Status: COMPLETED ·Phase: NA
-
Effectiveness of Sedation Management in an Australian Intensive Care Unit
NCT00202319 ·Status: COMPLETED ·Phase: NA
-
Effects Of Invasive And Noninvasive Mechanical Ventilation On Sleep In The Intensive Care Unit (ICU)
NCT00638339 ·Status: COMPLETED
-
Pilot Study on Pairing Sedation Strategies and Weaning
NCT02219659 ·Status: COMPLETED ·Phase: NA
-
Slope of the Pressure-Time Waveform Predicts Resistance and Compliance in Mechanically Ventilated Subjects
NCT00750074 ·Status: COMPLETED
-
Ventilator Hyperinflation With Increase of Inspiratory Time
NCT03630510 ·Status: COMPLETED ·Phase: NA
-
Effects of Different Driving Pressure on Lung Stress, Strain and Mechanical Power in Patients With Moderate to Severe ARDS
NCT03616704 ·Status: UNKNOWN
-
Effects of Sedation on Transpulmonary Pressure and Lung Homogenous
NCT03237806 ·Status: COMPLETED ·Phase: NA
-
Abbreviated Title: Airway Opening Pressure in Mechanically VENTilated Patients
NCT07512713 ·Status: NOT_YET_RECRUITING
-
Effect of End-inspiratory Airway Pressure Measurements on the Risk of VILI in Ventilated Patients
NCT05991258 ·Status: COMPLETED
-
Effects of Invasive Mechanical Ventilation on the Right Ventricular Function
NCT05710419 ·Status: UNKNOWN
-
CDC Prevention Epicenters Wake Up and Breathe Collaborative
NCT01583413 ·Status: COMPLETED ·Phase: NA
-
Optimization of Ventilator Setting for Acute Exacerbations of Chronic Obstructive Pulmonary Disease
NCT01291303 ·Status: COMPLETED ·Phase: NA
-
Dynamic Hyperinflation In Mechanically Ventilated Chronic Obstructive Pulmonary Disease Patients
NCT03230617 ·Status: UNKNOWN
-
The Effect of Semi-recumbent Position With Exercise Training on Long-term Ventilator-dependent Patients
NCT04822831 ·Status: COMPLETED ·Phase: NA
-
Impact of Non-invasive Positive Pressure Ventilation on Cardiac Function and Echocardiographic Parameters
NCT02267291 ·Status: COMPLETED ·Phase: NA