Technical Development of Cardiovascular Magnetic Resonance Imaging
NCT00027170 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 8781
Last updated 2021-03-30
Summary
This study will explore new ways of using magnetic resonance imaging (MRI) to evaluate the heart and blood vessels of patients with cardiovascular disease, including better detection of myocardial infarction (heart attack) and blockage of heart and leg arteries.
Patients 18 years of age and older with cardiovascular disease may be eligible for this study.
All participants will have magnetic resonance imaging of the heart. MRI uses a magnetic field and radio waves to show structural and chemical changes in tissues. For the procedure, the patient lies on a table surrounded by a metal cylinder (the scanner). A 'gadolinium contrast' material may be injected into the patient s vein during part of the study to brighten the images. Patients wear earplugs during the scan to muffle loud knocking sounds caused by the electrical switching of the magnetic fields. They will be asked to hold their breath intermittently for 5 to 20 seconds during the scan. They will be monitored with an electrocardiogram (EKG) during the procedure and will be in contact by intercom at all times with the person performing the scan. Patients can request to stop the study and come out of the scanner at any time. The procedure may last from 30 to 90 minutes. An echocardiogram a test that uses sound waves to produce pictures of the heart and blood vessels-may be done to confirm the MRI findings. In addition, patients may undergo one or more of the following optional studies:
* Dobutamine stress MRI - This test uses dobutamine-a medicine that simulates exercise by increasing heart rate and heart function-to detect blockages in the coronary arteries (vessels that supply oxygen and nutrients to the heart) and locate areas of the heart that are permanently damaged, perhaps by a previous heart attack. For this test, MRI pictures of the heart are taken before, during and after administration of dobutamine. Gadolinium may be injected during part of the study to brighten the images. An EKG will be used to monitor the heart during the procedure.
* Vasodilator MRI - The procedure and objectives of this test are the same as those described for dobutamine stress MRI, except that this study uses dipyridamole or adenosine. These drugs dilate blood vessels, causing increased blood flow to the heart.
* Plethysmography MRI - This test determines the presence and severity of narrowing in arteries that supply blood to the leg. Blockage of these vessels often causes pain while walking. This study will compare plethysmography MRI with venous occlusion plethysmography, an older method of measuring blood flow in the legs. For venous occlusion plethysmography, a large blood pressure cuff is placed around the upper leg and a strain gauge (thin elastic band) is placed around the calf. The pressure cuff is inflated very tightly for 5 minutes to block blood flow to the leg, and another pressure cuff over the ankle is also inflated. When the large cuff is deflated, blood rushes to the leg, a smaller cuff is inflated to a low pressure, and the strain gauge measures the maximum blood flow to the leg for 1 or 2 more minutes. This procedure is done once or twice outside the MRI scanner and once or twice inside the scanner. The scans are performed as described above for the dobutamine and vasodilator studies. The strain gauge is not used for plethysmography MRI the MRI pictures are used to measure flow.
Conditions
- Cardiomyopathy
- Congenital Heart Disease
- Cardiovascular Disease
- Cardiac Magnetic Resonance Imaging
- Acute Myocardial Infarction
Interventions
- DEVICE
-
Siemens MRI scanner
Investigational or research MRI coils may be used in the protocol. The coils are noninvasive devices external to the body. The coils act as antennae to receive small radiofrequency signals out of the body. Coils of the type we use are used daily in clinical MRI practice.
Sponsors & Collaborators
-
National Heart, Lung, and Blood Institute (NHLBI)
lead NIH
Principal Investigators
-
Arlene Sirajuddin, M.D. · National Heart, Lung, and Blood Institute (NHLBI)
Eligibility
- Min Age
- 18 Years
- Max Age
- 100 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2001-11-26
- Primary Completion
- 2018-04-05
- Completion
- 2020-11-19
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
Intracoronary Thrombus Detection by Magnetic Resonance Imaging
NCT02776657 ·Status: COMPLETED ·Phase: NA
-
Technical Development of Cardiovascular Magnetic Resonance Imaging (CMR) Using a Low Specific Absorption Rate (SAR) Scanner System
NCT03331380 ·Status: RECRUITING ·Phase: NA
-
Study of Blood Flow in Heart Muscle
NCT00001631 ·Status: COMPLETED ·Phase: PHASE2
-
Longitudinal Validation of CIRC Technologies
NCT07081711 ·Status: NOT_YET_RECRUITING
-
Technical Evaluation of Cardiovascular Magnetic Resonance Imaging and Spectroscopy
NCT00001874 ·Status: COMPLETED
-
Safety and Effectiveness of Coronary Magnetic Resonance Angiography (CMRA) Imaging
NCT00001633 ·Status: COMPLETED ·Phase: PHASE2
-
New Heart Imaging Techniques to Evaluate Possible Heart Disease
NCT01399385 ·Status: RECRUITING ·Phase: NA
-
Detection and Significance of Heart Injury in ST Elevation Myocardial Infarction.
NCT02072850 ·Status: ACTIVE_NOT_RECRUITING
-
Cardiac MR of Subclinical CVD: Impact of Age
NCT00041418 ·Status: COMPLETED
-
Multimodal Imaging Assessment After Revascularization in Patients With Acute Myocardial Infarction
NCT07130409 ·Status: RECRUITING
-
Real-time MRI Right Heart Catheterization Using Passive Catheters
NCT01287026 ·Status: COMPLETED ·Phase: PHASE1/PHASE2
-
Development of CIRC Technologies
NCT05654272 ·Status: RECRUITING
-
Magnetic Resonance Angiography to Diagnose Atherosclerotic Disease
NCT00382564 ·Status: COMPLETED
-
Validation of MRI Measurement of Cardiac Blood Flow
NCT00417625 ·Status: COMPLETED
-
Characterization of Patients With Uncommon Presentations and/or Uncommon Diseases Associated With the Cardiovascular System
NCT01143454 ·Status: RECRUITING
-
Magnetic Resonance Imaging to Detect Blood Vessel Inflammation in Patients Undergoing Peripheral Balloon Angioplasty
NCT00004549 ·Status: COMPLETED ·Phase: PHASE1
-
Magnetic Resonance Imaging (MRI) Viability: Comparison of Myocardial Viability by Positron Emission Tomography and MRI
NCT00166179 ·Status: COMPLETED
-
Refinement and Assessment of New MRI Technologies for Cardiovascular Exams Using the Phillips CMR Patch
NCT06331507 ·Status: TERMINATED ·Phase: NA
-
Magnetic Resonance Imaging of Narrowed Arteries
NCT00029575 ·Status: COMPLETED ·Phase: PHASE1
-
PET-MR Imaging of Coronary Atherothrombosis
NCT03618303 ·Status: COMPLETED ·Phase: NA
-
Inflammatory Cell Trafficking After Myocardial Infarction
NCT01127113 ·Status: WITHDRAWN ·Phase: NA
-
Development of 3T Magnetic Resonance Research Methods for NIA Studies
NCT01324206 ·Status: RECRUITING
-
A 10-Minute Cardiovascular Magnetic Resonance Protocol for Cardiac Disease
NCT04464655 ·Status: RECRUITING
-
Using Cardiac MRI to Predict Outcomes in Patients With STEMI
NCT07072858 ·Status: RECRUITING
-
Magnetic Resonance Imaging Development for High Resolution Atrial Structural and Functional Characterization
NCT06617624 ·Status: NOT_YET_RECRUITING