Effect of Continuous Supraglottic Oxygen Insufflation Via Video Laryngoscope Blade on Apneic Oxygenation During Tracheal Intubation Under General Anesthesia

NCT07662304 · Status: NOT_YET_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 150

Last updated 2026-06-23

No results posted yet for this study

Summary

This study is a prospective, randomized controlled clinical trial aimed at investigating the efficacy and safety of a novel oxygenating video laryngoscope blade during apneic oxygenation for intubation under general anesthesia. Hypoxemia is prone to occur during anesthesia induction, which can lead to severe complications. Apneic oxygenation is an important method to prolong the safe apnea time, but existing oxygen delivery modalities have limitations in applicability. Although the laryngeal oxygen delivery approach combined with video laryngoscopy has theoretical advantages, clinical evidence is insufficient. Therefore, this study was conducted.

Conditions

  • Apneic Oxygenation

Interventions

PROCEDURE

control group (Group C)

Before surgery, all participants received a radial arterial line. At arrival to the operating theatre, ECG, invasive arterial blood pressure, pulse oximetry, and train-of-four monitoring were applied. An i.v. line was secured, and a standard infusion of electrolyte solution was started. Participants were then placed supine, in a 10 degrees reverse Trendelenburg position. Preoxygenation was then perform using atight fitting face mask and having each subject breathe 100% O2 at 15 L/min.Tracheal intubation was thereafter performed using a video laryngoscope when the anaesthetist assessed the conditions as appropriate in the control group (Group C).The correct placement of the tracheal tube was confirmed visually by the anaesthetist in charge and a member of the study team. The tracheal tube was secured, and the participant was left apnoeic with the tracheal tube open to the atmosphere until the peripheral oxygen saturation declined to 93% or apnoea is sustained for 5 minutes.

DEVICE

The continuous laryngeal oxygen supply group (Group B)

The continuous laryngeal oxygen supply group (Group B) used the same preoxygenation and anesthesia induction methods as the control group. When intubation conditions were assessed to be met, laryngoscopy was performed to evaluate the airway. If the laryngoscopic view was Cormack and Lehane grade 3 or grade 4, the subject was excluded from the study and tracheal intubation was performed. Otherwise, continuous laryngeal oxygen supply was initiated through a modified disposable video laryngoscope blade, which has an internal lumen. The distal end of the blade is connected to an oxygen delivery tube, and the other end of the oxygen delivery tube is connected to a flowmeter, with an oxygen flow rate of 10 L/min to maintain a continuous oxygen supply to the larynx. Upon reaching an SpO2 of 93% or apnoea is sustained for 5 minutes, tracheal intubation and mechanical ventilation was commenced, and the protocol was terminated.

Sponsors & Collaborators

  • The Second Affiliated Hospital of Jiaxing University

    collaborator OTHER
  • Affiliated Hospital of Jiaxing University

    lead OTHER

Study Design

Allocation
RANDOMIZED
Purpose
PREVENTION
Masking
TRIPLE
Model
PARALLEL

Eligibility

Min Age
18 Years
Max Age
75 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2026-06-22
Primary Completion
2026-06-22
Completion
2029-06-22

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT07662304 on ClinicalTrials.gov