Safety and Effectiveness Study of a Closed Loop System Maintaining Patients' Glucose Levels During an Overnight Period
NCT01712594 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 9
Last updated 2017-05-12
Summary
Currently, patients diagnosed with type 1 diabetes rely on either finger stick or sensor glucose readings when making their insulin dosage decisions. Designing a computerized system that mimics the way insulin is produced naturally in a person who does not have type 1 diabetes holds many challenges; all of which cannot be addressed in just one study. The purpose of the Medtronic Overnight Closed Loop study is to assess the performance of a system designed to automatically infuse the correct insulin dose during the hours that the patient is sleeping.
The system consists of an insulin pump that provides insulin to the patient through an infusion set. A sensor inserted just under the patient's skin measures glucose levels and a transmitter sends this information to the pump. To enable the sensor to register the glucose information correctly, it must be set (calibrated) by a finger stick blood glucose 3-4 times a day. In the commercially released system, the physician would recommend the continuous background (basal) insulin rates and the patient would be required to make decisions regarding extra insulin (bolus) for meals or as a response to high glucose levels.
In the Closed Loop System, a mobile control system is added to these devices. This consists of an Android phone, a closed loop algorithm and a translator. This system is designed to translate the sensor information and direct the pump to provide the required dosage of insulin automatically without requiring input from the patient.
Reliable calibration has proved challenging, and so it is important that the system function safely, even when calibration is inaccurate. In this study, a calibration error will be introduced under very controlled circumstances. This testing will identify if the system can maintain acceptable overnight glucose levels, regardless of whether or not calibration is ideal.
Conditions
Interventions
- DEVICE
-
Closed Loop Procedure (Medtronic)
The procedure A is the device running under normal conditions, procedure B will incorporate an induced calibration error.
Sponsors & Collaborators
-
Medtronic Diabetes
lead INDUSTRY
Study Design
- Allocation
- NON_RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- CROSSOVER
Eligibility
- Min Age
- 18 Years
- Max Age
- 70 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2013-05-31
- Primary Completion
- 2013-12-31
- Completion
- 2014-12-31
- FDA Device
- Yes
Countries
- United Kingdom
Study Locations
More Related Trials
-
Hybrid Closed Loop Insulin Delivery System in Hypoglycemia
NCT03215914 ·Status: COMPLETED ·Phase: NA
-
Closed-loop Control of Glucose Levels (Artificial Pancreas) for 24 Hours in Adults With Type 2 Diabetes Under Intensive Insulin Therapy
NCT02490085 ·Status: COMPLETED ·Phase: PHASE2
-
Closing the Loop in Adults With Type 1 Diabetes
NCT00910767 ·Status: COMPLETED ·Phase: NA
-
Multiday Fully Closed Loop Insulin Delivery in Monitored Outpatient Conditions
NCT02127827 ·Status: UNKNOWN ·Phase: NA
-
Closing the Loop for 36 Hours in Adolescents With Type 1 Diabetes
NCT01074801 ·Status: COMPLETED ·Phase: PHASE2
-
Closing the Loop for 36 Hours in Adolescents With Type 1 Diabetes: Evaluation of Reduced Meal Bolusing
NCT01629251 ·Status: COMPLETED ·Phase: PHASE2
-
Closed-loop Insulin Delivery in the General Ward
NCT01774565 ·Status: COMPLETED ·Phase: NA
-
Day and Night Closed-loop in Young People With Type 1 Diabetes
NCT02925299 ·Status: COMPLETED ·Phase: NA
-
Home Testing of Day and Night Closed Loop With Pump Suspend Feature
NCT02523131 ·Status: COMPLETED ·Phase: NA
-
Automated Closed-loop in Children and Adolescents With Type 1 Diabetes
NCT02129868 ·Status: COMPLETED ·Phase: NA
-
ADvanced Hybrid Closed Loop Study in Adult Population With Type 1 Diabetes
NCT04235504 ·Status: COMPLETED ·Phase: NA
-
A Monocenter, Open-Label Glucose Clamp Study Examining the Metabolic Effect of Insulin Infusion Intervals for Basal Insulin Infusion in Patients With Type I Diabetes
NCT00772356 ·Status: COMPLETED ·Phase: NA
-
Medtronic Minimed Overnight Closed-Loop System
NCT01881009 ·Status: COMPLETED ·Phase: NA
-
Efficacy of Closed-loop Insulin Therapy in Adults Prone to Hypoglycemia
NCT04266379 ·Status: UNKNOWN ·Phase: NA
-
Closed-loop Glucose Control for Automated Management of Type 1 Diabetes
NCT00811317 ·Status: COMPLETED ·Phase: NA
-
Closing the Loop 24/7 in Adolescents With Type 1 Diabetes
NCT01873066 ·Status: COMPLETED ·Phase: NA
-
Closing the Loop in Children and Adolescents With Type 1 Diabetes in the Home Setting
NCT01778348 ·Status: COMPLETED ·Phase: PHASE2
-
Closing the Loop in Adults With Type 1 Diabetes in the Home Setting
NCT01440140 ·Status: COMPLETED ·Phase: PHASE2
-
Adolescence and Diabetes:Can an Automated Closed Loop System Improve Control ?
NCT03300934 ·Status: COMPLETED ·Phase: NA
-
Closed Loop Insulin Therapy in Type 1 Diabetics Based on Blood Microdialysis, Online Sensors and an eMPC Algorithm
NCT00535483 ·Status: COMPLETED
-
Glucose Counterregulation in Long Standing Type 1 Diabetes
NCT01474889 ·Status: COMPLETED ·Phase: NA
-
AHCL System Initiation in T1D Patients naïve to Technology
NCT04616391 ·Status: UNKNOWN ·Phase: NA
-
Closed-loop Control of Glucose Levels (Artificial Pancreas) for 5 Days in Adults With Type 1 Diabetes
NCT02488616 ·Status: WITHDRAWN ·Phase: PHASE2
-
Clinical Assessment of a Closed-loop Insulin Delivery System
NCT01534013 ·Status: COMPLETED ·Phase: NA
-
Impact of Hybrid Closed Loop Systems in People With Type I Diabetes
NCT05348499 ·Status: UNKNOWN