Summary
The main objective of this study is to determine the efficacy, safety and utility of fully closed-loop glucose control in the home setting in adults with type 2 diabetes (T2D). This study builds on previous and on-going studies of closed-loop systems that have been performed in Cambridge in adults with type 2 diabetes in the inpatient and in the home setting and in children and adults with type 1 diabetes.
This is an open-label, multi-national, multi-centre, randomised, single-period parallel study, involving a run-in period followed by a 26-week intervention period during which glucose levels will be controlled either by a fully closed-loop system or by participants usual insulin therapy with continuous glucose monitoring. A total of up to 224 adults with type 2 diabetes using insulin will be recruited through outpatient diabetes clinics, primary care centres, social media advertising and other established methods at participating centres. Participants will receive appropriate training in the safe use of the study devices.
The primary outcome is the between group difference in HbA1c at 26 weeks. Other key outcomes include the time spent with glucose levels within, above and below the target glucose range (3.9-10.0mmol/L) and mean sensor glucose as recorded by CGM over the 26 weeks. Insulin requirements, body weight, renal and liver function will also be compared. Safety evaluation comprises severe hypoglycaemic episodes, and other adverse and serious adverse events. Human factors outcomes include CGM \& closed-loop usage, questionnaires and semi-structured interviews.
Conditions
- Type 2 Diabetes Treated With Insulin
Interventions
- DEVICE
-
CamAPS HX
The automated closed loop system (CamAPS HX) will consist of: YpsoPump insulin pump Freestyle Libre 3 glucose sensor Smartphone hosting CamAPS HX app with the Cambridge model predictive control algorithm
- OTHER
-
Standard insulin therapy with glucose sensor
Participants usual insulin therapy with Freestyle Libre 3 glucose sensor
Sponsors & Collaborators
-
University of Edinburgh
collaborator OTHER -
Jaeb Center for Health Research
collaborator OTHER -
Swansea University
collaborator OTHER - lead OTHER
Principal Investigators
-
Roman Hovorka · University of Cambridge
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2024-12-06
- Primary Completion
- 2027-03-31
- Completion
- 2027-07-31
Countries
- Australia
- Austria
- Czechia
- France
- Switzerland
- United Kingdom
Study Locations
More Related Trials
-
Closed-loop Insulin Delivery in the General Ward
NCT01774565 ·Status: COMPLETED ·Phase: NA
-
Closing the Loop in Adults With Type 1 Diabetes in the Home Setting
NCT01440140 ·Status: COMPLETED ·Phase: PHASE2
-
Closing the Loop in Adults With Type 1 Diabetes (CLEAR)
NCT04977908 ·Status: COMPLETED ·Phase: NA
-
taRgeting bEtA-Cell Function To achIeVe Remission of Type 2 diAbeTEs
NCT06844539 ·Status: RECRUITING ·Phase: NA
-
Closing the Loop in Adults With Type 1 Diabetes
NCT00910767 ·Status: COMPLETED ·Phase: NA
-
Closing the Loop in Adults With Type 1 Diabetes and HbA1C<7.5% Under Free Living Conditions
NCT02727231 ·Status: COMPLETED ·Phase: NA
-
Closed Loop From Onset in Type 1 Diabetes
NCT02871089 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Closing the Loop in Adults With Type 1 Diabetes Under Free Living Conditions (AP@Home04_Phase 4)
NCT05257460 ·Status: COMPLETED ·Phase: NA
-
Closing the Loop in Adults With Sub-optimally Controlled Type 1 Diabetes Under Free Living Conditions
NCT01961622 ·Status: COMPLETED ·Phase: NA
-
Closing the Loop in Adolescents During Non-compliance Behaviours
NCT01629277 ·Status: COMPLETED ·Phase: PHASE2
-
The Performance of an Artificial Pancreas at Home in People With Type 1 Diabetes
NCT02040571 ·Status: COMPLETED ·Phase: NA
-
Impact of Hybrid Closed Loop Systems in People With Type I Diabetes
NCT05348499 ·Status: UNKNOWN
-
Choices and Experiences Around Closed-loop Therapy in Type 1 Diabetes
NCT07177404 ·Status: COMPLETED
-
Closing the Loop for 36 Hours in Adolescents With Type 1 Diabetes
NCT01074801 ·Status: COMPLETED ·Phase: PHASE2
-
The Impact of Hybrid Closed-loop Insulin Delivery in Type 1 Diabetes on Glycemic Control and PROMs
NCT04414280 ·Status: ACTIVE_NOT_RECRUITING
-
Short Term Closed-loop Glucose Control in Adults With Type 1 Diabetes
NCT01666028 ·Status: COMPLETED ·Phase: PHASE2
-
Closed-loop Control of Glucose Levels (Artificial Pancreas) for 12 Days in Adults With Type 1 Diabetes
NCT02846831 ·Status: COMPLETED ·Phase: PHASE2
-
Closed-loop for People Living With Cystic Fibrosis Related Diabetes
NCT05562492 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Real-life Data From Diabetic Patients on Closed-loop Pumps
NCT05418699 ·Status: COMPLETED
-
Closed-loop Control of Glucose Levels (Artificial Pancreas) for 24 Hours in Adults With Type 2 Diabetes Under Intensive Insulin Therapy
NCT02490085 ·Status: COMPLETED ·Phase: PHASE2
-
Clinical Utility of Tight Objectives of Advanced Hybrid Closed-loop Systems Among Type 1 Diabetes Patients (TightT1AHCL)
NCT06466967 ·Status: COMPLETED
-
Closing the Loop in Adults With Type 1 Diabetes Under Free Living Conditions
NCT04055480 ·Status: COMPLETED ·Phase: NA
-
Automated Closed-loop in Children and Adolescents With Type 1 Diabetes
NCT02129868 ·Status: COMPLETED ·Phase: NA
-
User Evaluation of the MiniMed 620G and 640G Insulin Pumps
NCT01726621 ·Status: COMPLETED ·Phase: NA
-
Closed-loop Control of Glucose Levels (Artificial Pancreas) for 5 Days in Adults With Type 1 Diabetes
NCT02488616 ·Status: WITHDRAWN ·Phase: PHASE2