Effect of Different Ventilation Modes on POCD in Elderly Patients with Abdominal Wall Hernia

NCT06764745 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 471

Last updated 2025-03-05

No results posted yet for this study

Summary

The purpose of this clinical trial is to understand the effect of different ventilation patterns during surgery on postoperative cognitive impairment in elderly patients with abdominal wall hernias. It will also explore how to reduce the incidence of postoperative cognitive impairment. The main questions it aims to answer are:

* Does the mode of ventilation affect the incidence of postoperative cognitive impairment in elderly patients?
* Does optic nerve sheath edema affect the incidence of postoperative cognitive impairment in elderly patients? Researchers will monitor patients with different ventilation patterns intraoperatively and investigate postoperatively to see if the ventilation pattern affects postoperative cognitive impairment.

Participants will:

* Randomly assigned to groups with different ventilation patterns
* Record various values during surgery by the researchers
* Presence of cognitive impairment assessed by cognitive scales after surgery

Conditions

  • Postoperative Cognitive Impairment
  • Optic Nerve Sheath Edema

Interventions

DEVICE

PC Ventilation Modes

Following induction, Group I patients received mechanical ventilation using the PC mode. The anesthetic machine (MAQUET Flow-I, Italy) parameters were set as follows: The inspiratory pressure (Pins) was adjusted to maintain an end-tidal carbon dioxide concentration (ETCO2) of 4.0-5.0 kPa. Pure oxygen and air were utilized at 0.3 L/min each, with an oxygen content of 41%. The positive end-expiratory pressure (PEEP) was set at 10 cmH2O, with an inspiration-to-expiration ratio of 1:2, a respiratory rate of 16 breaths per minute, and an oxygen content of 41%.

DEVICE

VC Ventilation Modes

Following induction, Group II patients received mechanical ventilation using the VC mode. The anesthetic machine (MAQUET Flow-I, Italy) parameters were set as follows: The inspiratory pressure (Pins) was adjusted to maintain an end-tidal carbon dioxide concentration (ETCO2) of 4.0-5.0 kPa. Pure oxygen and air were utilized at 0.3 L/min each, with an oxygen content of 41%. The positive end-expiratory pressure (PEEP) was set at 10 cmH2O, with an inspiration-to-expiration ratio of 1:2, a respiratory rate of 16 breaths per minute, and an oxygen content of 41%.

DEVICE

PRVC Ventilation Modes

Following induction, Group III patients received mechanical ventilation using the PRVC mode. The anesthetic machine (MAQUET Flow-I, Italy) parameters were set as follows: The inspiratory pressure (Pins) was adjusted to maintain an end-tidal carbon dioxide concentration (ETCO2) of 4.0-5.0 kPa. Pure oxygen and air were utilized at 0.3 L/min each, with an oxygen content of 41%. The positive end-expiratory pressure (PEEP) was set at 10 cmH2O, with an inspiration-to-expiration ratio of 1:2, a respiratory rate of 16 breaths per minute, and an oxygen content of 41%.

Sponsors & Collaborators

  • Inner Mongolia Baogang Hospital

    collaborator OTHER
  • The Affiliated Hospital of Inner Mongolia Medical University

    collaborator OTHER
  • Inner Mongolia University of Science and Technology

    lead OTHER

Study Design

Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
TRIPLE
Model
PARALLEL

Eligibility

Min Age
65 Years
Max Age
90 Years
Sex
ALL
Healthy Volunteers
Yes

Timeline & Regulatory

Start
2024-03-01
Primary Completion
2025-02-28
Completion
2025-02-28
FDA Device
Yes

Countries

  • China

Study Locations