The aim of this study is to reduce the time to ambulation after PVI by a vascular closure device as compared to manual compression and a figure-of-8 suture only. Safety, efficacy and feasibility of the VASCADE MVP device should be proven, too. The definition of endpoints will be trained in all participating study sites to preserve consistency.
The primary efficacy endpoint is time to ambulation after sheath removal. Time to ambulation is defined as the elapsed time between removal of the final closure device or removal of the final sheath and when the patient can stand and walk 20 ft without evidence of venous re-bleeding from the femoral access site.
The primary safety endpoint is the incidence of major periprocedural adverse events defined as adverse events until hospital discharge requiring medical intervention. Vascular access complications requiring solely the application of a pressure bandage will be classified as minor adverse event.
After fulfillment of all inclusion and exclusion criteria (see 5.1. and 5.2.) and written informed consent, patients will be randomized to either group 1 or group 2 in a 1:1 ratio:
Group 1:
50 patients treated with VASCADE MVP to achieve hemostasis
Group 2:
50 patients treated with manual compression and one figure of eight suture Clinical follow-up will be evaluated at hospital discharge, as well as at day 30 by a phone call using a standardized questionnaire. This will be performed as part of clinical routine. The follow-up period starts following randomization at day 1 after PVI.
An overview on the assessment of the study endpoints with the corresponding time point is displayed in the following table. During in hospital stay, need for pain medication due to issues of the femoral access site will be documented separately
Conditions
Interventions
- DEVICE
-
Vacular closure
Vascular closure device
Sponsors & Collaborators
-
Haemonetics Corporation
collaborator INDUSTRY -
Asklepios proresearch
lead INDUSTRY
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 95 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2025-04-22
- Primary Completion
- 2026-10-01
- Completion
- 2026-12-01
Countries
- Germany
Study Locations
More Related Trials
-
Tailored vs. Anatomical Ablation Strategy for Persistent Atrial Fibrillation
NCT04702451 ·Status: COMPLETED ·Phase: NA
-
Unexcitability Along the Ablation as an Endpoint for Atrial Fibrillation Ablation
NCT01724437 ·Status: COMPLETED ·Phase: NA
-
Clinical and Healthcare Outcomes From Real-World Use in the United States of a Companion AI During AF Ablation
NCT06056271 ·Status: RECRUITING
-
Clinical Study of the CardioFocus Endoscopic Ablation System for the Treatment of Symptomatic AF
NCT00958165 ·Status: COMPLETED ·Phase: PHASE3
-
Vagal Nerve Stimulation for the Treatment of Persistent AF
NCT05833373 ·Status: RECRUITING ·Phase: NA
-
Pulsed Field or Cryoballoon Pulmonary Vein Isolation for Atrial Fibrillation in Heart Failure
NCT07181291 ·Status: COMPLETED
-
Contact Force Guided Ablation Versus Conventional Pulmonary Vein Isolation for Paroxysmal Atrial Fibrillation
NCT02816268 ·Status: COMPLETED ·Phase: NA
-
Left Atrial Arrhythmia Substrate Identification After Confirmed durABLE Pulmonary Vein Isolation
NCT04111731 ·Status: COMPLETED ·Phase: NA
-
His-pacing and AV-node Ablation vs. Pulmonary Vein Isolation for Atrial Fibrillation
NCT04512586 ·Status: TERMINATED ·Phase: NA
-
The Automated Calculation of AF Cycle Length and Complexity Using a Novel EP Recording System
NCT05477602 ·Status: COMPLETED
-
PV-Isolation With the Cryoballoon Versus RF:a Randomized Controlled Prospective Non-inferiority Trial (FreezeAF)
NCT00774566 ·Status: COMPLETED ·Phase: PHASE4
-
Stereotaxis Study To Obliterate Persistent Ventricular Tachycardia
NCT00851279 ·Status: COMPLETED ·Phase: PHASE4
-
Left Atrial Appendage Closure Registry of Henri Mondor Hospital
NCT05565209 ·Status: RECRUITING
-
Registry on WATCHMAN Outcomes in Real-Life Utilization
NCT01972282 ·Status: COMPLETED
-
Electrophysiological Properties of the Pulmonary Veins
NCT00530608 ·Status: COMPLETED
-
Using Left Atrium Appendage Closure in NVAF Patients With High Risk of Ischemic Stroke
NCT04479722 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Use of a High Density Mapping System to Complete Wide Area Circumferential Ablation of the Pulmonary Veins and Avoid Ostial Segmental Ablation
NCT02917044 ·Status: TERMINATED ·Phase: NA
-
Vascular Closure With a Device Compared to Manual Compression After Atrial Fibrillation Ablation: The LockeT II Study
NCT06078735 ·Status: RECRUITING ·Phase: NA
-
Balloon Cryoablation Without Contrast
NCT04344743 ·Status: UNKNOWN ·Phase: NA
-
EXercise Cardiac Magnetic Resonance Assessment of Left Atrial Mechanics Following Ablation
NCT06212791 ·Status: RECRUITING
-
The Low Voltage Guided Ablation Trial of Persistent Atrial Fibrillation
NCT02732626 ·Status: COMPLETED ·Phase: NA
-
Pulmonary Vein Antrum Isolation (PVAI) Plus Scar Homogenization and Non-PV Triggers Ensure Long-term Recurrence-free Survival in Non-paroxysmal Atrial Fibrillation
NCT01672138 ·Status: UNKNOWN ·Phase: NA
-
Artificial Intelligence Mapping and Ablation of Non-Pulmonary Vein Electrical Drivers of AF Study
NCT06935591 ·Status: RECRUITING ·Phase: NA
-
Mesh Ablator Versus Cryoballoon Pulmonary Vein Ablation of Symptomatic Paroxysmal Atrial Fibrillation
NCT01061931 ·Status: TERMINATED ·Phase: PHASE4
-
ABLATE Versus PACE: PVI or AV Node Ablation and PM Implantation for Elderly Patients With Persistent AF
NCT04906668 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA