Summary
Surgery for abdominal aortic pathology usually occurs in the setting of advanced cardiovascular disease. The repair can be relatively simple or complex with multiple steps including open repair, placing a stent with a catheter, and placing a complicated stent that allows for crossing vessels without occluding them. All these repairs require imaging follow up. The most commonly accepted tool for follow up is Computed Tomography (CT) scan which involves ionizing radiation and potentially nephrotoxic iodinated contrast. Recommendations for the time interval for follow up, as well the radiology imaging technique vary. Routine ultrasound with Doppler, CT, and MRI has all been employed utilizing various imaging protocols. Clinicians use non-contrast CT, arterial phase and delayed phase CT, ultrasound, and various combinations based on personal experience and patient pathology. Concerns over cost, potential nephrotoxicity of contrast agents and repeated radiation exposure has led to investigation of alternate imaging modalities such as contrast-enhanced ultrasound (CEUS). CEUS represents an improvement of ultrasound imaging but comparisons against CT report widely varying results, likely due to technical factors of CEUS and limitations of single-phase CTA. Contrast ultrasound has been used effectively to diagnose leaks in the aorta post repair and is without the radiation and potential nephrotoxicity of iodinated contrast. Of yet, no large prospective studies have compared CT and contrast US and no studies have looked at the more complicated staged or fenestrated repairs. This study proposes to perform a contrast ultrasound at the same time as a contrast CT using a standardized protocol. This protocol would include a non-contrast CT, angiographic CT, and a CT in a delayed phase in all patients as standard of care. We will compare the results of a contrast US with the various data derived from a three phase CT.
Conditions
- Abdominal Aortic Aneurysm
Interventions
- DIAGNOSTIC_TEST
-
Contrast enhanced ultrasound
CEUS involves the use of microbubble contrast agents and specialized imaging techniques to enhance the signal from blood, thus showing flow in macroscopic vessels as well as tissue perfusion information
Sponsors & Collaborators
-
University of Southern California
lead OTHER
Principal Investigators
-
Edward Grant · University of Southern California
Study Design
- Allocation
- NA
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2020-12-31
- Primary Completion
- 2022-12-31
- Completion
- 2023-07-31
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
Vector Velocity Imaging in AAA Patients
NCT05841524 ·Status: ACTIVE_NOT_RECRUITING
-
Development of Ultra-Low Dose CT Based Screening for Aortic Aneurysms
NCT03479164 ·Status: COMPLETED ·Phase: NA
-
Contrast Enhanced Ultrasound, Endoleak Detection Following EVAR v1.3
NCT02688751 ·Status: COMPLETED
-
Computed Tomography Scan Versus Color Duplex Ultrasound for Surveillance of Endovascular Repair of Abdominal Aortic Aneurysm. A Prospective Multicenter Study
NCT01230203 ·Status: COMPLETED ·Phase: NA
-
Follow-up After Endovascular Repair of Abdominal Aortic Aneurysm
NCT00488943 ·Status: UNKNOWN
-
Image Fusion of Preprocedural CTA With Real Time Fluoroscopy to Enhance EVAR Repair
NCT02295137 ·Status: UNKNOWN ·Phase: PHASE1
-
Abdominal Compartment Syndrome and Ruptured Aortic Aneurysm : Validation of a Predictive Test
NCT02859662 ·Status: UNKNOWN
-
Abdominal Aortic Aneurysm Follow-up After Endovascular Repair by Non-invasive Vascular Elastography
NCT01907386 ·Status: COMPLETED ·Phase: NA
-
Development of Novel Imaging Markers Predicting the Progression of Abdominal Aortic Aneurysm Using 3D Computed Tomography
NCT04333641 ·Status: COMPLETED
-
Prospective, Non-Randomized Evaluation of Carbon Dioxide Gas as a Contrast Agent in Comparison With Iodinated Contrast in Endovascular Aneurysm Repair
NCT00520416 ·Status: COMPLETED
-
Ultrasound Velocimetry in the Abdominal Aorta Before and After Endovascular Aneurysm Repair
NCT05148988 ·Status: COMPLETED
-
Coronary CT Angiography in Aneurysms Repaired With Open or Endovascular Approach
NCT01211548 ·Status: COMPLETED
-
Concordance of Three Imaging Methods by Dynamic CT, Contrast Ultrasound and CT Angiography in the Characterization of Endoleaks in Patients With an Aortic Endoprosthesis
NCT06318780 ·Status: RECRUITING ·Phase: NA
-
Non Invasive Imaging of Abdominal Aorta Aneurysm Hemodynamics and Wall Structure
NCT01104688 ·Status: COMPLETED
-
Cost-utility Analysis of Fenestrated Aortic Stents Versus Open Surgery for the Treatment of Complex Abdominal Aortic Aneurysms
NCT04671732 ·Status: COMPLETED
-
Efficacy of Biomarkers and CEUS Versus CTA in AAA Follow-up Post-EVAR
NCT06866769 ·Status: RECRUITING
-
Screening for Abdominal Aortic Aneurysms in the General Practice by Ultraportable Ultrasound
NCT05617326 ·Status: RECRUITING ·Phase: NA
-
Transthoracic Ultrasound Evaluation of Thoracic Aortic Aneurysms
NCT05137366 ·Status: UNKNOWN
-
Impact of Grafts and Endografts for Abdominal Aneurysms on Arterial Stiffness.
NCT02642952 ·Status: COMPLETED
-
Endoprosthesis Treatment Effects on Human Abdominal Aorta Aneurysms (AAA) Metabolic Activity
NCT01253252 ·Status: COMPLETED ·Phase: NA
-
Total Laparoscopic Versus Open Aortic Surgery for Abdominal Aortic Disease
NCT02325700 ·Status: COMPLETED
-
Tonometry and Duplex Ultrasound to Predict AAA Progression and CV Events in Aneurysm Patients (1-2-3 Trial)
NCT03989011 ·Status: COMPLETED
-
Using US to Evaluate Aortic Aneurysm Size Based on 3D Co-registration to Previous CT Scan
NCT02717481 ·Status: UNKNOWN
-
Tonometry(1) and Duplex Ultrasound(2) to Predict CV Events in to be Treated Patients With an AAA
NCT04183426 ·Status: RECRUITING
-
Ultra-low Dose Contrast for Endovascular Procedures
NCT06835127 ·Status: COMPLETED