Comparison of the Removal of Uremic Toxins With Medium Cut-off and Super High-flux Vitamin E-coated Dialyzers
NCT05610683 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 41
Last updated 2024-04-04
Summary
End-stage renal disease (ESRD) induces an accumulation of uremic toxins responsible for increased morbidity and mortality. These toxins cover a wide range of molecules, classified according to their molecular weight as small-size (\< 500 Da), middle-size (500 Da-60 kDa), and protein-bound toxins.
Specific complications have been associated with the accumulation of middle-size toxins, including beta2-microglobulin (12 kDa), myoglobin (17 kDa), prolactin (23 kDa), alpha1-microglobulin (33 kDa), alpha1-glycoprotein (44 kDa), kappa (22 kDa) and lambda (45 kDa) free light chains (FLC). Moreover, mediators of oxidative stress such as asymmetric dimethylarginine, malondialdehyde, oxidative-LDL and inflammatory cytokines such as Interleukin-6 (IL)-6, IL1-β, TNF-α have been involved in atherosclerosis, malnutrition, cardiovascular events and mortality.
Hemodialysis (HD) remains the main standard modality of renal replacement therapy in ESRD. In the past decade, low-flux hemodialysis was most commonly used, providing effective clearance of small solutes through diffusion, but negligible clearance of middle molecules. This limitation was insufficiently improved by the development of high-flux (HF) dialyzers due to their cut-off pores size values of approximately 15-20 kDa. In fact, most of middle molecules cannot be efficiently removed by HF-HD because of their molecular radii larger than that of membrane pores. Thus, HF dialyzers were used in post dilution on-line hemodiafiltration (OL-HDF) mode with high convection volumes and achieved greatest clearance of middle molecules. However, OL-HDF is generally not available in most HD centers and needs additional hardware technology. Therefore, several super high-flux (SHF) dialyzers integrating higher cut-off size pore value and achieving Beta2-microglobulin clearance \> 70 ml/min were developed for HD mode. These SHF dialyzers used in HD (SHF-HD) provides similar middle molecules depuration compared to OL-HDF.
The recently developed medium cut-off (MCO) dialyzer (Theranova 500™, Baxter healthcare Corporation Deerfield, USA; surface area 2 m², ultrafiltration coefficient: 59 ml/h/mmHg) differs from conventional HF membranes by higher and controlled porosity resulting in a steep sieving curve with a cut-off value approaching that of albumin. MCO-HD has demonstrated efficient depuration of middle uremic toxins as compared to HF-HD, similar to that of OL-HDF. MCO-HD and SHF-HD are two new large pore size dialyzers currently used nowadays in HD.
In addition, the interaction between blood and membrane surface play a key role in generating oxidative stress and inflammation. Antioxidants such as vitamin E work by inhibiting LDL oxidation and by limiting cellular response to oxidized LDL. In HD patients, vitamin E may be integrated as a part of the HD procedure in the form of bioreactive dialysis membranes, in which the blood surface has been modified with alpha-tocopherol. Dialysis with vitamin E-coated membranes has been associated with an improvement in biocompatibility including circulating lipid peroxidation biomarkers and cytokine induction. In small studies, vitamin E coated dialyzers have been associated with reduced red blood count fragility and improvements in erythropoietin resistance index and erythropoietin requirements in HD.
VieX (Polysulfone, surface area: 2.1 m², sterilization gamma, ultrafiltration coefficient: 104.3 ml/h/mmHg, Asahi Kasei Medical, Japan), a novel SHF vitamin E-coated (SHVE) dialyzer, which has larger pore size than HF dialyzer, might provide higher middle molecules removal and biocompatibility improvement.
The aim of the present study was to compare the efficiency of the SHFVE dialyzer (VieX™) versus the MCO dialyzer (Theranova 500™) on the removal of beta2-microglobulin and other middle molecules in a non-inferiority fashion, and their respective effects on inflammation, oxidative stress and biocompatibility parameters.
Conditions
- End Stage Renal Disease (ESRD)
Interventions
- DEVICE
-
Hemodialysis sessions using SHFVE dialyzer (VieX™) or the MCO (Theranova 500™) dialyzer
Patients will receive thrice weekly 4 hours hemodialysis sessions during 3 months
Sponsors & Collaborators
-
Hemotech
collaborator INDUSTRY -
Poitiers University Hospital
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- OTHER
- Masking
- NONE
- Model
- CROSSOVER
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2023-06-14
- Primary Completion
- 2024-01-31
- Completion
- 2024-01-31
Countries
- France
Study Locations
More Related Trials
-
The Effect of Vitamin E-coated Polysulfone Membrane on Oxidative Stress, Inflammation and Monocytes in Critically Ill Patients in CRRT
NCT03489759 ·Status: UNKNOWN ·Phase: NA
-
Super High-Flux - High Volume Dialysis in Sepsis-Induced Acute Renal Failure
NCT00333593 ·Status: COMPLETED ·Phase: PHASE1/PHASE2
-
Development of an Innovative Hemodialysis Method to Improve Dialytic Clearance of Protein-bound Uremic Toxins
NCT06595680 ·Status: NOT_YET_RECRUITING ·Phase: PHASE2
-
Effects of pHA Hemoperfusion Plus Hemodialysis on Protein-Bound Uremic Toxins
NCT07016841 ·Status: RECRUITING
-
Combination of Medium Cut-off Dialyzer Membrane and Diet Modification to Alleviate Residual Uremic Syndrome of Dialysis Patients
NCT04247867 ·Status: UNKNOWN ·Phase: NA
-
Study in End Stage Renal Disease (ESRD) Patients on Hemodialysis to Determine Non-inferiority of the Theranova Dialyzer Compared to the FX80 Dialyzer
NCT03547323 ·Status: COMPLETED ·Phase: NA
-
Effect of Dialysis Dose and Membrane Flux in Maintenance Hemodialysis
NCT00004285 ·Status: COMPLETED ·Phase: NA
-
Exploratory Study to Explore the Safety and Efficacy of the HDx Therapy Using Theranova 500 Dialyzer in Comparison to Hemodiafiltration
NCT03499691 ·Status: COMPLETED ·Phase: NA
-
Impact of Bevel Orientation on Arteriovenous Fistula Puncture in Hemodialysis
NCT06708338 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Investigation on the Middle Size Molecule Elimination Characteristics of the FXCorDiax 100 in Relation to the FX 100 and the Polyflux 210 H Dialyser
NCT01578421 ·Status: COMPLETED ·Phase: NA
-
Clinical Study to Assess the Performance of the Dialyzer With Endexo™
NCT03536663 ·Status: COMPLETED ·Phase: NA
-
Effect of Hemodiafiltration Plus MCOs on Uremic Toxins Removal
NCT03938285 ·Status: UNKNOWN ·Phase: NA
-
Comparison of Hemodialysis With Medium Cut-off Dialyzer (Theranova) and High Flux Dialyzer
NCT03211676 ·Status: COMPLETED ·Phase: NA
-
Moda-flx Hemodialysis System™ Under Professional Care Settings by Trained Individuals and At Home by Participants
NCT06613568 ·Status: RECRUITING ·Phase: NA
-
Efficacy of Uremic Toxins Clearance With Expanded Hemodialysis
NCT04786535 ·Status: UNKNOWN ·Phase: NA
-
Evaluation of Daily Hemodialysis With Low Dialysate Flux in Unscheduled Patients With Kidney Injury Admitted to Hemodialysis
NCT03963960 ·Status: TERMINATED ·Phase: NA
-
Comparative Effects Of Dialysate Flow Rate And Membrane Packing On The Performance Of Dialyzers Used For Hemodialysis
NCT00636077 ·Status: COMPLETED ·Phase: NA
-
Comparison of the Clinical Performance of 3 THERANOVA 400 Dialyzer Prototypes With a High-Flux Dialyzer in Hemodialysis Mode
NCT02377570 ·Status: COMPLETED ·Phase: NA
-
Theranova Randomized, Controlled, Trial (RCT) in China
NCT05309291 ·Status: COMPLETED ·Phase: NA
-
Reduction of Heparin Dose in Dialysis With Evodial System
NCT00781690 ·Status: COMPLETED ·Phase: NA
-
Comparing Super High-flux and High-flux Dialyzer Performance Among Hemodialysis Patient With Sepsis : a Randomized Control Trial
NCT06989892 ·Status: RECRUITING ·Phase: NA
-
Clearum High Flux Hemodialyzer Used in Hemodialysis for Subjects With End-Stage Renal Disease
NCT04395131 ·Status: COMPLETED ·Phase: NA
-
Immunomodulatory Biomimetic Device to Treat Myocardial Stunning in End-stage Renal Disease Patients
NCT03539861 ·Status: TERMINATED ·Phase: NA
-
Hemodiafiltration With Endogenous Reinfusion on Uremic Toxins Clearance of Maintenance Hemodialysis Patients
NCT06002529 ·Status: UNKNOWN ·Phase: NA
-
Removal of Ligand-bound Iron During Intravenous (IV) Iron Administration in Hemodialysis (HD)
NCT00638300 ·Status: COMPLETED ·Phase: NA