Tonometry(1) and Duplex Ultrasound(2) to Predict CV Events in to be Treated Patients With an AAA
NCT04183426 · Status: RECRUITING · Type: OBSERVATIONAL · Enrollment: 194
Last updated 2025-03-06
Summary
Abdominal aortic aneurysm (AAA) is a common vascular disease and associated with risk of rupture, but also with a high cardiovascular (CV) event rate. A key difficulty in AAA is predicting these life-threatening complications, which are strongly linked to vascular health. In 2013, the SMART risk score was developed to calculate the risk of the patients for recurrent vascular events based on clinical characteristics. Recently, a novel, easy to perform, non-invasive test of endothelial function (the carotid artery reactivity (CAR) test), reflecting target organ damage, has been introduced. The CAR is a simple, quick (5-min), non-invasive test that uses ultrasound to examine the carotid artery in response to sympathetic stimulation by placing one hand in cold water. This test shows strong agreement with both coronary and aortic responses to sympathetic stimulation and predicted CV-events in patients with peripheral arterial disease.
The aim of this prospective 2-year follow-up study is to investigate the predictive capacity of the CAR-test for development of CV-events after elective AAA repair in comparison to the SMART risk score. Secondary objectives are to investigate the predictive capacity of arterial stiffness measurements and the post-operative CAR-test for development of CV-events and to evaluate health status scores to provide insight if these scores can support clinical decision making.
Conditions
- Abdominal Aortic Aneurysm
- Cardiovascular Events
Interventions
- DIAGNOSTIC_TEST
-
Carotid Artery Reactivity test (CAR test)
The CAR test will be applied to stimulate the sympathetic nervous system. This thermal stimulus is known to elevate blood pressure via sympathetic pathways, so it can be used to study the vascular response to sympathetic activation. The participant will submerge their left hand in a bucket of ice water (approximately 4 degrees celcius) for 3 minutes, which is reported to be sufficient to induce a maximal dilation in the common carotid artery. At baseline and every minute after the hand is submerged in ice water, the blood pressure will be measured to check whether a sympathetic stimulation is achieved.
- DIAGNOSTIC_TEST
-
Arterial Stiffness
The SphygmoCor device will be used to non-invasively measure arterial stiffness parameters using applanation tonometry. For Pulse Wave Analyses (PWA), the radial waveform will be recorded. Approximately 10 waveforms are averaged, resulting in several non-invasive parameters: * Peripheral pressure parameters * Central and abdominal aneurysm pressure parameters (derived using a transfer function) * Cardiac output parameters (sub-endocardial viability ratio (SEVR), Ejection Duration (ED)) Pulse wave velocity will be performed by recording the waveforms of the carotid and femoral artery sequentially. The travelled distance will be measured according to the current guidelines and entered in the program. The program will calculate the PWV based on 10 ECG triggered waveform of each artery.
Sponsors & Collaborators
-
Radboud University Medical Center
collaborator OTHER -
Canisius-Wilhelmina Hospital
collaborator OTHER -
Gelderse Vallei Hospital
collaborator OTHER -
Medisch Spectrum Twente
collaborator OTHER -
Deventer Ziekenhuis
collaborator OTHER -
Gelre Hospitals
collaborator OTHER -
Maxima Medical Center
collaborator OTHER -
Rijnstate Hospital
lead OTHER
Principal Investigators
-
Michel Reijnen, MD, prof · Rijnstate Hospital
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2020-06-12
- Primary Completion
- 2026-12-31
- Completion
- 2027-06-30
Countries
- Netherlands
Study Locations
More Related Trials
-
Prediction of Abdominal Aortic Aneurysm Shrinkage After Stent-placement With Artificial Intelligence
NCT06250998 ·Status: RECRUITING
-
Screening Cardiovascular Patients for Aortic Aneurysms
NCT01643317 ·Status: COMPLETED
-
Non-invasive Aortic Aneurysm Tissue Characterization Using Wall Viscoelasticity
NCT04150653 ·Status: UNKNOWN
-
Investigation of the Neurovegetative Pattern in Patients With Thoracic Aortic Aneurysms (TAA)
NCT05703893 ·Status: ACTIVE_NOT_RECRUITING
-
Impact of Grafts and Endografts for Abdominal Aneurysms on Arterial Stiffness.
NCT02642952 ·Status: COMPLETED
-
Arterial Stiffness, Blood Pressure and Cardiac Output Study
NCT03469388 ·Status: COMPLETED ·Phase: NA
-
Clinical Study of the Treovance Stent-Graft for Patients With Abdominal Aortic Aneurysms
NCT02009644 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Vector Velocity Imaging in AAA Patients
NCT05841524 ·Status: ACTIVE_NOT_RECRUITING
-
Abdominal Compartment Syndrome and Ruptured Aortic Aneurysm : Validation of a Predictive Test
NCT02859662 ·Status: UNKNOWN
-
Ultrasound Velocimetry in the Abdominal Aorta Before and After Endovascular Aneurysm Repair
NCT05148988 ·Status: COMPLETED
-
The Pivotal Study of the Aptus Endovascular AAA Repair System
NCT00507559 ·Status: COMPLETED ·Phase: NA
-
Preoperative BNP and MINS in AAA Open Repair
NCT06088641 ·Status: ACTIVE_NOT_RECRUITING
-
Development of Ultra-Low Dose CT Based Screening for Aortic Aneurysms
NCT03479164 ·Status: COMPLETED ·Phase: NA
-
Standard Open Surgery Versus Endovascular Repair of Abdominal Aortic Aneurysm (AAA)
NCT00094575 ·Status: COMPLETED ·Phase: PHASE4
-
Predicting Rupture of AAA by Anatomic and Hemodynamic Markers
NCT02463760 ·Status: COMPLETED
-
A Prospective Analysis on the Expansion Rates of Abdominal Aortic Aneurysms
NCT02604303 ·Status: UNKNOWN
-
Evaluation of Predictors of Aortic Aneurysm Growth and Rupture
NCT02022436 ·Status: COMPLETED ·Phase: PHASE2
-
Fusion of CT Angiography With 3D Contrast Ultrasound as a Method for Follow up for Endovascular Aneurysm Repair
NCT04089241 ·Status: UNKNOWN ·Phase: NA
-
Comparison of Methods to Improve Abdominal Aortic Aneurysm (AAA) Screening Rates in the Primary Care Setting.
NCT01301534 ·Status: COMPLETED
-
Haemodynamic Response to Aortic Surgery
NCT01704391 ·Status: COMPLETED
-
Screening for Abdominal Aortic Aneurysm and Popliteal Artery Aneurysm
NCT05360108 ·Status: ACTIVE_NOT_RECRUITING
-
Detecting Abdominal Aortic Aneurysms in First Degree Relatives (Adult Offsprings) to AAA Patients (DAAAD)
NCT04623268 ·Status: COMPLETED
-
Non-invasive Monitoring of Endovascular Repair of Abdominal Aortic Aneurysm (VBA)
NCT03493074 ·Status: UNKNOWN
-
Screening of Abdominal Aortic Aneurysms Among Men With Coronary Artery Disease
NCT02086617 ·Status: COMPLETED ·Phase: NA
-
Contrast Enhanced Ultrasound Endoleak Identification and Classification
NCT04615559 ·Status: WITHDRAWN ·Phase: NA