Dimensional Changes of the Labial Alveolar Ridge After Socket Shield Technique With Computer Guided Root Sectioning
NCT05366985 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 10
Last updated 2022-05-11
Summary
In this study, the dimensional changes of the labial alveolar ridge are digitally assessed after immediate implant placement using the socket shield technique with computer guided sectioning of the root.
Conditions
- Edentulous Alveolar Ridge
- Dental Trauma
Interventions
- PROCEDURE
-
Socket shield technique with computer guided sectioning of the root
A computer guide was used to section the root, leaving the coronal 2/3 of its labial part attached to the socket. An implant was then placed. Preoperative and Postoperative (5 months later) intraoral scans were superimposed with a digital software to assess the dimensional changes of the labial alveolar ridge. Linear changes at 1,3 and 5 mm from the gingival margin and mean linear changes in a specified Area Of Interest (AOI) were measured
Sponsors & Collaborators
-
Alexandria University
collaborator OTHER -
Pharos University in Alexandria
lead OTHER
Principal Investigators
-
Ahmed K Nabawy, BDS · Alexandria university, Faculty of dentistry
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2021-09-01
- Primary Completion
- 2022-07-03
- Completion
- 2022-07-30
Countries
- Egypt
Study Locations
More Related Trials
-
Immediate Implant Placement With Connective Tissue Graft or Socket Shield
NCT03594019 ·Status: UNKNOWN ·Phase: PHASE3
-
Socket Shield With Immediate Implant Stability
NCT04882761 ·Status: COMPLETED ·Phase: PHASE4
-
Immediate Implant With Different Filling Materials
NCT05878392 ·Status: COMPLETED ·Phase: NA
-
Different Surgical Drilling Protocols in Posterior Maxilla
NCT06334081 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Socket Shield vs Conventional Immediate Implant
NCT03587597 ·Status: UNKNOWN ·Phase: NA
-
Socket-Shield Technique With Immediate Implant
NCT05673122 ·Status: UNKNOWN ·Phase: NA
-
Labial Bone Thickness Around Immediate Implants in the Esthetic Zone Following a Novel Socket Evaluation System
NCT06648135 ·Status: NOT_YET_RECRUITING
-
: SOCKET SHIELD TECHNIQUE VERSUS EMPTY SOCKET TECHNIQUE
NCT02992366 ·Status: UNKNOWN ·Phase: NA
-
Anterior Mandibular Region for Immediate Implant Placement
NCT06527950 ·Status: ACTIVE_NOT_RECRUITING
-
Esthetic, Clinical and Radiographic Outcomes of Immediate and Delayed Implant Placement
NCT02814149 ·Status: RECRUITING ·Phase: NA
-
Differences Between Two Type Implants in Post-extraction Alveolus
NCT05665231 ·Status: COMPLETED ·Phase: NA
-
Socket Shield Technique Versus Conventional Immediate Implant Placement in Thin Buccofacial Bone
NCT03264053 ·Status: UNKNOWN ·Phase: NA
-
Immediate Implants With Customized Abutments
NCT05638958 ·Status: UNKNOWN ·Phase: NA
-
Clinical and Radiographic Assessment of the Outcomes of Dental Implant Inserted After Xenograft Socket Preservation in Posterior Maxilla
NCT07001813 ·Status: COMPLETED ·Phase: NA
-
Influence of Abutment Angulation on Implant Failure in Immediately Placed and Restored Implants in the Esthetic Zone Using Computer Aided Surgical Guides: RCT
NCT03243695 ·Status: COMPLETED ·Phase: NA
-
Using Sealing Socket Abutment Technique With Immediate Implant in the Mandibular Molars
NCT03667261 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Ridge Dimensional Changes After Immediate Implantation and Efficacy of This Procedure
NCT01399775 ·Status: COMPLETED ·Phase: PHASE1/PHASE2
-
Jumping Gap Dimension at Maxillary Teeth: Cone-Beam Computed Tomography (CBCT) Study
NCT04636385 ·Status: COMPLETED
-
Relate Tooth Alveolar Extraction Socket Anatomy to Alveolar Remodeling Rate
NCT01963884 ·Status: UNKNOWN
-
Artificial Intelligence Assisted Socket Shield With Computer Guided Implant Placement
NCT06299449 ·Status: COMPLETED ·Phase: NA
-
The Evaluation of Facial Bone Changes After Early Implant Placement Protocols "Clinically and Radiographically".
NCT06165913 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Effect of Concentrated Growth Factors on Short Implant-Supported Overdentures
NCT06880965 ·Status: COMPLETED ·Phase: PHASE2/PHASE3
-
Buccal and Palatal Bone Thickness and Marginal Bone Changes Implants
NCT05632172 ·Status: COMPLETED
-
Socket Shield Technique for Immediate and Delayed Implant Placement: A 6-Year Clinical Tria
NCT07171866 ·Status: COMPLETED ·Phase: NA
-
Immediate Implant With Cusomized Healing Abutment
NCT04517968 ·Status: COMPLETED ·Phase: NA