Comparison of Endotracheal Intubation Over the Aintree With Fiberoptic Bronchoskop Via the I-gel and LMA Protector
NCT03501602 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 80
Last updated 2018-04-19
Summary
Investigators aimed to compare the ease of use of the LMA protector and I-gel LMA for tracheal intubation with the Aintree catheter in our study.
Laryngeal mask airway (LMA) protector is the second generation perilaryngeal seal type supraglottic airway tool. The I-gel LMA is the second generation uncuffed supraglottic airway device. The Aintree Intubation Catheter has been designed for assisted fiberoptic intubation and for uncomplicated, atraumatic endotracheal tube exchange.Both LMA types have a structure that permits endotracheal intubation. In cases of difficult intubation, these two LMA types can be used. In the literature, there is no study comparing these two LMA types using Aintree catheter.Difficult Airway Society (DAS) published a guide for tracheal intubation in 2011 using Aintree. According to this guide, LMA type LMA Supreme is the most unfavorable for this process. However, there is no research or recommendation on the type of LMA most suitable for use in the literature. In accordance with the data of this study, it will be tried to show which LMA type may be suitable for intubation with Aintree catheter in patients.
Conditions
- Intubation;Difficult
Interventions
- DEVICE
-
LMA protector
In this arm the LMA protector will be inserted. The time from took the LMA to placement of the LMA will be recorded. In patients with adequate ventilation, an Aintree catheter placed on a fiberoptic bronchoscope in LMA will be delivered. Cord vocals will be seen on the monitor and the aintree catheter will be sent into the trachea. After the insertion of the trachea, the fiberoptic bronchoscope and LMA are removed and the patient's intubation tube is advanced through the Aintree catheter to the patient's trachea. Once you have made sure that the tube is in the trachea, it will be removed. The time from insertion of the LMA to placement of the endotracheal tube will be recorded.
- DEVICE
-
I-gel LMA
In this arm the I-gel LMA will be inserted. The time from took the LMA to placement of the LMA will be recorded. In patients with adequate ventilation, an Aintree catheter placed on a fiberoptic bronchoscope in LMA will be delivered. Cord vocals will be seen on the monitor and the aintree catheter will be sent into the trachea. After the insertion of the trachea, the fiberoptic bronchoscope and LMA are removed and the patient's intubation tube is advanced through the Aintree catheter to the patient's trachea. Once you have made sure that the tube is in the trachea, it will be removed. The time from insertion of the LMA to placement of the endotracheal tube will be recorded.
Sponsors & Collaborators
-
Kocaeli Derince Education and Research Hospital
lead OTHER
Principal Investigators
-
Kemal T Saraçoğlu, assoc. prof. · Sağlık Bilimleri Üniversitesi Kocaeli Derince Eğitim ve Araştırma Hastanesi
Study Design
- Allocation
- RANDOMIZED
- Purpose
- OTHER
- Masking
- NONE
- Model
- CROSSOVER
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2018-04-05
- Primary Completion
- 2019-04-05
- Completion
- 2019-07-05
Countries
- Turkey (Türkiye)
Study Locations
More Related Trials
-
Comparison of Endotracheal Intubation Over the Aintree Via the I-gel and Laryngeal Mask Airway Supreme
NCT02476565 ·Status: COMPLETED ·Phase: NA
-
Comparison of Gastric Volume in I-gel and ProSeal Laryngeal Mask Airways
NCT07138092 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Comparison of CTrach, Intubating Laryngeal Mask Airway (ILMA) and I-gel for Tracheal Intubation
NCT00983229 ·Status: COMPLETED ·Phase: NA
-
The Laryngeal Mask Airway in Edentulous Geriatric Patients
NCT02197377 ·Status: COMPLETED ·Phase: NA
-
A Comparison of Supraglottic Airway Devices
NCT02339519 ·Status: COMPLETED ·Phase: PHASE4
-
LMA® Gastro Airway Versus Gastro-Laryngeal Tube in Endoscopic Retrograde Cholangiopancreatography
NCT04196582 ·Status: COMPLETED ·Phase: NA
-
Usage of LMA Protector on Patients Who Undergo Laparoscopic Surgery
NCT03453138 ·Status: COMPLETED ·Phase: NA
-
Comparison of Two Type of Laryngeal Mask : I-Gel & LMA ProSeal
NCT00624403 ·Status: COMPLETED ·Phase: NA
-
The Comparison of the Clinical Efficacy Between I-gel and LMA-Supreme, the Two Most Recently Developed Supraglottic Airway Devices, in Elderly Patients
NCT02026791 ·Status: COMPLETED ·Phase: NA
-
Laryngeal Mask Supreme™ Versus the I-gel™
NCT00653237 ·Status: COMPLETED ·Phase: NA
-
A Study Comparing the Laryngeal Mask Airway Supreme With the Laryngeal Mask Airway Protector In the Ambulatory Surgery Unit
NCT03462550 ·Status: COMPLETED ·Phase: NA
-
Clasic Laryngeal Mask Airway(C-LMA) and I-gel Releated Regurgitation and Complications
NCT01876836 ·Status: UNKNOWN ·Phase: PHASE4
-
I-gel Versus Classic-Laryngeal Mask Airway (C-LMA) as a Conduit for Tracheal Intubation Using Ventilating Bougie
NCT02566135 ·Status: COMPLETED ·Phase: NA
-
Comparison Study of Two Supraglottic Airway Devices Used for Patients Under General Anesthesia
NCT01001078 ·Status: COMPLETED ·Phase: NA
-
Comparison of the I-gel, Supreme and Proseal LMA in Paralyzed Patients
NCT01909297 ·Status: COMPLETED ·Phase: NA
-
Comparison of Clinical Performance of Supraglottic Airway Devices
NCT06850675 ·Status: COMPLETED
-
The Effect of Placement of Proseal Laryngeal Mask Airway With C-Mac Videolaryngoscopy
NCT03852589 ·Status: COMPLETED ·Phase: NA
-
Comparing the Effect of LTS and Air-Q sp3G LMA Use on Gastric Insufflation Using Ultrasound
NCT07196137 ·Status: COMPLETED
-
Comparison Between the I-gel and Protector Supraglottic Airway Devices
NCT06938308 ·Status: RECRUITING ·Phase: NA
-
Safety and Limitation of the 2nd Generation Laryngeal Mask Airway in the Lithotomy Position: An Obsevational Study
NCT05920447 ·Status: COMPLETED
-
Comparison of the GMA-TULIP and I-gel Laryngeal Mask for Airway Management in General Anaesthesia: a Randomized Controlled Trial
NCT07019961 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
A Comparison of the VBM Intubating Laryngeal Tube and the I-Gel
NCT03067246 ·Status: COMPLETED ·Phase: NA
-
Comparison of LMA Proseal and LMA Supreme for Efficient Ventilation During Lateral Positioned Laparoscopic Surgeres
NCT02852135 ·Status: COMPLETED ·Phase: NA
-
Geriatric Patients and Laryngeal Mask Unique
NCT02219282 ·Status: COMPLETED ·Phase: NA
-
Intubation in Morbidly Obese: a Comparison of Airtraq and ILMA
NCT02969889 ·Status: COMPLETED ·Phase: NA