Fusion of CT Angiography With 3D Contrast Ultrasound as a Method for Follow up for Endovascular Aneurysm Repair
NCT04089241 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 20
Last updated 2020-09-09
Summary
Abdominal Aortic Aneurysm (AAA) is a known vascular entity that may be life threatening condition .The most common treatment approach nowadays is the endovascular approach, a procedure known as endovascular aortic repair (EVAR). The most common procedure related complication is the expansion of the aneurysm from a "feeding vessel", usually a lumbar or intercostal artery. Another known complication is an endoleak from the stentgraft.Today, accepted EVAR follow up protocol consists of one multiple multiphasic CT angiography (CTA) scan, one month after the procedure and ultrasound exams there after . Ultrasonography is a useful method for detection and evaluation of AAA, has no ionizing radiation and is useful for the dynamic estimation of the aortic width in patients post EVAR. However, the sensitivity of ultrasonography solely for detection of endoleaks in post EVAR patients is not high.In recent years, the development of "fusion" applications allows the dual modality merge between ultrasound and CT scans that can be used as follow up examinations of known imaging findings on CT .Another application that had been developed for ultrasound machines is the ability to generate a 3 dimensional (3D) reconstruction which allows more precision. In the recent year the usage of intravenous contrast agent for ultrasonography based on microbubbles (BRACO SONOVIEW) has been approved by the Israeli ministry of health. This contrast agent is not nephrotoxic and the risk for allergic reaction is very low statistically similar to Gadolinium.A 3D contrast enhanced ultrasonography "fused" together with CTA may be a helpfull addition , which lacks radiation and odine contrast reactions and nephrotoxicity ,in the follow up in post EVAR patients , by means of identifing endoleaks at an earlier stage than by ultrasound alone. The purpose of our research is to evaluate the combined modality (fusion of CTA with CEUS) mentioned above in identifing early endoleaks in post EVAR patients and thus enabilng early intervention when needed
Conditions
- Abdominal Aortic Aneurysm
- Endoleak
Interventions
- OTHER
-
Contrast 3D Ultrasound
an ultrasound examination which will include a 3D reconstruction and thereafter CEUS will be performed using SONOVIEW contrast agent
Sponsors & Collaborators
-
Rambam Health Care Campus
lead OTHER
Principal Investigators
-
Erez Klein, MD · Rambam Health Care Campus
Study Design
- Allocation
- NA
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2020-09-30
- Primary Completion
- 2022-04-30
- Completion
- 2023-04-30
More Related Trials
-
Concordance of Three Imaging Methods by Dynamic CT, Contrast Ultrasound and CT Angiography in the Characterization of Endoleaks in Patients With an Aortic Endoprosthesis
NCT06318780 ·Status: RECRUITING ·Phase: NA
-
Contrast Enhanced Ultrasound vs. Computed Tomographic Angiography in the Detection of Endoleaks Following AAA Repair
NCT01230684 ·Status: TERMINATED ·Phase: NA
-
Dynamic Computed Tomography Angiography (CTA) Follow-up for EndoVascular Aortic Replacement (EVAR)
NCT00680004 ·Status: UNKNOWN
-
Tonometry and Duplex Ultrasound to Predict AAA Progression and CV Events in Aneurysm Patients (1-2-3 Trial)
NCT03989011 ·Status: COMPLETED
-
Enhanced Guidance for Endovascular Repair of Abdominal Aortic Aneurysm
NCT01824654 ·Status: COMPLETED ·Phase: NA
-
Follow-up After Endovascular Repair of Abdominal Aortic Aneurysm
NCT00488943 ·Status: UNKNOWN
-
AI-enhanced Imaging Analysis to Predict Post-EVAR
NCT06592105 ·Status: NOT_YET_RECRUITING
-
Mechanism and Prevention of Remote Organ Injury Following Ruptured Aortic Aneurysm
NCT00416000 ·Status: COMPLETED
-
Endovascular Aneurysm Repair (EVAR) Gate Study
NCT02934087 ·Status: COMPLETED ·Phase: NA
-
Prevention of Type II Endoleaks During Endovascular Treatment of Abdominal Aortic Aneurysm: Endovascular Treatment Versus Combination With Coil Embolisation of the Aneurysmal Sac
NCT01878240 ·Status: COMPLETED ·Phase: NA
-
3D Ultrasound of Abdominal Aortic Aneurysm Characteristics
NCT05871515 ·Status: ACTIVE_NOT_RECRUITING
-
Carbon Dioxide Guided Angiography in Endovascular Abdominal Aortic Aneurysm Repair
NCT04444999 ·Status: UNKNOWN ·Phase: NA
-
Overlay of 3D Scans on Live Fluoroscopy for Endovascular Procedures in the Hybrid OR
NCT01480206 ·Status: COMPLETED
-
Endovascular Aortic Repair of Free and Contained Ruptured Thoraco-Abdominal Aortic Aneurysm
NCT05956873 ·Status: COMPLETED
-
Tonometry(1) and Duplex Ultrasound(2) to Predict CV Events in to be Treated Patients With an AAA
NCT04183426 ·Status: RECRUITING
-
Ultrasound Velocimetry in the Abdominal Aorta Before and After Endovascular Aneurysm Repair
NCT05148988 ·Status: COMPLETED
-
Efficacy of Biomarkers and CEUS Versus CTA in AAA Follow-up Post-EVAR
NCT06866769 ·Status: RECRUITING
-
Using US to Evaluate Aortic Aneurysm Size Based on 3D Co-registration to Previous CT Scan
NCT02717481 ·Status: UNKNOWN
-
Pre-emptive Abdominal Aortic Aneurysm Sac Embolization During EVAR
NCT05575570 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Endovascular Exclusion of Thoracoabdominal and/or Paravisceral Abdominal Aortic Aneurysm
NCT00483249 ·Status: RECRUITING ·Phase: NA
-
EndoSure Sensor for Long-term Follow-up After Endovascular AAA Repair
NCT00831870 ·Status: UNKNOWN
-
Prospective, Non-Randomized Evaluation of Carbon Dioxide Gas as a Contrast Agent in Comparison With Iodinated Contrast in Endovascular Aneurysm Repair
NCT00520416 ·Status: COMPLETED
-
Evaluation of the Long Term Efficacy of Endovascular Treatment of Type 2 Endoleaks
NCT04409717 ·Status: COMPLETED
-
Non-invasive Aortic Aneurysm Tissue Characterization Using Wall Viscoelasticity
NCT04150653 ·Status: UNKNOWN
-
Evaluation of 3D Rotational Angiography After EVAR
NCT02894749 ·Status: COMPLETED ·Phase: NA