Heart Catheterization Using Magnetic Resonance Imaging (MRI) Fluoroscopy and Passive Guidewires
NCT03152773 · Status: SUSPENDED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 22
Last updated 2026-04-24
Summary
Background:
A heart catheterization is a diagnostic heart procedure used to measure pressures and take pictures of the blood flow through the heart chambers. Magnetic resonance imaging (MRI) fluoroscopy shows continuous pictures of the heart chambers that doctors can watch while they work. Researchers want to test this procedure with catheterization tools routinely used in x-ray catheterization called guidewires. Guidewires will help move the heart catheter through the different heart chambers. Guidewires are usually considered unsafe during MRI because MRI can cause a guidewire to heat while inside the blood vessels and heart. Researchers are testing special low energy MRI settings that allow certain guidewires to be used during MRI catheterization without heating. Using these guidewires during MRI may help to decrease the amount of time you are in the MRI scanner, and the overall time the MRI catheterization procedure takes.
Objectives:
To test if certain MRI settings make it safe to use a guidewire during MRI fluoroscopy.
Eligibility:
Adults 18 and older whose doctors have recommended right heart catheterization.
Design:
Researchers will screen participants by reviewing their lab results and questionnaire answers.
Participants may give 4 blood samples.
Participants will be sedated. They will have a tube (catheter) placed in the groin, arm, or neck if they don t already have one.
Patches on the skin will monitor heart rhythm. Special antennas, covered in pads, will be placed against the body.
Participants will lie flat on a table that slides in and out of the MRI scanner as it makes pictures. Participants will get earplugs for the loud knocking noise. They can talk on an intercom. They will be inside the scanner for up to 2 hours. They can ask to stop at any time.
During a heart catheterization, catheters will be inserted through the tubes already in place. The catheters are guided by MRI fluoroscopy into the chambers of the heart and vessels. The guidewire will help position the catheter.
Conditions
- Pulmonary Artery Hypertension
- Congenital Heart Disease
- Structural Heart Disease
Interventions
- PROCEDURE
-
MRI Heart guidewire catheterization
to conduct left and right heart guidewire catheterization using real-time MRI fluoroscopy in human research subjects already undergoing medically necessary left and right heart catheterization. We will use only passive MRI-compatible catheters and a specific guidewire shown to be safe under specific conditions. Under the conditions of use, the guidewire is not susceptible to heating.
Sponsors & Collaborators
-
National Heart, Lung, and Blood Institute (NHLBI)
lead NIH
Principal Investigators
-
Robert J Lederman, M.D. · National Heart, Lung, and Blood Institute (NHLBI)
Study Design
- Allocation
- NA
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Max Age
- 100 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2017-08-02
- Primary Completion
- 2027-12-01
- Completion
- 2027-12-01
Countries
- United States
Study Locations
More Related Trials
-
Vascular Endothelial Function and Cardiac Resynchronization Response in Patients With Heart Failure
NCT02783716 ·Status: TERMINATED ·Phase: NA
-
MRI-Guided Balloon Angioplasty to Treat Blood Flow Blockage in the Legs
NCT00094783 ·Status: COMPLETED ·Phase: PHASE1
-
Image Fusion of SPECT MPI and Fluoroscopy Venography to Guide LV Lead Placement for Improved CRT Response (GUIDE-CRT II)
NCT03125720 ·Status: COMPLETED ·Phase: NA
-
Cardiac Magnetic Resonance Imaging (CMRI) for Detection of Cardiac Transplant Rejection
NCT01136135 ·Status: COMPLETED
-
Technical Development of Cardiovascular Magnetic Resonance Imaging
NCT04927429 ·Status: RECRUITING
-
MRI Assessment of Patient Suitability for Cardiac Resynchronization Therapy (CRT)
NCT02728336 ·Status: SUSPENDED ·Phase: NA
-
Technical Development of Cardiovascular Magnetic Resonance Imaging
NCT00027170 ·Status: COMPLETED
-
Non-Contrast Magnetic Resonance Angiography Assessment of Patients Referred for Transcatheter Aortic Valve Implantation
NCT02007967 ·Status: TERMINATED
-
Creation of an ECG Database in 3T MRI With Healthy Heart and Several Kind of Cardiac Disease.
NCT02562534 ·Status: TERMINATED ·Phase: NA
-
Validation of Thermometric Cardiac Imaging by MRI
NCT03031587 ·Status: COMPLETED ·Phase: NA
-
Implementation of Non-size Markers Derived From 4D Flow MRI of Patients With Aortic Disease.
NCT02467062 ·Status: COMPLETED ·Phase: NA
-
Magnetocardiography as a Non-Invasive Tool for Detecting Tissue Rejection in Heart Transplant Patients
NCT00169936 ·Status: COMPLETED ·Phase: PHASE3
-
Magnetic Resonance Imaging Development for High Resolution Atrial Structural and Functional Characterization
NCT06617624 ·Status: NOT_YET_RECRUITING
-
Magnetocardiography (MCG) in Subjects Undergoing CT Angiography (CTA)
NCT00574561 ·Status: WITHDRAWN
-
MAGNET CRT Feasibility - Efficiency of LV Lead Placement Comparing Conventional vs. Magnetic Guidance
NCT00370474 ·Status: TERMINATED ·Phase: PHASE4
-
Multimodality Evaluation of Left Ventricular Remodeling In Mitral Regurgitation: A Pilot Study
NCT06770062 ·Status: RECRUITING
-
Intracoronary Thrombus Detection by Magnetic Resonance Imaging
NCT02776657 ·Status: COMPLETED ·Phase: NA
-
Study of Blood Flow in Heart Muscle
NCT00001631 ·Status: COMPLETED ·Phase: PHASE2
-
Using Magnetic Resonance Imaging to Evaluate Heart Vessel Function After Angioplasty or Stent Placement Procedures
NCT00692991 ·Status: COMPLETED
-
Comparison of Magnetic Resonance Coronary Angiography (MRCA) With Coronary Computed Tomography Angiography (CTA)
NCT03768999 ·Status: TERMINATED
-
Magnetic Sensor Validation of Hemodynamic Non-invasive Measurements Pressure During Cardiac Catheterization
NCT05943275 ·Status: UNKNOWN ·Phase: NA
-
Assessment Of MRI In Patients With Implanted Cardiac Devices
NCT02815384 ·Status: WITHDRAWN
-
Manganese-Enhanced Magnetic Resonance Imaging of the Myocardium
NCT03607669 ·Status: COMPLETED
-
Refinement and Assessment of New MRI Technologies for Cardiovascular Exams Using the Phillips CMR Patch
NCT06331507 ·Status: TERMINATED ·Phase: NA
-
Multicenter Imaging in Lead Extraction Study
NCT03772704 ·Status: COMPLETED