Clinical and Biochemical Effects of Multipass Hemodialysis
NCT01267760 · Status: COMPLETED · Phase: PHASE2 · Type: INTERVENTIONAL · Enrollment: 12
Last updated 2013-07-09
Summary
The purpose of this study is to investigate whether recycled dialysis fluid can supply enough clearance for hemodiaysis patients.
Conditions
- Uremia
Interventions
- DEVICE
-
Multipass hemodialysis
8-hour dialysis using a recycled dialysis bath of 25-30 l
Sponsors & Collaborators
-
Flexdialysis ApS
collaborator UNKNOWN -
Herlev Hospital
lead OTHER
Principal Investigators
-
James G Heaf, MD DMSc · Herlev Hospital
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Max Age
- 90 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2011-03-31
- Primary Completion
- 2011-06-30
- Completion
- 2011-06-30
Countries
- Denmark
Study Locations
More Related Trials
-
Uremic Toxin Removal and Hemodynamics in Long-hour Hemodialysis and Hemodiafiltration
NCT01328119 ·Status: COMPLETED ·Phase: NA
-
Development of an Innovative Hemodialysis Method to Improve Dialytic Clearance of Protein-bound Uremic Toxins
NCT06595680 ·Status: NOT_YET_RECRUITING ·Phase: PHASE2
-
Dialysis Performance of the FX CorAL Membrane
NCT06203795 ·Status: COMPLETED ·Phase: NA
-
Tolerance of "on Line" Hemodiafiltration in Chronic Renal Failure Patients
NCT01327391 ·Status: COMPLETED ·Phase: PHASE4
-
Efficacy of Twice Weekly Hemodialysis in Patients With Residual Kidney Function
NCT03874117 ·Status: COMPLETED ·Phase: NA
-
Efficacy of Uremic Toxins Clearance With Expanded Hemodialysis
NCT04786535 ·Status: UNKNOWN ·Phase: NA
-
Integrated Patient Care Intradialysis Programme in Hemodialysis Through a Virtual Health Platform
NCT04823286 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Hemodiafiltration With Endogenous Reinfusion on Uremic Toxins Clearance of Maintenance Hemodialysis Patients
NCT06002529 ·Status: UNKNOWN ·Phase: NA
-
Clinical Study on Optimised Removal of Protein-bound Uremic Toxins With Convective Dialysis Treatment.
NCT00337831 ·Status: COMPLETED ·Phase: NA
-
Study of a Dialysate Without Acetate on Protein Energy Wasting Syndrome in Chronic Hemodialysis Patient (EASY)
NCT04824885 ·Status: COMPLETED ·Phase: NA
-
The Use of Low Molecular Weight Heparin in Hemodiafiltration
NCT00756145 ·Status: COMPLETED ·Phase: PHASE4
-
The Benefit of Оn-Line High Convection Volume Hemodiafiltration Treatment Versus High Flow Dialysis on Reduction of Oxidative Stress and Health Related Quality of Life in Dialysis Patients
NCT02673099 ·Status: COMPLETED ·Phase: NA
-
Expanded Hemodialysis Versus High-Volume Online Hemodiafiltration for Uremic Toxin Removal
NCT07348536 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Protein-Bound Uremic Retention Solutes in Long Nocturnal Hemodialysis
NCT00417105 ·Status: COMPLETED
-
Solute Removal With High Volume Hemodiafiltration Versus Long High Flux Hemodialysis
NCT01445366 ·Status: COMPLETED ·Phase: NA
-
Reduction Ratio and Clearance During Hemodialysis With MCO-filter Compared to HDF With Standard High-flux Filter
NCT03437538 ·Status: COMPLETED ·Phase: NA
-
Comparison of Dialysis Strategies in Critically Ill Patients With Acute Renal Failure
NCT00322530 ·Status: COMPLETED ·Phase: NA
-
The Microcirculation, Dialysis Modality and Sequestered Salt
NCT06327750 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Hemodialysis Blood Flow and Urea Clearance
NCT02484118 ·Status: COMPLETED ·Phase: NA
-
Functionality of Albumin in the Context of Hemodialysis
NCT06561191 ·Status: RECRUITING ·Phase: NA
-
The Danish Symptomburden Study Among Patients With Advanced Kidney Disease
NCT06019871 ·Status: UNKNOWN
-
Combination of Medium Cut-off Dialyzer Membrane and Diet Modification to Alleviate Residual Uremic Syndrome of Dialysis Patients
NCT04247867 ·Status: UNKNOWN ·Phase: NA
-
Coupling Between Clotting Characteristics in Chronic Hemodialysis Patients and the Hemodialyzer Patency
NCT05440201 ·Status: COMPLETED ·Phase: NA
-
Strategies for Asymmetrical Triacetate Dialyzer Heparin-Free Effective Hemodialysis
NCT04381234 ·Status: COMPLETED ·Phase: PHASE2
-
Investigation on the Middle Size Molecule Elimination Characteristics of the FXCorDiax 100 in Relation to the FX 100 and the Polyflux 210 H Dialyser
NCT01578421 ·Status: COMPLETED ·Phase: NA