Comparison of MCO HD on Markers of Vascular Health Compared With On-Line Haemodiafiltration
NCT03510520 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 63
Last updated 2019-08-09
Summary
The aim of this study is to evaluate haemodialysis treatment using a medium cut-off dialysis membrane (Theranova) compared with on-line haemodiafiltration treatment with respect to markers of endothelial health (plasma endothelial microvesicle levels, pro-inflammatory and pro-coagulant markers).
This study will also compare the 2 treatment modalities with respect to several other outcome measures including patient-reported outcome measures, haemodynamic parameters and advanced glycation end-products.
Conditions
Interventions
- DEVICE
-
Medium Cut-Off Haemodialysis
Treatment with medium cut-off haemodialysis using the Theranova dialysis membrane 3 times per week for 6 months
- DEVICE
-
On-Line Haemodiafiltration
Treatment with on-line haemodiafiltration (HDF) 3 times per week for 6 months (Conventional treatment)
Sponsors & Collaborators
-
Manchester Metropolitan University
collaborator OTHER -
Baxter Healthcare Corporation
collaborator INDUSTRY -
Manchester University NHS Foundation Trust
lead OTHER_GOV
Principal Investigators
-
Sandip Mitra, MBBS · Manchester University NHS Foundation Trust
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2018-09-14
- Primary Completion
- 2019-05-09
- Completion
- 2019-05-09
Countries
- United Kingdom
Study Locations
More Related Trials
-
Efficacy and Safety of Repeated-use Middle Cut Off Membrane Dialyzers in Hemodialysis Patients
NCT06950944 ·Status: COMPLETED ·Phase: NA
-
Theranova vs High-flux HD Comparison
NCT04106310 ·Status: COMPLETED ·Phase: NA
-
Effect of Hemodiafiltration Plus MCOs on Uremic Toxins Removal
NCT03938285 ·Status: UNKNOWN ·Phase: NA
-
Comparison of the Clinical Performance of 3 THERANOVA 400 Dialyzer Prototypes With a High-Flux Dialyzer in Hemodialysis Mode
NCT02377570 ·Status: COMPLETED ·Phase: NA
-
Characterization of Removal Capacities of the Theranova Membrane by Proteomic Investigations
NCT03137056 ·Status: UNKNOWN ·Phase: NA
-
12 Weeks of Hemodialysis With Medium Cut-Off Filter Compared to Hemodiafiltration With Standard High-flux Filter.
NCT03416192 ·Status: WITHDRAWN ·Phase: NA
-
Study in End Stage Renal Disease (ESRD) Patients on Hemodialysis to Determine Non-inferiority of the Theranova Dialyzer Compared to the FX80 Dialyzer
NCT03547323 ·Status: COMPLETED ·Phase: NA
-
Comparison of Hemodialysis With Medium Cut-off Dialyzer (Theranova) and High Flux Dialyzer
NCT03211676 ·Status: COMPLETED ·Phase: NA
-
Describe the Effect of the Optimized Hemodialysis Technique (HDx) With Medium Cut-Off Membrane on Recovery Time and Quality of Life
NCT05689801 ·Status: UNKNOWN ·Phase: NA
-
Theranova Versus High-flux Dialyzer on Preservation of Residual Renal Function
NCT04211571 ·Status: COMPLETED ·Phase: NA
-
Safety and Efficacy Evaluation of CO2 Removal in Combination With Continuous Veno-Venous Hemodialysis/Hemodiafiltration Therapy
NCT04871893 ·Status: COMPLETED ·Phase: NA
-
Comparison of Citrate and Heparin Anticoagulation During Hemodialysis With MCO PES-PVP (Theranova) Membrane
NCT04139525 ·Status: UNKNOWN ·Phase: NA
-
Study in End Stage Renal Disease (ESRD) Patients on Hemodialysis Comparing the Theranova Dialyzer to Hemodiafiltration
NCT03547336 ·Status: COMPLETED ·Phase: NA
-
Study to Explore Morbimortality in Patients Dialyzed With the Theranova HDx in Comparison to On-Line-Hemodiafiltration
NCT03714386 ·Status: UNKNOWN ·Phase: NA
-
Comparison of the Impact of Dialysis Treatment Type on Patient Survival
NCT00510549 ·Status: COMPLETED ·Phase: PHASE4
-
Theranova 400 Dialyzer In End Stage Renal Disease (ESRD) Patients
NCT03257410 ·Status: COMPLETED ·Phase: NA
-
High Versus Standard Volume Hemodiafiltration in Asia
NCT02092194 ·Status: UNKNOWN ·Phase: NA
-
A Comparative Study of Two Kinds of Hemodialysis Filters
NCT05899283 ·Status: COMPLETED ·Phase: NA
-
Comparative Effects Of Dialysate Flow Rate And Membrane Packing On The Performance Of Dialyzers Used For Hemodialysis
NCT00636077 ·Status: COMPLETED ·Phase: NA
-
A Prospective Randomized Controlled Trial of Effect of Enhanced External Counter Pulsation to Arterial Stiffness in Chronic Hemodialysis Patient
NCT06608953 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
The Immune System in End Stage CKD Patients - Comparison Among Different Modalities of RRT
NCT04286477 ·Status: UNKNOWN
-
Improving Outcomes in Peritoneal Dialysis
NCT02207751 ·Status: WITHDRAWN
-
MCO Membrane Efficiency in Septic Shock Patients
NCT04834921 ·Status: COMPLETED ·Phase: NA
-
Hemodiafiltration Versus Hemodialysis in Older People
NCT07278973 ·Status: RECRUITING ·Phase: NA
-
Effect of Mixed On-line Hemodiafiltration on Circulating Markers of Inflammation and Vascular Dysfunction
NCT03202212 ·Status: COMPLETED ·Phase: PHASE1/PHASE2