A Sibling Oocyte Study- Comparison of ZyMotTM Microfluidics Device to Density Gradient for Sperm Selection During ICSI
NCT04818593 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 108
Last updated 2023-06-05
Summary
The primary objective of this study is to evaluate whether the percentage of good quality embryo formation following Intracytoplasmic Sperm Injection (ICSI) is improved with the use of ZyMot method of microfluidic sperm separation compared to density gradient.
Conditions
- ART
Interventions
- DEVICE
-
ZyMot Multi Sperm Separation Device (850 ul)
850 uL of untreated semen will be directly deposited into the inlet port of the ZyMotTM Multi device, followed by placement of 750 uL culture medium in the outlet port and throughout the upper collection chamber. The device will then be incubated in a humidified 37C CO2 incubator for 30 minutes. During incubation, the healthiest and most motile sperm will swim through the microporous filter and into the upper collection chamber, where they will be recovered via the outlet port. 500 uL of the sperm sample will be removed and placed in a separate tube for analysis and insemination.
- OTHER
-
Density Gradient Centrifugation
Density gradient centrifugation will be performed using a one-layer preparation of 90% Isolate in 15 mL conical tubes. Semen will be layered over 1 mL of gradient and then centrifuged for 15 min at 300xg. The supernatant will be removed and discarded. The sperm pellet will be washed by mixing with Multipurpose Handling Medium Complete and centrifuging the sample for 5 min at 400xg. After the wash, the supernatant is removed and discarded and the pellet is re-suspended in culture medium, assessed for sperm parameters, and held at room temperature until insemination.
Sponsors & Collaborators
- lead OTHER
Principal Investigators
-
Rani Fritz, DO, PhD · NYU Langone Health
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2021-06-18
- Primary Completion
- 2021-11-29
- Completion
- 2021-11-29
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
A Comparative Study of Sibling Oocytes: ICSI vs. the IMSI Sperm Selection Method
NCT03240276 ·Status: UNKNOWN ·Phase: NA
-
User Site Testing Study to Evaluate Usability of the Q300™ Device Under "Real-life Conditions" in a Reproductive Laboratory Environment Use
NCT06232720 ·Status: RECRUITING ·Phase: NA
-
Sperm Selection Using Microfluidic Technology
NCT04997070 ·Status: COMPLETED
-
Automated Sperm Selection
NCT05240469 ·Status: RECRUITING ·Phase: NA
-
Zona Pellucida Bound Sperm vs. Embryologist Selected Sperm for Intracytoplasmic Sperm Injection
NCT05859152 ·Status: COMPLETED ·Phase: NA
-
Prospective Sibling Oocyte Study of a New Method to Improve Embryo Development in IVF/ICSI Patients
NCT05680363 ·Status: COMPLETED ·Phase: NA
-
Microfluidics Versus Gradient Centrifugation Effect on Euploidy Rates
NCT04744025 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
SISTER: Sibling Oocyte Insemination With Frozen Sperm From Third Party Donors: Evaluation of Reproductive Techniques
NCT07175571 ·Status: RECRUITING ·Phase: NA
-
A Comparative Study of Sibling Oocytes: ICSI vs. the PICSI Sperm Selection Method
NCT03240302 ·Status: UNKNOWN ·Phase: NA
-
Sperm Selection and Embryo Development: Comparison of the Density Gradient Centrifugation and Microfluidic Chip Sperm Preparation Methods Sperm Selection and Embryo Development: Comparison of the Density Gradient Centrifugation and Microfluidic Chip Sperm Preparation Methods
NCT04962074 ·Status: COMPLETED ·Phase: NA
-
SprmPik AI Sperm Selection Study SiD, an Assistant for Sperm Selection During Intracytoplasmic Sperm Injection in Medically Assisted Reproduction: Effect on Fertilization, Blastocyst Formation, Early Pregnancy Loss, and Consistent Practice. A Prospective Pilot Study.
NCT06518928 ·Status: RECRUITING
-
Comparative Study of Three Different Embryo Transfer Media in ICSI Cycles
NCT02792673 ·Status: UNKNOWN ·Phase: NA
-
Comparing Two Different Embryo Transfer Catheters
NCT03161119 ·Status: UNKNOWN ·Phase: NA
-
Microfluidics Versus Density Gradient Centrifugation for Sperm Preparation in IVF
NCT07004309 ·Status: COMPLETED ·Phase: NA
-
Is There a Difference in Oocyte Quality? A Comparison of Two Aspiration Needle Gauges
NCT02749773 ·Status: UNKNOWN ·Phase: NA
-
Mechanical Stimulation Improve the Fertilization in ICSI Cycle
NCT03810001 ·Status: UNKNOWN ·Phase: NA
-
Sibling Oocyte Study of Medium for In Vitro Fertilization/Intracytoplasmic Sperm Injection (IVF/ICSI) With no Human Serum Albumine
NCT00541892 ·Status: WITHDRAWN ·Phase: PHASE2
-
Clinical Evaluation of a Tubal Selective Delivery System
NCT05775913 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
A New Micro Swim-up Procedure for Sperm Preparation in ICSI Treatment
NCT02672124 ·Status: UNKNOWN
-
Oocyte Cryopreservation: Evaluation of an Oocyte Freezing and Thawing Technique
NCT00713869 ·Status: UNKNOWN
-
Sperm Selection by Rheotaxis and Thermotaxis in In-Situ Handmade Microfluidics of Fluidic Walls in the Same ICSI Plate
NCT06243926 ·Status: RECRUITING
-
Scanning the Meiotic Spindle in Assisted Reproductive Techniques to Assess Oocyte Quality
NCT06539585 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Implantation Enhancement by Elective Cryopreservation of All Viable Embryos
NCT02148393 ·Status: COMPLETED ·Phase: NA
-
Study of Free DNA Content of Embryo Culture Medium as a Non-Invasive Tool for Embryo Assessment
NCT02480491 ·Status: COMPLETED
-
Sperm Micro-swim up Technique; Process and Select in the Same Dish: a Sibling-oocyte-split Design
NCT05113225 ·Status: COMPLETED ·Phase: NA