Bioactive Restorative Material in Non-Carious Cervical Lesions
NCT05593159 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 30
Last updated 2024-02-28
Summary
Evaluating the clinical performance of a bioactive restorative materiel (Cention N) placed in non-carious cervical lesions (NCCLs) with no preparation and 1-step adhesive system or, with preparing a gingival retentive groove and no adhesive system.
Conditions
- Cervical Lesion
Interventions
- OTHER
-
Dentin Conditioning
After washing and drying -but not desiccating- Dentin Conditioner 20% (GC, Japan) will be applied using a cotton pellet for 20 seconds then rinsed thoroughly and gently dried
- OTHER
-
RM-GIC
RM-GIC (Fuji II LC) will be applied in \<2mm incremental layers afterword light-cured for 10 sec (1,000 mW/cm2) per increment to fill the cavity.
- OTHER
-
1-step adhesive
A universal adhesive system (Tetric® N-Bond Universal) will be applied on both enamel and dentin and gently scraped for 20 sec, then dispersed with oil-free gentle air stream, then light-cured for 10 sec (1,000 mW/cm2).
- OTHER
-
Cention N
The cavity will be restored using cention N followed by light curing for 10sec (1,000 mW/cm2)
- OTHER
-
Dentin roughness
Using a round carbide bur size 14/16, (H1SEM.204.014 VPE5 or H1SEM.204.016 VPE 5, Komet Dental, Lemgo, Germany) on a low-speed handpiece. (No bevel preparation will be made)
- OTHER
-
Gingival retentive groove preparation
Using size-010 round carbide bur (H1SEM.205.010 VPE 5, Komet Dental, Lemgo, Germany) on a low-speed handpiece.
Sponsors & Collaborators
-
Damascus University
lead OTHER
Principal Investigators
-
Hussam Milly, PhD · Milly
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- TRIPLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2022-05-15
- Primary Completion
- 2023-10-01
- Completion
- 2023-11-01
Countries
- Syria
Study Locations
More Related Trials
-
Clinical Performance of Adhesive Systems Containing HEMA and 10-MDP in Non Carious Cervical Lesions
NCT04756349 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Cervical Restorations Performance Using Modified Universal Adhesive
NCT05509127 ·Status: ACTIVE_NOT_RECRUITING ·Phase: PHASE1
-
Clinical Evaluation of Bulk-fill Alkasite Restoration Versus Resin Modified Glass Ionomer in Adult With Class V Carious
NCT04716517 ·Status: UNKNOWN ·Phase: NA
-
Evaluation of Adhering Flowable Composite With and Without Adhesive Vs Flowable in Cervical Lesions
NCT03859284 ·Status: UNKNOWN ·Phase: NA
-
Evaluation Of Clinical Performance of Self-adhering Flowable Composite vs Conventional Flowable Composite in Cervical Carious Lesions
NCT04475172 ·Status: UNKNOWN ·Phase: NA
-
Desensitizing Effect and Tooth Color Change After Using Giomer-based Varnish Versus Bioactive Glass Air Polishing in Treating Cervical Hypersensitive Lesions
NCT05981625 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Clinical Performance of ARS Containing Universal Adhesives in Carious Cervical Lesions
NCT06572124 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Dentin Treatments for Restorations of Cervical Lesions Non-Carious
NCT02434601 ·Status: UNKNOWN ·Phase: PHASE2/PHASE3
-
Comparative Evaluation of an Alkasite-based Restorative Material and Two Different Resin Composites
NCT06375837 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Clinical Performance of Onlay Restorations After Cervical Margin Relocation (CMR)
NCT06155773 ·Status: UNKNOWN ·Phase: NA
-
Effect of an Additional Hydrophobic Adhesive Layer Application on the Class V Composite Restorations
NCT05635981 ·Status: COMPLETED ·Phase: NA
-
Effectiveness of Resin-Based Desensitizer and Laser, Compared to Fluoride Varnish in Management of Dentine Hypersensitivity in Non-carious Cervical Lesions
NCT07113847 ·Status: ACTIVE_NOT_RECRUITING ·Phase: PHASE2/PHASE3
-
Effect of Diode Laser on Sensitive NCCLs Prior to Composite Restoration, Dentin Bonding, and Clinical Durability of Composite Restorations.
NCT05501691 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Reduced Dentin Etching Time Using Universal Adhesives in the Quality of Cervical Lesions Restorations
NCT06465849 ·Status: COMPLETED ·Phase: NA
-
Non-carious Cervical Lesions and Treatments
NCT03403088 ·Status: COMPLETED ·Phase: NA
-
HEMA-free Universal Adhesives for Restoring Non-carious Cervical Lesions
NCT05497583 ·Status: COMPLETED ·Phase: NA
-
Prevalence of Non-Carious Cervical Lesions in Patient With Gingival Recession and Associated Risk Factors
NCT05170529 ·Status: COMPLETED
-
Endocrowns in Anterior Teeth: Effect of Cementation Protocols and Restorative Materials on the Clinical Performance of the Restorations
NCT05973292 ·Status: COMPLETED ·Phase: PHASE2
-
Laser Etching Effect on Application Mode of Universal Adhesive
NCT04814836 ·Status: UNKNOWN ·Phase: NA
-
Investigation of Glass Carbomer Performance
NCT04127929 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Two Different Methods of Resin Composite Application In Class II Restorations
NCT02185573 ·Status: COMPLETED ·Phase: NA
-
Non-Carious Cervical Lesions Restorations Using Different Modes of Universal Adhesive
NCT06227715 ·Status: COMPLETED ·Phase: NA
-
Clinical Evaluation of Three Different Universal Adhesives in Non-carious Cervical Lesions
NCT03415412 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Retrospective Evaluation of RMGI/GI Class V Restorations
NCT04401618 ·Status: COMPLETED
-
Clinical Evaluation of Different Bioactive Restorative Materials for Cervical Carious in High Caries Risk Patients
NCT06736964 ·Status: ENROLLING_BY_INVITATION ·Phase: NA