Insulin Pump Versus Full Closed-loop for Type 2 Diabetes
NCT06959797 · Status: NOT_YET_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 80
Last updated 2025-05-07
Summary
The aim of the study is to compare, in a population of patients with type 2 diabetes, open-loop insulin pump treatment with the CamAPS HX (Camdiab) Fully Closed Loop Automated Insulin Therapy system, on the efficacy and safety of use of the Fully Closed Loop, as well as on psycho-social criteria of device acceptability, quality of life and diabetes burden. This is an open, multi-center, randomized, cross-over study, based on several observational or controlled trials carried out in Cambridge by Prof. Hovorka's team (see paragraph 4 below). The study will comprise a run-in phase followed by a 1st sequence in which randomized patients will use the Ypsomed pump (Ypsomed) and the FreeStyle Libre 3 sensor in open loop for 12 weeks Versus the Ypsomed pump (Ypsomed) coupled with the CamAPS HX algorithm and the FreeStyle Libre 3 sensor in full closed loop. At the end of this 1ère sequence, all patients will undergo a 2-4 week washout, during which they will use the Ypsomed pump and the FreeStyle Libre 3 sensor in open loop, and then in the 2nd sequence of the study, patients will switch to the other treatment for a further 12 weeks. A total of 80 patients on insulin pumps for at least 6 months will be recruited from 9 French centers. All patients will receive training in the use of the Ypsomed pump, the FreeStyle Libre 3 sensor and the CamAPS HX algorithm. The primary objective is Time on Target 70-180 mg/dl of 24h measured during the 12 weeks of each therapeutic period. Secondary objectives will be Time in Target 70-180 mg/dl day and night, Time above Target \> 180 mg/dl and \> 250 mg/dl, Time below Target \< 70 mg/dl and \< 54 mg/dl, time in the narrow target range 70-140 mg/dL, mean 24h blood glucose and glycemic variability measured over the 12 weeks of each treatment sequence, HbA1c, weight, total insulin dose and psychosocial endpoints assessed at the start and end of each treatment sequence. Safety data studied will include diabetes-related adverse events (ketoacidosis, symptomatic and severe hypoglycemia) and medical device-related adverse events (pump and sensor).
Conditions
Interventions
- DEVICE
-
Closed loop
Ypsomed pump (Ypsomed), CamAPS HX application activated, Android smartphone. Freestyle 3 sensors (Abbott)
- DEVICE
-
Open loop
Ypsomed pump (Ypsomed). Android smartphone. Freestyle 3 sensors (Abbott)
Sponsors & Collaborators
- collaborator INDUSTRY
-
Ypsomed Diabetes Care AG
collaborator INDUSTRY -
University Hospital, Caen
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- CROSSOVER
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2025-05-05
- Primary Completion
- 2027-12-31
- Completion
- 2028-12-31
Countries
- France
Study Locations
More Related Trials
-
Closing the Loop in Adults With Type 1 Diabetes (CLEAR)
NCT04977908 ·Status: COMPLETED ·Phase: NA
-
Closing the Loop in Adults With Type 1 Diabetes
NCT00910767 ·Status: COMPLETED ·Phase: NA
-
Closed-loop Insulin Delivery in the General Ward
NCT01774565 ·Status: COMPLETED ·Phase: NA
-
Closing the Loop in Adults With Type 1 Diabetes and HbA1C<7.5% Under Free Living Conditions
NCT02727231 ·Status: COMPLETED ·Phase: NA
-
Closed Loop From Onset in Type 1 Diabetes
NCT02871089 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Closed-loop Control of Glucose Levels (Artificial Pancreas) for 24 Hours in Adults With Type 2 Diabetes Under Intensive Insulin Therapy
NCT02490085 ·Status: COMPLETED ·Phase: PHASE2
-
Closing the Loop in Adults With Sub-optimally Controlled Type 1 Diabetes Under Free Living Conditions
NCT01961622 ·Status: COMPLETED ·Phase: NA
-
Closed-loop Control of Glucose Levels (Artificial Pancreas) for 12 Days in Adults With Type 1 Diabetes
NCT02846831 ·Status: COMPLETED ·Phase: PHASE2
-
taRgeting bEtA-Cell Function To achIeVe Remission of Type 2 diAbeTEs
NCT06844539 ·Status: RECRUITING ·Phase: NA
-
Closed-loop Control of Glucose Levels (Artificial Pancreas) for 15 Weeks in Adolescents and Adults With Type 1 Diabetes
NCT02846857 ·Status: WITHDRAWN ·Phase: PHASE2
-
Closing the Loop in Adolescents During Non-compliance Behaviours
NCT01629277 ·Status: COMPLETED ·Phase: PHASE2
-
Closing the Loop in Adults With Type 1 Diabetes in the Home Setting
NCT01440140 ·Status: COMPLETED ·Phase: PHASE2
-
The Impact of Hybrid Closed-loop Insulin Delivery in Type 1 Diabetes on Glycemic Control and PROMs
NCT04414280 ·Status: ACTIVE_NOT_RECRUITING
-
Feasibility Study to Evaluate the Hybrid-Logic Closed Loop System in Type 1 Diabetes
NCT02692547 ·Status: WITHDRAWN ·Phase: NA
-
Multiday Fully Closed Loop Insulin Delivery in Monitored Outpatient Conditions
NCT02127827 ·Status: UNKNOWN ·Phase: NA
-
Real-life Data From Diabetic Patients on Closed-loop Pumps
NCT05418699 ·Status: COMPLETED
-
Loop T2D Observational Study
NCT05951569 ·Status: COMPLETED
-
Closed-loop Control of Glucose Levels (Artificial Pancreas) for 5 Days in Adults With Type 1 Diabetes
NCT02488616 ·Status: WITHDRAWN ·Phase: PHASE2
-
Android Artificial Pancreas System (Android APS) Versus Control-IQ
NCT05165615 ·Status: UNKNOWN ·Phase: NA
-
Closing the Loop in Adults With Type 1 Diabetes Under Free Living Conditions
NCT04055480 ·Status: COMPLETED ·Phase: NA
-
Hybrid Closed Loop Pivotal Trial in Type 1 Diabetes
NCT02463097 ·Status: COMPLETED ·Phase: NA
-
Real-life Follow-up of the Physical Activity in Type 1 Diabetes Participants Equipped With an Insulin Pump With Hybrid Closed Loop
NCT07015970 ·Status: COMPLETED
-
Clinical Utility of Tight Objectives of Advanced Hybrid Closed-loop Systems Among Type 1 Diabetes Patients (TightT1AHCL)
NCT06466967 ·Status: COMPLETED
-
The Performance of an Artificial Pancreas at Home in People With Type 1 Diabetes
NCT02040571 ·Status: COMPLETED ·Phase: NA
-
Clinical Assessment of a Closed-loop Insulin Delivery System
NCT01534013 ·Status: COMPLETED ·Phase: NA