I-gel Versus Classic-Laryngeal Mask Airway (C-LMA) as a Conduit for Tracheal Intubation Using Ventilating Bougie

NCT02566135 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 58

Last updated 2018-07-27

Study results available
· View outcomes & findings →

Summary

Supraglottic Airway devices(SGAs) like I-Gel and C-LMA ( classic laryngeal mask airway ) have been used as a conduit for tracheal intubation using ventilating bougie. General Anaesthesia with tracheal intubation is one of the technique for giving anaesthesia. Tracheal intubation may become difficult sometimes and endangers patients life. Using SGAs as a conduit for tracheal intubation helps in securing airway. This will be further facilitated by using ventilating bougie, as it maintains oxygenation.

Conditions

  • Intubation; Difficult

Interventions

DEVICE

Tracheal Intubation using I-gel and ventilating bougie

Following general anaesthesia I-gel was inserted. After proper placement . ventilating bougie was inserted. Once it's placement is confirmed I-gel was removed keeping the ventilating bougie in situ. Then appropriate sized endotracheal tube was railroaded over ventilating bougie then it (v.bouggie) was removed . Proper placement of endotracheal tube was confirmed by bilateral equal chest excursion and air entry on auscultation, absence of gastric insuffflation sound over epigastrium and 'sine' wave on capnography. Maximum 3 attempts were allowed for I-gel, ventilating bougie and endotracheal tube.

DEVICE

Tracheal Intubation using C-LMA and ventilating bougie

Following general anaesthesia C-LMA was inserted. After proper placement of C-LMA, ventilating bougie was inserted. It's placement was confirmed and C-LMA was removed after deflation of cuff keeping the ventilating bougie in situ. Then appropriate sized endotracheal tube was railroaded over ventilating bougie. It's placement was confirmed by bilateral equal air entry and chest excursion, absence of gastric insufflation sound over epigastrium and 'sine' wave on capnography. Maximum 3 attempts were allowed for C-LMA , ventilating bougie and endotracheal tube.

Sponsors & Collaborators

  • Medical College Baroda

    lead OTHER

Principal Investigators

  • Aditi A Dhimar, M.D.(anaes) · CDSCO

Study Design

Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Model
PARALLEL

Eligibility

Min Age
18 Years
Max Age
60 Years
Sex
ALL
Healthy Volunteers
Yes

Timeline & Regulatory

Start
2014-03-31
Primary Completion
2015-01-31
Completion
2015-02-28