Effect of Individualized Positive End-expiratory Pressure (PEEP) in Patients Who Have an Intrinsic PEEP During One-lung Ventilation

NCT07638176 · Status: NOT_YET_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 48

Last updated 2026-06-10

No results posted yet for this study

Summary

This study investigates the effects of three extrinsic PEEP settings-5 cmH2O, 0 cmH2O, and an individualized PEEP (70% of the measured intrinsic PEEP)-on intrinsic PEEP and hemodynamic stability in patients with intrinsic PEEP undergoing lung resection surgery, using a randomized, crossover design.

Conditions

  • Pulmonary Disease (COPD), Chronic Obstructive
  • Lung Resection Surgery

Interventions

PROCEDURE

PEEP0

PEEP 0 (zero) means off-PEEP on the anesthesia machine.

PROCEDURE

PEEP5

PEEP5 means setting the PEEP to 5 cmH2O on the anesthesia machine.

PROCEDURE

PEEPi

PEEPi (individualized PEEP) means setting the PEEP to 70% of intrinsic PEEP on the anesthesia machine.

Sponsors & Collaborators

  • Samsung Medical Center

    lead OTHER

Principal Investigators

  • Hyun Joo Ahn, MD, PhD · Samsung Medical Center

Study Design

Allocation
NA
Purpose
TREATMENT
Masking
NONE
Model
SINGLE_GROUP

Eligibility

Min Age
19 Years
Max Age
100 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2026-06-01
Primary Completion
2027-05-31
Completion
2027-05-31

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT07638176 on ClinicalTrials.gov