Combination of Medium Cut-off Dialyzer Membrane and Diet Modification to Alleviate Residual Uremic Syndrome of Dialysis Patients
NCT04247867 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 50
Last updated 2022-05-18
Summary
The study will compare achieved levels of protein-bound uremic toxins with dialysis using a medium cut-off membrane compared to the treatment by online haemodiafiltration with a high-flux dialysis membrane. In the second phase of the study dietary fiber and short-chain fatty acid intake will be increased to verify a possible additional reduction in the levels of protein bound uremic toxins.
Conditions
- End Stage Renal Disease
- Haemodialysis
- Diet, Healthy
Interventions
- DEVICE
-
medium cut-off (MCO) dialysis membrane
Medium cut-off dialysis (MCO) membrane is a dialysis membrane with a higher molecular weight retention onset and similar cut-off as standard high-flux dialysis membranes. It is capable of providing increased clearance of medium sized uremic toxins and some plasma proteins (cytokines, inflammatory mediators).
- DIETARY_SUPPLEMENT
-
Dietary fiber mixture (Plantago Psyllium and Inulin)
Dietary fiber (Psyllium 69% and Inulin 30% mixture) added to the meals in the dose of 5g BID for 4 weeks in the second phase of the study.
- DIETARY_SUPPLEMENT
-
Sodium propionate
Sodium propionate (a short-chain fatty acid) added to the meals in the dose of 500 mg BID in the second phase in the study.
Sponsors & Collaborators
-
University of Ljubljana
collaborator OTHER -
University Medical Centre Ljubljana
lead OTHER
Principal Investigators
-
Jernej Pajek, MD, PhD · Nephrology department, University Medical Centre Ljubljana, Slovenia
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2020-08-31
- Primary Completion
- 2022-08-30
- Completion
- 2022-10-31
Countries
- Slovenia
Study Locations
More Related Trials
-
Reduction Ratio and Clearance During Hemodialysis With MCO-filter Compared to HDF With Standard High-flux Filter
NCT03437538 ·Status: COMPLETED ·Phase: NA
-
Interdialytic Peritoneal UltraFiltration in HemoDialysis Patients
NCT04603014 ·Status: ACTIVE_NOT_RECRUITING ·Phase: PHASE2
-
12 Weeks of Hemodialysis With Medium Cut-Off Filter Compared to Hemodiafiltration With Standard High-flux Filter.
NCT03416192 ·Status: WITHDRAWN ·Phase: NA
-
Efficacy of Twice Weekly Hemodialysis in Patients With Residual Kidney Function
NCT03874117 ·Status: COMPLETED ·Phase: NA
-
Clinical and Biochemical Effects of Multipass Hemodialysis
NCT01267760 ·Status: COMPLETED ·Phase: PHASE2
-
Modulation of Inflammation by Medium Cut Off Membranes
NCT03270371 ·Status: UNKNOWN ·Phase: NA
-
A Comparison of Protein-bound and Large Molecular Weight Uremic Toxin Removals With Novel Super High-flux Dialyzer Between Hemodialysis and High Volume Online HDF Modalities
NCT06567483 ·Status: COMPLETED ·Phase: NA
-
Toxins Removal and Inflammatory State modulAtion During Online Hemodiafiltration: Comparison of Two Different Dialyzers
NCT04554498 ·Status: UNKNOWN ·Phase: NA
-
A Study to Evaluate the Efficacy and Safety of an Experimental Solution for Peritoneal Dialysis
NCT00214721 ·Status: COMPLETED ·Phase: PHASE3
-
Comparison FX CorDiax 60 in Relation to the FX 60-Dialyzer
NCT01534741 ·Status: COMPLETED ·Phase: PHASE4
-
Comparison of the Removal of Uremic Toxins With Medium Cut-off and Super High-flux Vitamin E-coated Dialyzers
NCT05610683 ·Status: COMPLETED ·Phase: NA
-
Dialysis Performance of the FX CorAL Membrane
NCT06203795 ·Status: COMPLETED ·Phase: NA
-
Effect of Dialysis Dose and Membrane Flux in Maintenance Hemodialysis
NCT00004285 ·Status: COMPLETED ·Phase: NA
-
Expanded Hemodialysis Versus Online Hemodiafiltration
NCT03274518 ·Status: COMPLETED ·Phase: NA
-
The Microcirculation, Dialysis Modality and Sequestered Salt
NCT06327750 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Safety and Efficacy Assessments of NeoKidney® in ESRD Patients Treated With Short Daily Hemodialysis
NCT06024135 ·Status: UNKNOWN ·Phase: NA
-
Effect of Kidney Replacement Therapy with Polymethylmethacrylate Membranes on Pruritus-related Quality of Life in Patients Receiving Maintenance Haemodialysis
NCT06671535 ·Status: RECRUITING ·Phase: NA
-
The Effect of Vitamin E-coated Polysulfone Membrane on Oxidative Stress, Inflammation and Monocytes in Critically Ill Patients in CRRT
NCT03489759 ·Status: UNKNOWN ·Phase: NA
-
Clinical Study on Optimised Removal of Protein-bound Uremic Toxins With Convective Dialysis Treatment.
NCT00337831 ·Status: COMPLETED ·Phase: NA
-
Investigation on the Middle Size Molecule Elimination Characteristics of the FXCorDiax 100 in Relation to the FX 100 and the Polyflux 210 H Dialyser
NCT01578421 ·Status: COMPLETED ·Phase: NA
-
Efficacy and Safety of Repeated-use Middle Cut Off Membrane Dialyzers in Hemodialysis Patients
NCT06950944 ·Status: COMPLETED ·Phase: NA
-
Dialysis Performance of Different Dialyzer Membranes Using Different Coagulation Strategies
NCT03820401 ·Status: COMPLETED ·Phase: NA
-
Randomised Evaluation of Sodium Dialysate Levels on Vascular Events
NCT02823821 ·Status: RECRUITING ·Phase: PHASE4
-
Comparison of Hemodialysis With Medium Cut-off Dialyzer (Theranova) and High Flux Dialyzer
NCT03211676 ·Status: COMPLETED ·Phase: NA
-
MCO Membrane Efficiency in Septic Shock Patients
NCT04834921 ·Status: COMPLETED ·Phase: NA