Factors Associated With Response to Cardiac Resynchronization Therapy in Heart Failure Patients With Non-LBBB ECG Pattern
NCT06977217 · Status: ACTIVE_NOT_RECRUITING · Type: OBSERVATIONAL · Enrollment: 270
Last updated 2025-05-18
Summary
Cardiac resynchronization therapy with a defibrillator (CRT-D) in heart failure (HF) patients without left bundle branch block (non-LBBB) has been less beneficial to improve outcomes despite being a guideline indicated therapy, posing a significant treatment challenge. However, non-LBBB patients with echocardiography response to CRT-D have better outcomes, and pre-implant variables could predict response, identifying patients who benefit the most. In this study, we plan to enroll 270 HF patients with non-LBBB and guideline-indicated CRT-D implantation to validate our prior echocardiography predictor score, and to identify novel ECG and echocardiography predictors using conventional statistics and machine learning analysis. We will also assess the applicability of such a score for clinical outcomes of HF, ventricular arrhythmias, or death.
Conditions
- Cardiomyopathies
- Heart Failure
- Non-left Bundle Branch Block
- Cardiac Resynchronization Therapy
Interventions
- PROCEDURE
-
CRT-D implantation
Cardiac resynchronization therapy with a defibrillator (CRT-D). This combination device uses a pacemaker and an implantable cardioverter-defibrillator (ICD). It may be recommended for people with heart failure who also have a risk of sudden cardiac death. It can find dangerous heart rhythms and correct them. It can pace the heartbeat or shock the heart out of a dangerous heart rhythm.
Sponsors & Collaborators
-
University of Rochester
lead OTHER
Principal Investigators
-
Valentina Kutyifa, MD, PhD · University of Rochester
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2022-03-21
- Primary Completion
- 2026-06-30
- Completion
- 2026-06-30
Countries
- United States
Study Locations
More Related Trials
-
Non-Invasive Method for Evaluation of Cardiac Resynchronization Therapy
NCT05868616 ·Status: RECRUITING
-
Resynchronization in Paced Heart Failure Patients With Implantable Cardioverter Defibrillator (ICD) Indication
NCT01415024 ·Status: UNKNOWN ·Phase: PHASE4
-
Safety and Effectiveness of Left Bundle Branch Area Pacing Versus Conventional Cardiac Resynchronization Therapy in Heart Failure
NCT07069738 ·Status: RECRUITING ·Phase: NA
-
Predicting Response to Cardiac Resynchronization Therapy in Heart Failure
NCT00359372 ·Status: COMPLETED
-
Triple-site Biventricular Stimulation in the Optimization of CRT
NCT02350842 ·Status: COMPLETED ·Phase: NA
-
Effect of Targeting Left Ventricular Lead Position on the Rate of Response to Cardiac Resynchronization Therapy.
NCT00399594 ·Status: COMPLETED ·Phase: PHASE2/PHASE3
-
Narrow QRS HF Patients Assessed by ECG Belt
NCT03367104 ·Status: COMPLETED
-
Cardiac Resynchronization Therapy (CRT) Based Heart Failure Monitoring Study
NCT00632372 ·Status: COMPLETED
-
Response To Cardiac Resynchronization Therapy In Heart Failure: Role Of Arterial Stiffness
NCT00970476 ·Status: WITHDRAWN
-
Evolution of Intracardiac Electrograms Recorded by Left Bundle Branch Pacing Lead in Patients With ICD or CRT-D
NCT06745778 ·Status: RECRUITING
-
ECG Signal Collection From Long QT Syndrome, Wide QRS Complexes, Heart Failure, and Cardiac Resynchronization Patients
NCT00399412 ·Status: COMPLETED
-
Restoration of Chronotropic Competence in Heart Failure Patients With Normal Ejection Fraction
NCT00670111 ·Status: TERMINATED ·Phase: NA
-
Cardiac Resynchronisation Therapy In Patients With Heart Failure: Mechanistic Insights From Cardiac MRI And Electroanatomical Mapping
NCT04322877 ·Status: UNKNOWN ·Phase: NA
-
ECG Belt vs. Echocardiographic Optimization of CRT
NCT03305692 ·Status: COMPLETED ·Phase: NA
-
Predictives Factors of Cardiac Resynchronization Therapy: a Multimodal Analysis Using 2D Speckle Tracking Echocardiography Coupled With MIBG Myocardial Scintigraphy and Heart Failure Biomarkers
NCT02018029 ·Status: UNKNOWN
-
Biological Mechanisms Behind Resynchronization Therapy in Heart Failure
NCT06140914 ·Status: RECRUITING
-
Multipolar CRT-d and Diabetes
NCT03095196 ·Status: COMPLETED
-
Metabolic Mapping and Cardiac Resynchronization
NCT03420833 ·Status: COMPLETED ·Phase: NA
-
Dual-Site LV Pacing in CRT Non Responders: Multicenter Randomized Trial
NCT01059175 ·Status: COMPLETED ·Phase: NA
-
Optimal Coronary Sinus Lead Implantation Using Intracardiac Impedography and Magnetic Resonance Imaging
NCT01129635 ·Status: COMPLETED ·Phase: NA
-
CardioInsight 3 - LBBB
NCT05556018 ·Status: RECRUITING ·Phase: NA
-
Multi-lead ECG to Effectively Optimize Resynchronization Devices: New CRT Recipients
NCT04083690 ·Status: UNKNOWN ·Phase: NA
-
Ensure Cardiac Resynchronization Therapy Study
NCT00291564 ·Status: COMPLETED
-
Comparative Effectiveness of Prophylactic ICD Versus Non-ICD Therapy
NCT06543446 ·Status: TERMINATED ·Phase: NA
-
Combining Myocardial Strain and Cardiac CT to Optimize Left Ventricular Lead Placement in CRT Treatment
NCT01426321 ·Status: COMPLETED ·Phase: NA