Resynchronization in Paced Heart Failure Patients With Implantable Cardioverter Defibrillator (ICD) Indication
NCT01415024 · Status: UNKNOWN · Phase: PHASE4 · Type: INTERVENTIONAL · Enrollment: 30
Last updated 2011-08-11
Summary
Today patients with a Cardiac Resynchronization Therapy (CRT) indication usually receive 2 ventricular leads, right ventricular (RV) apex and left ventricular (LV) (postero-) lateral, gaining a responder rate of approximately 70%. However, the physiological agitation of the left ventricle takes place over two pathways. Therefore single point stimulation might be insufficient for a dilated, insufficiently and asynchronously contracting left ventricle, resulting in either insufficient or no response to the therapy.
In the "CRT ICD Dual LV" study the patients receive a second LV lead in an anterior vein. When this lead is placed, temporary dual LV stimulation is started. To assess the effectivity of the dual LV lead stimulation intraoperatively a LV dp/dt-pressure measurement is taken. If there is an increase in LV dp/dt, the patients will be stimulated with both leads permanently. If not they will be stimulated conventionally.
The patients participating in this study are monitored for 12 months after implantation.
Conditions
- Heart Failure
- Left Bundle-Branch Block
Interventions
- PROCEDURE
-
second LV lead in CRT
second LV lead in CRT
Sponsors & Collaborators
- collaborator INDUSTRY
-
Schuechtermann-Klinik
lead OTHER
Principal Investigators
-
Wolfgang Kranig, MD · Schuechtermann-Klinik
Study Design
- Allocation
- NON_RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Max Age
- 80 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2011-05-31
- Primary Completion
- 2012-05-31
Countries
- Germany
Study Locations
More Related Trials
-
Stimulus Intensity in Left Ventricular Leads
NCT01060449 ·Status: COMPLETED ·Phase: NA
-
Cardiac Magnetic Resonance GUIDEd Management of Mild-moderate Left Ventricular Systolic Dysfunction.
NCT01918215 ·Status: UNKNOWN ·Phase: NA
-
A Comparison of Two Techniques for Choosing the Best Place to Put a Pacing Lead for Cardiac Resynchronisation Therapy
NCT02061241 ·Status: COMPLETED
-
Next Generation INCEPTA Implantable Cardioverter Defibrillator (ICD) and Cardiac Resynchronization Therapy (CRT-D) Field Following Study
NCT01227785 ·Status: COMPLETED
-
Clinical Investigation of the Medtronic EnTrust™ Implantable Cardioverter Defibrillator (ICD), Model D153ATG
NCT00273195 ·Status: COMPLETED ·Phase: NA
-
Cardiac Resynchronization Therapy (CRT)-Narrow-dp/Dt-Study
NCT00821938 ·Status: COMPLETED ·Phase: PHASE4
-
Programming Implantable Cardioverter Defibrillators in Patients With Primary Prevention Indication
NCT00743522 ·Status: COMPLETED
-
Effect of Targeting Left Ventricular Lead Position on the Rate of Response to Cardiac Resynchronization Therapy.
NCT00399594 ·Status: COMPLETED ·Phase: PHASE2/PHASE3
-
Resynchronization/Defibrillation for Ambulatory Heart Failure Trial
NCT00251251 ·Status: COMPLETED ·Phase: NA
-
Monitoring of Hemodynamics in Heart Failure Patients by Intracardiac Impedance Measurement
NCT01711281 ·Status: COMPLETED ·Phase: PHASE4
-
Reverse Electrical Remodeling of Native Conduction in Cardiac Resynchronization Therapy
NCT01924221 ·Status: COMPLETED
-
Reduction of Inappropriate Implantable Cardioverter Defibrillator (ICD) Therapies in Primary Prevention Patients
NCT01217528 ·Status: COMPLETED ·Phase: NA
-
The REACT-ICD Trial
NCT02439424 ·Status: UNKNOWN ·Phase: PHASE1/PHASE2
-
Triple-site Biventricular Stimulation in the Optimization of CRT
NCT02350842 ·Status: COMPLETED ·Phase: NA
-
Electrophysiological Optimization of Left Ventricular Lead Placement in CRT
NCT02346097 ·Status: COMPLETED ·Phase: NA
-
Development and Validation of Performance Metrics for Cardiac Device Implant Procedures
NCT03577340 ·Status: UNKNOWN
-
Multi-lead ECG to Effectively Optimize Resynchronization Devices: New CRT Recipients
NCT04083690 ·Status: UNKNOWN ·Phase: NA
-
INvestigation on Routine Follow-up in CONgestive HearT FAilure Patients With Remotely Monitored Implanted Cardioverter Defibrillators (ICD) SysTems
NCT01200381 ·Status: COMPLETED ·Phase: NA
-
REsynchronization reVErses Remodeling in Systolic Left vEntricular Dysfunction (REVERSE)
NCT00271154 ·Status: COMPLETED ·Phase: NA
-
Bifocal Right Ventricular PAcing in Right Bundle Branch blocK and Heart Failure With Reduced Ejection Fraction. The Study Tests the Superiority of Right Ventricular Bifocal Stimulation Over VVI Implantable Defibrillator in Right Bundle Branch Block and Heart Failure.
NCT03524001 ·Status: TERMINATED ·Phase: NA
-
Implantable Cardioverter Defibrillators - Improving Risk Stratification
NCT01944514 ·Status: COMPLETED
-
Clinical and Device Functional Assessment of Real World ICD Patients
NCT02341768 ·Status: COMPLETED
-
Cardiac Resynchronization Therapy (CRT) and Left Ventricular Assist Devices (LVAD) Therapy
NCT02083419 ·Status: COMPLETED
-
B-Left HF: Biventricular Versus Left Univentricular Pacing With Implantable Cardiac Defibrillator (ICD) Back-Up in Heart Failure Patients
NCT00187213 ·Status: COMPLETED ·Phase: NA
-
Identification of the Pericardiophrenic Vein During Cardiac Device Implant Procedures to Prevent Extracardiac Stimulation
NCT01008670 ·Status: COMPLETED