Optimising Neonatal Ventilation with Closed-loop Oxygen Control

NCT05657795 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 40

Last updated 2025-03-10

No results posted yet for this study

Summary

Ventilated newborns frequently need supplemental oxygen but its use must be monitored carefully as both giving too much or too little oxygen can have harmful effects. Giving too little oxygen results to low oxygen levels (hypoxia) and increases the risk of complications and mortality. Excessive oxygen delivery (hyperoxia) increases the risk of diseases involving several organs such as the retinas and the lungs. Although infants born very preterm require support with their breathing more often, more mature neonates may also need to be ventilated at birth and to receive supplemental oxygen. Therefore, they may suffer from problems related to hypoxia and hyperoxia.

For the above reasons, oxygen levels are continuously monitored and the amount of oxygen provided is manually adjusted by the nurses and doctors.

Closed-loop automated oxygen control systems (CLAC) are a more recent approach that involves the use of a computer software added to the ventilator. This software allows for automatic adjustment of the amount of oxygen provided to the baby in order to maintain oxygen levels within a desired target range depending on the baby's age and clinical condition. Previous studies in preterm and very small infants showed that automated oxygen control systems provided the right amount of oxygen for most of the time and prevented hypoxia and hyperoxia with fewer manual adjustments required by clinical staff. Preliminary results from a study that included infants born at 34 weeks gestation and beyond showed that CLAC systems allowed to reduce the amount of supplementary oxygen more rapidly. With this study we aim to compare the time spent in hyperoxia and the overall duration of oxygen treatment between infants whose oxygen is adjusted either manually or automatically while they remain ventilated. This will help us understand if CLAC systems help reduce the complications related to oxygen treatment.

Conditions

  • Infant, Newborn, Diseases
  • Mechanical Ventilation Complication

Interventions

DEVICE

Closed-loop automated oxygen control (Oxygenie, SLE6000)

The OxyGenie closed-loop oxygen saturation monitoring software (SLE) uses oxygen saturations from the SpO2 probe attached to the neonate, fed into an algorithm, to automatically adjust the percentage of inspired oxygen to maintain oxygen saturations within the target range. Manual adjustments including the percentage of FiO2 will be allowed at any point during the study if deemed appropriate by the clinical team.

Sponsors & Collaborators

Principal Investigators

  • Theodore Dassios, PhD · King's College Hospital/ King's College London

Study Design

Allocation
RANDOMIZED
Purpose
OTHER
Masking
NONE
Model
PARALLEL

Eligibility

Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2022-12-07
Primary Completion
2024-06-30
Completion
2024-06-30

Countries

  • United Kingdom

Study Locations

More Related Trials

Entities

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT05657795 on ClinicalTrials.gov