Diagnostic Device Risk Management of Atrial Fibrillation and Heart Failure
NCT01486316 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 24
Last updated 2018-07-12
Summary
The purpose of this study is to characterize the feasibility and impact of a diagnostic tool that may help clinicians identify when patients are at higher risk of visiting the hospital for a heart failure event. The study will use a non-experimental device that is inserted just under the skin of the chest, which continuously monitors the heart rhythm in combination with an experimental web-based heart failure risk status. Patients with atrial fibrillation and heart failure will be evaluated to collect data about the potential of this risk status to help improve patient outcome.
Conditions
Interventions
- DEVICE
-
Reveal XT® Insertable Cardiac Monitor
If not previously implanted, a non-experimental insertable cardiac monitor will be implanted to collect information on the patients' heart condition as inputs into the heart failure risk status algorithm (during guided follow-up only, Guided arm: 6-18 months, Control arm: 12-18 months).
- OTHER
-
Heart Failure Risk Status Diagnostic
The experimental IDENTIFY-HF Risk Status developed for this study will be used to change standard device data to a heart failure risk status. The risk status and standard device trend data are provided to study doctors for remote management of their patients' heart failure using study specific protocols. The risk status inputs are: night heart rate, heart rate variability, atrial fibrillation burden, ventricular rate during atrial fibrillation, patient activity. Based on pre-defined thresholds for each of the above inputs, as well as data trends, a heart failure score is derived. The heart failure score is then classified as: "Low", "Medium", "High", or "Very High".
Sponsors & Collaborators
-
Medtronic Cardiac Rhythm and Heart Failure
lead INDUSTRY
Principal Investigators
-
IDENTIFY-HF Team · Medtronic
Study Design
- Allocation
- RANDOMIZED
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2011-11-30
- Primary Completion
- 2014-12-31
- Completion
- 2015-02-28
Countries
- United States
Study Locations
More Related Trials
-
A Novel Healthcare Information Technology Tool to Improve Care in Patients With Atrial Fibrillation
NCT02623517 ·Status: COMPLETED
-
Safety and Efficacy of Automatic Testing Feature in New ICDs and CRT-Ds
NCT00746356 ·Status: COMPLETED ·Phase: NA
-
Evaluation of a Diagnostic Feature in a Cardiac Resynchronization Therapy (CRT) Device
NCT00957541 ·Status: COMPLETED ·Phase: PHASE2
-
Heart Failure and Risk of Re-Admissions Determined by Abnormal REVEAL Parameters
NCT01357408 ·Status: TERMINATED
-
Evaluation of Left Ventricular AutoThreshold
NCT00812201 ·Status: COMPLETED
-
Novel Vascular Biomarkers Behaviour and Clinical Value in Heart Failure and CRT
NCT02541773 ·Status: UNKNOWN
-
Precision Event Monitoring for Patients With Heart Failure Using HeartLogic
NCT03579641 ·Status: COMPLETED
-
Reveal LINQ™ Heart Failure
NCT02758301 ·Status: COMPLETED
-
PARTNERS HF: Program to Access and Review Trending Information and Evaluate Correlation to Symptoms in Patients With Heart Failure
NCT00279955 ·Status: COMPLETED
-
Personalized Risk Identification and Management for Arrhythmias and Heart Failure by ECG and MRI
NCT01353131 ·Status: COMPLETED
-
Reveal® XT Performance Trial (XPECT)
NCT00680927 ·Status: COMPLETED ·Phase: PHASE4
-
Safety and Performance Aspects of CRT-DX System in Patients With Sinus Rhythm
NCT03839121 ·Status: COMPLETED
-
Implantable Cardiac Monitors in High-Risk Post-Infarction Patients With Cardiac Autonomic Dysfunction
NCT02594488 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Left Ventricular Autothreshold, Phase Two
NCT01242722 ·Status: COMPLETED
-
TRENDS: A Prospective Study of the Clinical Significance of Atrial Arrhythmias Detected by Implanted Device Diagnostics
NCT00279981 ·Status: COMPLETED
-
Clinical Investigation of the Medtronic EnTrust™ Implantable Cardioverter Defibrillator (ICD), Model D153ATG
NCT00273195 ·Status: COMPLETED ·Phase: NA
-
The Epidemiology of Ventricular Assist Device-Related Infections
NCT01471795 ·Status: COMPLETED
-
Cardiac Resynchronization Therapy (CRT) Based Heart Failure Monitoring Study
NCT00632372 ·Status: COMPLETED
-
Comparison of CRT-D and CRT-DX Systems (CRT-NEXT)
NCT03587064 ·Status: RECRUITING ·Phase: NA
-
Non-Invasive Method for Evaluation of Cardiac Resynchronization Therapy
NCT05868616 ·Status: RECRUITING
-
Low Level Tragus Stimulation in Acute Decompensated Heart Failure
NCT02898181 ·Status: RECRUITING ·Phase: NA
-
Clinical Evaluation Of Remote Monitoring With Direct Alerts To Reduce Time From Event To Clinical Decision
NCT01090349 ·Status: COMPLETED ·Phase: NA
-
DISCOVERY: Diagnostic Data and Genetic Polymorphisms in ICD Patients.
NCT00478933 ·Status: COMPLETED ·Phase: NA
-
Efficacy of Implantable Defibrillator Therapy After a Myocardial Infarction
NCT00673842 ·Status: COMPLETED ·Phase: PHASE3
-
Integrated Diagnostics Driven Diuretic and Chronic Medication Management for Heart Failure
NCT02698241 ·Status: TERMINATED ·Phase: NA