Measuring Hydration Levels of Healthy and Heart Failure Patients Before, During, and After an Electrophysiology (EP) Procedure
NCT04609683 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 19
Last updated 2023-11-29
Summary
Subjects will be consented to wear the AleriTM sensor prior to, during, and after an Electrophysiology Procedure. During this time, the system will measure the following parameters from subjects: HR, temperature, saline volume/rate, urine production volume, USG, BPO. Data will be retrospectively analyzed to determine if the system effectively operates under these conditions, and can effectively monitor hydration levels of subjects compared to currently available methods.
Conditions
- Cardiac Arrhythmia
Interventions
- DEVICE
-
AleriTM sensors
AleriTM sensors are worn on the bicep or forearm and communicates through BLETM to a mobile App. The data is sent through the mobile App to web-based system processing where PHI is calculated and sent back to the mobile App. The AleriTM sensor has a form factor similar to a conventional arm band, with a hockey puck shape of approximately 48mm in diameter and 15mm in thickness the AleriTM sensor is a non-significant risk (NSR) device as it does not meet the definition of significant risk device (21 CFR 812.3(m)) because it is: not an implant; is not purported or represented to support or sustain human life; its use is not of substantial importance in the diagnosis, cure, treatment, mitigation, or prevention of impairment of health; and it does not present a serious risk to the health, safety, or welfare of a subject.
Sponsors & Collaborators
- lead OTHER
Principal Investigators
-
Lior Jankelson · NYU Langone Health
Study Design
- Allocation
- NA
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Max Age
- 100 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2022-09-19
- Primary Completion
- 2022-11-21
- Completion
- 2023-11-05
Countries
- United States
Study Locations
More Related Trials
-
Introductory Clinical Trial for Measuring Patients Before, During, and After an Electrophysiology (EP) Procedure With a Novel, Body-Worn Sensor
NCT03657134 ·Status: COMPLETED ·Phase: NA
-
Preliminary Research Evaluation for Ambulatory Leadless Electrocardiogram Recorder Trial
NCT05357716 ·Status: COMPLETED
-
Biventricular Versus Right Ventricular Pacing in Heart Failure Patients With Atrioventricular Block (BLOCK HF)
NCT00267098 ·Status: COMPLETED ·Phase: NA
-
ECG App Algorithms Clinical Validation Study
NCT04247581 ·Status: COMPLETED ·Phase: NA
-
Evaluation of a Test Algorithm for Use to Analyze ECG Data Collected From a Test Device of a 24-hour Simulated Use Period
NCT07188129 ·Status: COMPLETED ·Phase: NA
-
Respiratory Sinus Arrhythmia (RSA) Pacing Post-CABG Surgery in Patients With HFrEF
NCT06359938 ·Status: RECRUITING ·Phase: NA
-
Respiratory Sinus Arrhythmia Pacing Post-CABG Surgery in Patients With HFrEF
NCT06384963 ·Status: RECRUITING ·Phase: NA
-
Remote ECG Monitoring of TAVI Patients
NCT03810820 ·Status: UNKNOWN ·Phase: NA
-
Validation of an iPhone-based Event Recorder for Arrhythmia Detection
NCT02005172 ·Status: COMPLETED ·Phase: NA
-
A Study to Assess Multidomain Endpoints of an ECG Patch
NCT06243029 ·Status: COMPLETED
-
Cardiac Resynchronization Therapy (CRT) Based Heart Failure Monitoring Study
NCT00632372 ·Status: COMPLETED
-
Sensing Ventricular Arrhythmias by His Bundle Leads
NCT03530423 ·Status: WITHDRAWN
-
Diagnostic Device Risk Management of Atrial Fibrillation and Heart Failure
NCT01486316 ·Status: COMPLETED ·Phase: NA
-
Diagnostic Accuracy of WEARable TECHnology Single-lead ECG in Detecting Cardiac Arrhythmias
NCT05298553 ·Status: COMPLETED ·Phase: NA
-
Mobile Cardiac Telemetry and Advanced Multi-Parameter Monitoring in Patients
NCT04754204 ·Status: COMPLETED
-
Prospective Study to Validate the Clinical Accuracy of the Norbert Device to Measure Pulse Rate
NCT05640323 ·Status: COMPLETED
-
A Study to Determine the Feasibility of Wireless Electrocardiography
NCT02162394 ·Status: COMPLETED
-
Relation of Non-invasively Measured Parameters to Clinical Outcomes in CHF Patients
NCT04548024 ·Status: COMPLETED
-
Benefits of µCor in Ambulatory Decompensated Heart Failure
NCT03476187 ·Status: COMPLETED ·Phase: NA
-
Future Cardia™ Insertable Cardiac Monitor in Subjects With Paroxysmal Atrial Fibrillation (First-in-Human Study)
NCT06167434 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Heart Failure Study of Multi-site Pacing Effects on Ventriculoarterial Coupling
NCT03189368 ·Status: COMPLETED
-
Correlating QLV Interval to Left Ventricular (LV) Lead Position in Patients Receiving Cardiac Resynchronization Therapy.
NCT02166762 ·Status: COMPLETED ·Phase: NA
-
Selective Coronary Vein Sampling in Left Bundle Branch Block and CRT
NCT02396875 ·Status: UNKNOWN ·Phase: NA
-
Precision Event Monitoring for Patients With Heart Failure Using HeartLogic
NCT03579641 ·Status: COMPLETED
-
BIO|CONCEPT.BIOMONITOR-HF Collect Clinical Data From Heart Failure Patients Using BIOMONITOR Devices With a Study Specific Research Software
NCT06989580 ·Status: RECRUITING ·Phase: NA