Exploratory Study to Explore the Safety and Efficacy of the HDx Therapy Using Theranova 500 Dialyzer in Comparison to Hemodiafiltration
NCT03499691 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 43
Last updated 2025-03-13
Summary
Today it is well established that middle molecules comprise several compounds that are not effectively removed by high-flux dialyzers, and effective clearance of large middle molecules in the process of dialysis depends on the dialyzer membrane having large enough pore sizes, larger than the conventional high-flux dialyzers. Studies have found associations between levels of large middle molecule uremic toxins and immune dysfunction and inflammation, as well as adverse outcomes. This indicates that dialysis membranes having larger pores, enabling an expanded HD (HDx) with more effective removal of large middle molecules, can have a positive impact on the inflammatory state. While data is starting to appear on the long-term use of the HDx therapy, little is still known on how large middle molecules and inflammation markers are affected over time.
Conditions
Interventions
- DEVICE
-
Theranova 500 medium cut-off dialyzer
The patients randomized in this group using the Theranova 500 medium cut-off dialyzer, and blood flow rate and treatment duration will be maintained stable during the observation period. However, other prescriptions will vary based on the Principal Investigator's (PI's) judgment. If other dialyzers need to be temporarily used during the study period it shall be recorded which alternative dialyzers are used and for how long the study patient is on a different dialyzer. However, prior to Week 12 laboratory assessment it is recommended that the patient undergoes three dialysis sessions on the designated treatment mode.
- DEVICE
-
Hemodiafiltration
The patients randomized in this group using the on-line high-flux HDF dialyzer, in post dilution mode, will continue to receive treatments according to their current treatment prescriptions for the duration of the study.
Sponsors & Collaborators
-
Baxter Healthcare Corporation
collaborator INDUSTRY -
Vantive Health LLC
lead INDUSTRY
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 80 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2018-04-11
- Primary Completion
- 2018-10-04
- Completion
- 2018-10-04
Countries
- Spain
Study Locations
More Related Trials
-
Theranova Randomized, Controlled, Trial (RCT) in China
NCT05309291 ·Status: COMPLETED ·Phase: NA
-
Theranova Versus High-flux Dialyzer on Preservation of Residual Renal Function
NCT04211571 ·Status: COMPLETED ·Phase: NA
-
Study in End Stage Renal Disease (ESRD) Patients on Hemodialysis Comparing the Theranova Dialyzer to Hemodiafiltration
NCT03547336 ·Status: COMPLETED ·Phase: NA
-
Cardiovascular Risk Comparison Between Expanded Hemodialysis Using Theranova and On-line Hemodiafiltration
NCT03448887 ·Status: COMPLETED ·Phase: NA
-
Comparison of MCO HD on Markers of Vascular Health Compared With On-Line Haemodiafiltration
NCT03510520 ·Status: COMPLETED ·Phase: NA
-
Second Clinical Evaluation of THERANOVA-500 Dialyzer in Chronic Hemodialysis (HD)
NCT03618368 ·Status: UNKNOWN ·Phase: NA
-
Efficacy and Safety of Repeated-use Middle Cut Off Membrane Dialyzers in Hemodialysis Patients
NCT06950944 ·Status: COMPLETED ·Phase: NA
-
Characterization of Removal Capacities of the Theranova Membrane by Proteomic Investigations
NCT03137056 ·Status: UNKNOWN ·Phase: NA
-
Theranova vs High-flux HD Comparison
NCT04106310 ·Status: COMPLETED ·Phase: NA
-
Study in End Stage Renal Disease (ESRD) Patients on Hemodialysis to Determine Non-inferiority of the Theranova Dialyzer Compared to the FX80 Dialyzer
NCT03547323 ·Status: COMPLETED ·Phase: NA
-
Comparing Hemodiafiltration with and Without Hemoadsorption
NCT06710834 ·Status: COMPLETED ·Phase: NA
-
Solute Removal With High Volume Hemodiafiltration Versus Long High Flux Hemodialysis
NCT01445366 ·Status: COMPLETED ·Phase: NA
-
Effect of Hemodiafiltration Plus MCOs on Uremic Toxins Removal
NCT03938285 ·Status: UNKNOWN ·Phase: NA
-
Comparison FX CorDiax 60 in Relation to the FX 60-Dialyzer
NCT01534741 ·Status: COMPLETED ·Phase: PHASE4
-
A Randomised, Open-Label, Cross Over Group, Single-Centre Controlled Study To Evaluate The Clinical Performance Of Medium Cut-Off Membrane Dialyser Compared With High Flux Dialyser Among Patients With Chronic Haemodialysis
NCT04160351 ·Status: COMPLETED ·Phase: NA
-
Clearum High Flux Hemodialyzer Used in Hemodialysis for Subjects With End-Stage Renal Disease
NCT04395131 ·Status: COMPLETED ·Phase: NA
-
Efficacy of Uremic Toxins Clearance With Expanded Hemodialysis
NCT04786535 ·Status: UNKNOWN ·Phase: NA
-
A Comparison of Protein-bound and Large Molecular Weight Uremic Toxin Removals With Novel Super High-flux Dialyzer Between Hemodialysis and High Volume Online HDF Modalities
NCT06567483 ·Status: COMPLETED ·Phase: NA
-
Investigation on the Middle Size Molecule Elimination Characteristics of the FXCorDiax 100 in Relation to the FX 100 and the Polyflux 210 H Dialyser
NCT01578421 ·Status: COMPLETED ·Phase: NA
-
Effect of Increased Convective Clearance by On-Line Hemodiafiltration on All Cause Mortality in Chronic Hemodialysis Patients
NCT00205556 ·Status: COMPLETED ·Phase: NA
-
Intradialytic Exercise With Blood Flow Restriction in Hemodialysis Patients
NCT07269379 ·Status: RECRUITING ·Phase: NA
-
HepZero:Heparin Free Dialysis With Evodial
NCT01318486 ·Status: COMPLETED ·Phase: NA
-
Describe the Effect of the Optimized Hemodialysis Technique (HDx) With Medium Cut-Off Membrane on Recovery Time and Quality of Life
NCT05689801 ·Status: UNKNOWN ·Phase: NA
-
Tolerance of "on Line" Hemodiafiltration in Chronic Renal Failure Patients
NCT01327391 ·Status: COMPLETED ·Phase: PHASE4
-
Theranova Dialyzer and Chronic Kidney Disease - Mineral Bone Disorder (CKD-MBD)
NCT03169400 ·Status: UNKNOWN