Closed-loop in Adults With T2D Not Requiring Dialysis

NCT04701424 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 30

Last updated 2022-05-31

No results posted yet for this study

Summary

The main objective of this study is to determine the efficacy, safety and utility of fully automated closed-loop glucose control in the home setting over an 8 week period in adults with type 2 diabetes (T2D). This study builds on previous and on-going studies of closed-loop systems that have been performed in Cambridge in adults with type 1 diabetes in the home setting, and in adults with type 2 diabetes in the inpatient setting.

This is an open-label, single centre, randomised, cross-over study, involving two home study periods during which glucose levels will be controlled either by a fully automated closed-loop system or by participants' usual insulin therapy in random order. Each treatment arm is 8 weeks long with a 2-4 week washout period between treatments. A total of up to 30 participants with T2D will be recruited through outpatient clinics to allow for 24 completed participants available for assessment.

Participants will receive appropriate training by the research team on the safe use of the study devices (insulin pump and continuous glucose monitoring (CGM) and closed-loop insulin delivery system). Participants in the control arm will continue with standard therapy and will wear a blinded CGM system.

The primary outcome is time spent with glucose levels in the target range between 3.9 and 10.0 mmol/L as recorded by CGM. Secondary outcomes are the time spent with glucose levels above and below target, as recorded by CGM, and other CGM-based metrics in addition to insulin requirements. Safety evaluation comprises the tabulation of severe hypoglycaemic episodes.

Conditions

Interventions

DEVICE

CamAPS HX Closed-loop

The CamAPS HX closed-loop system comprises: Dana insulin pump (Diabecare, Sooil, Seoul, South Korea) Dexcom G6 real-time CGM sensor (Dexcom, Northridge, CA, USA) An Android smartphone hosting CamAPS HX Application with the Cambridge model predictive control algorithm and communicating wirelessly with the insulin pump Glooko/Diasend cloud upload system to monitor CGM/insulin data.

OTHER

Multiple Daily Insulin Injections (Control)

Multiple Daily Insulin Injections with masked Dexcom G6 CGM sensor (Dexcom, Northridge, CA, USA)

Sponsors & Collaborators

Principal Investigators

  • Roman Hovorka, PhD · University of Cambridge

Study Design

Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Model
CROSSOVER

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2020-12-16
Primary Completion
2022-03-30
Completion
2022-03-30

Countries

  • United Kingdom

Study Locations

More Related Trials

Entities

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT04701424 on ClinicalTrials.gov