A Randomized Placebo-procedure Controlled Trial of the Enhancor System (PULmonary Artery Denervation) to Evaluate Safety and Efficacy in Patients With Combined Pre- and Post-capillary Pulmonary Hypertension Associated With Left Heart Disease
NCT07214376 · Status: NOT_YET_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 750
Last updated 2026-03-12
Summary
The goal of this clinical study is to evaluate the safety and efficacy of percutaneous pulmonary artery denervation with the Multi-Pole Pulmonary Artery Radiofrequency Ablation Enhancor System in patients with combined pre- and post-capillary pulmonary hypertension (CpcPH) associated with left heart disease (LHD). This randomized control trial will compare the investigational device (The Enhancor System) to control (medical therapy.)
Participants who will consist of patients with chronic heart failure (HF) who are receiving maximally tolerated guideline-directed medical therapy (GDMT) for left heart failure, are clinically stable, and who have been diagnosed with CpcPH by right heart catheterization (RHC), will be treated with PADN and followed for 3 years.
Conditions
- Pulmonary Hypertension
- Heart Failure With Reduced Ejection Fraction
- Hypertension
- Vascular Diseases
- Cardiovascular Diseases
- Heart Failure
- Heart Failure With Preserved Ejection Fraction
- Heart Failure With Mid Range Ejection Fraction
Interventions
- DEVICE
-
Pulmonary Artery Denervation (PADN)
In patients randomized to Intervention, a Contrast pulmonary artery (PA) angiography will be performed to identify the pulmonary artery bifurcation and measure the PA diameter. Once the anatomy is deemed suitable, a radiofrequency ablation catheter will be introduced into the ostium of the left PA and the distal bifurcation of the main PA. The catheter will be maneuvered within the PA to deliver energy circumferentially, ensuring tight electrode contact with the endovascular surface. Approximately three ablations will be performed at a target temperature of 50 °C (range 45-55 °C) for 120 seconds each at both the left PA ostium and the distal main PA bifurcation. All patients enrolled in this clinical study will following the Guideline-Directed Medical Therapy (GDMT)
- DEVICE
-
Sham procedure control
In patients randomized to a placebo-procedure, a script will be followed for approximately 20 minutes to simulate the PADN procedure. All patients enrolled in this clinical study will following the Guideline-Directed Medical Therapy (GDMT)
Sponsors & Collaborators
-
Pulnovo Medical, Inc.
lead INDUSTRY
Principal Investigators
-
Gregg W. Stone · Icahn School of Medicine at Mount Sinai
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- DOUBLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 85 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2026-04-01
- Primary Completion
- 2029-12-31
- Completion
- 2031-12-31
- FDA Device
- Yes
More Related Trials
-
Comparison of Different Pulsed Field Ablation Catheters in Atrial Fibrillation
NCT07036965 ·Status: RECRUITING ·Phase: NA
-
Catheter Denervation of Pulmonary Arteries in Treatment of IPAH & SPAH
NCT02403908 ·Status: UNKNOWN ·Phase: PHASE1
-
Prospective Evaluation of CT Guided Ablation of Cardiac Ganglionated Plexi
NCT04642976 ·Status: COMPLETED
-
The Effect of Pulse Field Ablation on Atrial Mechanics in Catheter Ablation of Paroxysmal Atrial Fibrillation
NCT06557876 ·Status: RECRUITING ·Phase: NA
-
Evaluation of the Safety, Feasibility and Usability of the EPD D700 System in Atrial Flutter Ablation Procedures
NCT02768051 ·Status: WITHDRAWN ·Phase: NA
-
HeartLight Ablation in Patients With Paroxysmal Atrial Fibrillation (PAF)
NCT01456000 ·Status: COMPLETED ·Phase: PHASE3
-
Using a Novel Balloon-shaped Large-Focal Pulsed Field Ablation Catheter in Persistent Atrial Fibrillation
NCT07294742 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Multi-electrode Radiofrequency Balloon Catheter Use for the Isolation of the Pulmonary Veins.
NCT03437733 ·Status: COMPLETED ·Phase: NA
-
PROTECT-PACE STUDY - The Protection of Left Ventricular Function During Right Ventricular Pacing
NCT00461734 ·Status: COMPLETED ·Phase: NA
-
Ablation of the Pulmonary Veins for Paroxysmal Afib
NCT00744874 ·Status: COMPLETED ·Phase: PHASE4
-
First in Man Study of Left Atrial Appendage Pulsed Field Ablation Occluder
NCT05731882 ·Status: RECRUITING ·Phase: NA
-
Post-Embolic Rhythm Detection With Implantable Versus External Monitoring
NCT02428140 ·Status: COMPLETED ·Phase: NA
-
A Study for Treatment of Paroxysmal Atrial Fibrillation (PAF) by Pulsed Field Ablation (PFA) System With Irreversible Electroporation (IRE)
NCT04524364 ·Status: COMPLETED ·Phase: NA
-
Unipolar Atrial Electrogram Modification Combined to the Contact Force Sensing Technology for Pulmonary Vein Isolation
NCT02520960 ·Status: COMPLETED
-
Low Voltage-Directed Catheter Ablation for Atrial Fibrillation
NCT03355456 ·Status: RECRUITING ·Phase: NA
-
The FARAPULSE ADVENT PIVOTAL Trial PFA System vs SOC Ablation for Paroxysmal Atrial Fibrillation
NCT04612244 ·Status: COMPLETED ·Phase: NA
-
Heart Rate Regularization in Atrial Fibrilation and Heart Failure
NCT05029570 ·Status: RECRUITING ·Phase: NA
-
Safety and Efficacy Study of the Combined Ablation Procedure to Treat Paroxysmal Atrial Fibrillation
NCT01103674 ·Status: TERMINATED ·Phase: NA
-
FIH Study of PFLotus in Persistent Atrial Fibrillation
NCT07301190 ·Status: RECRUITING ·Phase: NA
-
Single Center Pilot Study Using the ECGenius System to Collect Electrogram Data to Test an Ablation Impact Algorithm
NCT05458648 ·Status: COMPLETED
-
Use of a High Density Mapping System to Complete Wide Area Circumferential Ablation of the Pulmonary Veins and Avoid Ostial Segmental Ablation
NCT02917044 ·Status: TERMINATED ·Phase: NA
-
Non-invasive Characterization of the Mechanisms of Atrial Fibrillation Maintenance
NCT02497248 ·Status: COMPLETED
-
Safety, Performance, and Clinical Benefit of Pacing the Left Bundle Branch Area - Post-Market Clinical Follow-up
NCT07209852 ·Status: RECRUITING
-
Prophylactic Permanent Pacemaker in Patients With Right Bundle Branch Block Undergoing Transcatheter Aortic Valve Implantation
NCT05889208 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Clinical Value of Linear Ablation Without Pulmonary Vein Isolation in Persistent Atrial Fibrillation
NCT05468528 ·Status: UNKNOWN ·Phase: NA