Interest of a Post-operative Ultrasound With Systematic Use of Ultrasonic Contrast in the Follow-up of Aortic Endoprosthesis: Prospective Study at the University Hospital of Nice

NCT04196543 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 40

Last updated 2026-03-24

No results posted yet for this study

Summary

This is a prospective study conducted on a population with an aortic endoprosthesis in the context of an abdominal aortic aneurysm. The study's objective is to standardize the ultrasound methodology in the monitoring of aortic endoprosthesis in immediate post-operative care by comparing the results with CT-scan (gold standard). To improve ultrasound methodology, the investigators propose to use the VESMA protocol for ultrasound diameter measurement at four incidences. In addition, the use of ultrasonic contrast agents increases the accuracy of vascular structures, the quality of the ultrasound blood flow image and the duration of signal enhancement. This makes it possible to visualize small gauge vessels and those with slow flows. In this way, the investigators could improve the ultrasound technique for measuring aneurysm bag diameters and endoleak detection. Moreover, the toxicity of iodinated contrast agents is the third cause of acute renal failure in hospitalized patients and is all the more frequent when the investigators increase injections. Improving the quality of ultrasound investigations for the monitoring of aortic endoprosthesis would therefore allow us to reduce the number of CT-scan performed in this population and thus reduce irradiation and the injection of nephrotoxic products. Thereby, the investigators would like to integrate the technique into the systematic follow-up of patients who have benefited from the placement of an aortic endoprosthesis by replacing the CT-scan.

Conditions

  • Aneurysm, Abdominal Aortic

Interventions

OTHER

écho-doppler with ultrasonar Sonovue® injection

During this unique visit they will benefit from 2 imaging exams performed by two different operators: * Echo-doppler without "standard method" contrast injection (common practice) * An echo-doppler with Sonovue® ultrasound injection "Ultra\_evar method" (2.5 ml bolus 2-3 seconds) During this examination, the endoprosthesis and the aneurysm sac will be scanned according to the 4 incidences described above in order to objective whether or not there is a endoleak. The patient then performs the control CT-scan prior to discharge from hospital. The results of the medical imaging exams will be communicated to them before the hospital discharge, once the CT-scan has been performed. A cross-review of the studies will be performed later.

Sponsors & Collaborators

  • Centre Hospitalier Universitaire de Nice

    lead OTHER

Principal Investigators

  • Pascal GIORDANA, MD · Centre Hospitalier Universitaire de Nice

Study Design

Allocation
NA
Purpose
OTHER
Masking
NONE
Model
SINGLE_GROUP

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2020-02-28
Primary Completion
2021-12-10
Completion
2022-12-10

Countries

  • France

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.