Respiratory Sinus Arrhythmia (RSA) Pacing Post-CABG Surgery in Patients With HFrEF
NCT06359938 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 54
Last updated 2024-12-13
Summary
The goal of this clinical trial is to test a new type of pacemaker in heart failure patients following a heart bypass operation. The new pacemaker restores respiratory sinus arrhythmia which is a natural pattern where the heart rate increases when the participants breathe in and slows down when participants breathe out.
The main questions the trial aims to answer are:
* Is the new type of pacemaker safe?
* Does the new type of pacemaker improve how patients' hearts work (also known as cardiac output)?
Participants will have a range of tests before their operation and during their recovery in hospital while participants have the new type of pacemaker in place, and will be monitored very closely. Participants will also receive a phone call 1 month after their surgery. Researchers will compare the new type of heart pacing against standard treatment to see if it is as safe, and if it is any better for patients.
Conditions
- Heart Failure With Reduced Ejection Fraction
Interventions
- DEVICE
-
Atrial pacing with respiratory sinus arrhythmia (RSA) variability
The intervention in this study is a modification of the pacing output from a standard external pacemaker such that it will approximate the RSA variation found in healthy subjects. A pacemaker (PACE204, Osypka Medical AG), similar to those currently in common use in post-CABG patients, will be adapted to receive an additional input signal based on the respiratory signal (Ceryx device). The respiration signal will be combined with the ECG signal to determine the appropriate pacing interval. The pacing impulse will be delivered by the pacemaker unit.
- DEVICE
-
Monotonic right atrial overdrive pacing
Pacing is delivered by a PACE204 pacemaker (Osypka Medical AG) delivering standard monotonic right atrial pacing
Sponsors & Collaborators
-
Cardiff and Vale University Health Board
collaborator OTHER_GOV -
Ceryx Medical Ltd
lead INDUSTRY
Principal Investigators
-
Zaheer Yousef · Cardiff and Vale University Health Board
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 22 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2024-11-22
- Primary Completion
- 2026-03-01
- Completion
- 2026-04-01
Countries
- United Kingdom
Study Locations
More Related Trials
-
Application of Right Atrial Left Ventricular Fusion Pacing in Patients With CRT Indications
NCT03071978 ·Status: COMPLETED ·Phase: NA
-
Biventricular Versus Right Ventricular Pacing in Heart Failure Patients With Atrioventricular Block (BLOCK HF)
NCT00267098 ·Status: COMPLETED ·Phase: NA
-
Safety and Effectiveness of Left Bundle Branch Area Pacing Versus Conventional Cardiac Resynchronization Therapy in Heart Failure
NCT07069738 ·Status: RECRUITING ·Phase: NA
-
RethinQ Study - Evaluating Pacing in Heart Failure Patients
NCT00132977 ·Status: COMPLETED ·Phase: PHASE3
-
Pacing for Heart Failure With Preserved Ejection Fraction
NCT01045291 ·Status: COMPLETED ·Phase: NA
-
Effect of Right Bifocal Ventricular Cardiac Pacing on Serum Level Natriuretic Peptides in Patients With Heart Failure
NCT02186314 ·Status: UNKNOWN ·Phase: NA
-
PROSPECT: Predictors of Response to Cardiac Re-Synchronization Therapy
NCT00253357 ·Status: COMPLETED
-
Pacing in Heart Failure With Preserved LVEF
NCT03215849 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Monitoring of Arrhythmias and HRV in Patients With Heart Failure Treated With the CRT Pacemaker Renewal TR2
NCT00180531 ·Status: COMPLETED ·Phase: PHASE4
-
Predicting Response to Cardiac Resynchronization Therapy in Heart Failure
NCT00359372 ·Status: COMPLETED
-
Predictors of Response to Biventricular Pacing in Heart Failure
NCT00156390 ·Status: COMPLETED ·Phase: NA
-
Optimal Pacing Rate for Cardiac Resynchronization Therapy
NCT06445439 ·Status: RECRUITING ·Phase: NA
-
Cardiac Resynchronisation Study
NCT01213537 ·Status: COMPLETED
-
Ventricular Rate Regularization for Improved Quality of Life in Patients With CHF and AF
NCT00583921 ·Status: WITHDRAWN
-
Comparison of Medical Therapy, Pacing and Defibrillation in Heart Failure
NCT00180258 ·Status: COMPLETED ·Phase: PHASE2/PHASE3
-
Heart Failure Study of Multi-site Pacing Effects on Ventriculoarterial Coupling
NCT03189368 ·Status: COMPLETED
-
Tailoring Pacemaker Output to Physiology in Chronic Heart Failure
NCT03781427 ·Status: UNKNOWN ·Phase: PHASE3
-
Response of Cardiac Resynchronization Therapy Optimization With Ventricle to Ventricle Timing in Heart Failure Patients
NCT00187200 ·Status: COMPLETED ·Phase: PHASE4
-
Effects of Left Ventricular Pacing Optimilization on Cardiac Perfusion, Contractile Force, and Clinical Performance in Patients With Ventricular Dysfunction and Heart Failure
NCT00551681 ·Status: COMPLETED ·Phase: NA
-
ENHANCE-Efficacy of the Presence of Right Ventricular Apical Pacing Induced Ventricular Dyssynchrony as a Guiding Parameter for Biventricular Pacing in Patients With Bradycardia and Normal Ejection Fraction
NCT01559311 ·Status: COMPLETED ·Phase: NA
-
Cardiac Resynchronization Therapy, Dyspnea and Exercise Tolerance in Patients With Congestive Heart Failure (CHF)
NCT00700700 ·Status: TERMINATED ·Phase: PHASE4
-
Effect of Targeting Left Ventricular Lead Position on the Rate of Response to Cardiac Resynchronization Therapy.
NCT00399594 ·Status: COMPLETED ·Phase: PHASE2/PHASE3
-
Physiologic Accelerated Pacing as a Treatment in Patients With Heart Failure With Preserved Ejection Fraction
NCT04546555 ·Status: COMPLETED ·Phase: NA
-
LVSP Based CRT vs. RVAP Based CRT
NCT05985408 ·Status: UNKNOWN ·Phase: NA
-
Response to Cardiac Resynchronization Therapy of Previously Right Ventricular Paced Heart Failure Patients
NCT01466621 ·Status: COMPLETED