Endoscopic Ultrasound (EUS)-Guided Fine Needle Aspiration (FNA) With Rapid On-site Evaluation (ROSE) of Cytopathology vs. EUS-guided Fine Needle Biopsy (FNB) Alone in the Diagnosis of Pancreatic Solid Lesions
NCT03435588 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 235
Last updated 2020-12-11
Summary
Currently, the best way to evaluate pancreatic masses is through endoscopic-guided needle sampling of the mass to determine the diagnosis by looking at the acquired tissue under a microscope. This is done by inserting a small camera (endoscope) through the mouth of the patient then advanced to the stomach and using ultrasound guidance a sample of the pancreas can be acquired through the stomach. The sampling is usually done with a small needle called fine needle aspiration needle or FNA. FNA alone is sometimes limited due to inadequate acquisition of cells for proper diagnosis under the microscope, which can lead to need for repeat endoscopic procedures and delay in diagnosis and possibly treatment. Rapid on-site evaluation of cytopathology (ROSE) is where a cytopathologist is next to the physician doing the endoscopic procedures and evaluates each sampling performed immediately under the microscope and can give feedback to the endoscopist until enough cells has been acquired for a diagnosis. This method has been shown to increase the ability to diagnose pancreatic cancer but is expensive and requires significant amount of resources. New needles called core needles (fine needle biopsy, FNB) have recently been developed which not only acquires cells but also the entire tissue structure (histology) and has been shown to be also very accurate in the diagnosis of pancreatic cancer.
The purpose of this study is to compare endoscopy-guided biopsy of pancreatic masses with the new core needle (FNB), which can obtain more tissue for diagnosis vs. using a traditional needle (FNA) with the help of an immediate assessment of the obtained samples under the microscope to determine whether enough tissue has been obtained (ROSE). Both approaches have been shown to increase the accuracy of diagnosis in solid pancreatic masses but it is unclear which one is superior. This is a randomized trial meaning that the participants would either undergo biopsy with the new needle or with the traditional needle plus the addition of on-site assessment of the obtained samples. The advantage of the new needle is that it is easy to implement and likely much cheaper. If the investigators can show in our study that the new needles are as accurate as FNA with ROSE then FNB could be implemented across hospitals worldwide in an easier and less expensive fashion.
Conditions
- Solid Pancreatic Tumor
Interventions
- PROCEDURE
-
EUS
Radial endoscopic ultrasound. A special endoscope uses high-frequency sound waves to produce detailed images of the lining and walls of the digestive tract , and allows to take samples from abnormal areas.
- PROCEDURE
-
FNA with ROSE
Endoscopic ultrasound guided biopsy of the pancreas with the traditional fine needle aspirate needle with the addition of rapid on-site cytopathology (cytopathologist looking at each biopsy samples as they are taken): The sampling is done with a small needle called fine needle aspiration needle or FNA. FNA alone is sometimes limited due to inadequate acquisition of cells for proper diagnosis under the microscope, which can lead to need for repeat endoscopic procedures and delay in diagnosis and possibly treatment. Rapid on-site evaluation of cytopathology (ROSE) is where a cytopathologist is next to the physician doing the endoscopic procedures and evaluates each sampling performed.
- PROCEDURE
-
FNB alone
Endoscopic ultrasound guided biopsy with a novel core biopsy needle without on-site cytopathology: New needles called core needles (fine needle biopsy, FNB) have recently been developed which not only acquires cells but also the entire tissue structure (histology).
Sponsors & Collaborators
-
McGill University Health Centre/Research Institute of the McGill University Health Centre
lead OTHER
Principal Investigators
-
Yen-I Chen, MD · McGill University Health Centre/Research Institute of the McGill University Health Centre
Study Design
- Allocation
- RANDOMIZED
- Purpose
- DIAGNOSTIC
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2018-02-14
- Primary Completion
- 2019-12-15
- Completion
- 2019-12-15
Countries
- Canada
Study Locations
More Related Trials
-
Multicentered Prospective Randomized Controlled Trial For Solid Pancreatic Lesions
NCT04841616 ·Status: UNKNOWN ·Phase: NA
-
Impact of Suction in the EUS-guided Fine Needle Biopsy of Solid Pancreatic Lesions
NCT04164017 ·Status: UNKNOWN ·Phase: NA
-
Prospective Evaluation of Diagnostic Accuracy of Endoscopic Ultrasound-guided Fine Needle Aspiration and Biopsy (EUS-FNAB) in the Absence of Rapid Onsite Evaluation
NCT02079285 ·Status: COMPLETED
-
Efficiency Study of the EUS-FNA Needles With and Without a Side Port in Pancreatic Masses
NCT01978808 ·Status: UNKNOWN
-
Standard Versus Fanning Techniques for Endoscopic Ultrasound-Fine Needle Aspiration (EUS-FNA)
NCT01501903 ·Status: COMPLETED ·Phase: NA
-
Artificial Intelligence (AI) Cytopathology Trial
NCT05018663 ·Status: RECRUITING
-
Percutaneous Versus EUS FNAC in Pancreatic Masses
NCT04623749 ·Status: UNKNOWN ·Phase: NA
-
Prospective Study FNB, Is It Time To Abandon Cytological Assessment
NCT04165018 ·Status: COMPLETED
-
On-site Cytopathology EUS-FNA
NCT01386931 ·Status: COMPLETED
-
Prospective Trial of EUS-FNA Versus EUS-FNB Using a Novel Core Biopsy Needle
NCT01769248 ·Status: COMPLETED ·Phase: NA
-
Prospective Comparison of Diagnostic Accuracy Between Contrast-enhanced Harmonic and Conventional EUS-guided Fine-needle Biopsy in Solid Pancreatic Lesions
NCT04924725 ·Status: COMPLETED ·Phase: NA
-
Comparison of EUS-FNB Biopsy Techniques of Solid Pancreatic Lesions
NCT04843956 ·Status: UNKNOWN ·Phase: NA
-
EUS- and US- Guided Biopsy for Pancreatic Lesion
NCT07138976 ·Status: NOT_YET_RECRUITING
-
Comparison of Two Needles (ProCore vs EchoTip) for the Diagnosis of Pancreatic Solid Mass Under EUS
NCT01479803 ·Status: COMPLETED ·Phase: PHASE3
-
The Accurateness of Endoscopic Ultrasound Elastography in the Guidance of EUS-FNA in Solid Pancreatic Lesions
NCT04148755 ·Status: UNKNOWN
-
Diagnostic Efficacy Of 3 EUS-FNB Techniques
NCT05825729 ·Status: RECRUITING ·Phase: PHASE4
-
Yield of Endoscopic Ultrasound Guided Fine Needle Aspiration (EUS-FNA) With and Without the Use of a Stylet in the Biopsy Needle
NCT01241799 ·Status: COMPLETED ·Phase: NA
-
Endoscopic Ultrasound-guided Fine Needle Aspiration of Solid Masses: Histological and Immunohistochemical Evaluation
NCT01437410 ·Status: COMPLETED
-
A Real-world Comparison of FNB and FNA in IHC-required Lesions.
NCT05565066 ·Status: COMPLETED
-
Comparision of EUS-FNB Techniques for Diagnose of Solid Pancreatic Lesions
NCT05549856 ·Status: UNKNOWN ·Phase: NA
-
EUS-FNB for Solid Pancreatic Lesions: Side-fenestrated Vs Fork-tip Needle
NCT03622229 ·Status: COMPLETED ·Phase: NA
-
Conventional Versus Elastography Targeted Endoscopic Ultrasound Fine Needle Aspiration of Solid Pancreatic Lesions
NCT03210948 ·Status: UNKNOWN ·Phase: NA
-
Comparing Methods to Biopsy Pancreas Mass
NCT01663493 ·Status: COMPLETED ·Phase: NA
-
Comparing the Efficacy of Endoscopic FNA vs FNB in Diagnosing Solid Gastrointestinal Lesions
NCT01698190 ·Status: UNKNOWN ·Phase: NA
-
Optimal Number of To-and-fro Motion in EUS-guided Fine Needle Aspiration for Pancreatic Masses
NCT01576497 ·Status: COMPLETED ·Phase: PHASE3