Whole-Heart Myocardial Blood Flow Quantification Using MRI
NCT03064295 · Status: UNKNOWN · Type: OBSERVATIONAL · Enrollment: 160
Last updated 2023-02-08
Summary
This study hopes to provide significant technical improvement in a Myocardial Blood Flow (MBF) cardiac magnetic resonance (CMR) quantification technique to address challenges and technical limitations for MBF CMR. By developing and validating novel techniques to improve first-pass perfusion (FPP) cardiac MR, we propose to increase diagnostic accuracy by minimizing false positives and false negatives, allow for better evaluation and accurate quantification of total ischemic burden and reduce image and motion-induced artifacts.
The broad, long-term objective of the proposed project is to improve the prognosis of patients with myocardial ischemia caused by coronary artery disease (CAD) or coronary microvascular dysfunction (CMD).
Conditions
- Coronary Artery Disease
- Coronary Microvascular Disease
Interventions
- DEVICE
-
Myocardial Perfusion Cardiac MRI.
MRI with administration of a contrast drug and a stress agent, if no contraindications are present. The gadolinium based contrast agent to be used in this study is either Gadavist (up to 0.2 mL/kg body weight (0.2 mmol/kg) or MultiHance (0.2 mmol/kg) The IV stress agent is regadenoson (0.4mg/5ml bolus) or adenosine (dosage based on subject's weight and is set at 140mcg/kg/min
- DRUG
-
Contrast
The intravenous gadolinium based contrast agent to be used in this study is either Gadavist (up to 0.2 mL/kg body weight (0.2 mmol/kg) or MultiHance (0.2 mmol/kg)
- DRUG
-
Pharmacologic Stress Agent
The stress agent administered intravenously is regadenoson (0.4mg/5ml bolus) or adenosine (dosage based on subject's weight and is set at 140mcg/kg/min
Sponsors & Collaborators
-
National Heart, Lung, and Blood Institute (NHLBI)
collaborator NIH -
Cedars-Sinai Medical Center
lead OTHER
Principal Investigators
-
Zhaoyang Fan, PhD · Cedars-Sinai Medical Center
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2018-03-01
- Primary Completion
- 2025-01-01
- Completion
- 2025-01-01
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
CMR-derived Quantitative Perfusion for Prediction of FFR
NCT07018778 ·Status: NOT_YET_RECRUITING
-
Advanced Cardiac Magnetic Resonance Imaging for Assessment of Obstructive Coronary Artery Disease: ADVOCATE-CMR
NCT06419894 ·Status: NOT_YET_RECRUITING
-
Comparison of Cardiac Computed Tomography and Vasodilator Stress Magnetic Resonance Imaging Perfusion in Patients With Prior Equivocal Stress Test for Detection of Coronary Artery Disease
NCT00929227 ·Status: COMPLETED
-
Impact of Coronary Artery Stenting on Quantitative Myocardial Blood Flow and Health Status
NCT04475094 ·Status: UNKNOWN
-
Magnetocardiography (MCG) in the Diagnosis of Chest Pain Syndrome
NCT00572949 ·Status: WITHDRAWN
-
Application of speCtraL Computed tomogrAphy to impRove specIficity of Cardiac compuTed tomographY
NCT03139006 ·Status: UNKNOWN
-
Safety and Effectiveness of Coronary Magnetic Resonance Angiography (CMRA) Imaging
NCT00001633 ·Status: COMPLETED ·Phase: PHASE2
-
Intraprocedural Determination of Myocardial Vitality Using 2 Different Imaging Methods
NCT01934699 ·Status: UNKNOWN ·Phase: NA
-
Cardiac Magnetic Resonance Imaging for Detecting Endothelial Dysfunction
NCT00808535 ·Status: UNKNOWN
-
Myocardial Blood Volume Measurement by Real-Time Myocardial Perfusion Echocardiography Correlates to Myocardial Compressibility by Cardiac Magnetic Resonance Imaging in Healthy Subjects
NCT04724304 ·Status: COMPLETED ·Phase: NA
-
The CZT Dynamic Myocardial Perfusion Imaging
NCT02697760 ·Status: COMPLETED
-
Comparison of Quantitative MRI Perfusion Methods With Quantitative PET Perfusion Imaging
NCT02608944 ·Status: WITHDRAWN ·Phase: NA
-
Technical Development of Strain Rate Echocardiography
NCT00075920 ·Status: COMPLETED
-
Magnetocardiography (MCG) in Subjects Undergoing CT Angiography (CTA)
NCT00574561 ·Status: WITHDRAWN
-
HeartFlowNXT - HeartFlow Analysis of Coronary Blood Flow Using Coronary CT Angiography
NCT01757678 ·Status: COMPLETED ·Phase: NA
-
Cardiac MR (CMR) in Cardiac Resynchronization Therapy Non-responders
NCT01367691 ·Status: TERMINATED ·Phase: NA
-
Complementary Investigation of Perfusion and Anatomy Measures of the Heart With MRI and Combined PET/MRI
NCT05609214 ·Status: RECRUITING
-
Exercise Cardiac Magnetic Resonance Imaging Accuracy for Cardiovascular Stress Testing
NCT01592565 ·Status: COMPLETED ·Phase: NA
-
Detection and Significance of Heart Injury in ST Elevation Myocardial Infarction.
NCT02072850 ·Status: ACTIVE_NOT_RECRUITING
-
CMR for Prognosis Assessment in NSTEMI
NCT03516578 ·Status: COMPLETED
-
Technical Development of Cardiovascular Magnetic Resonance Imaging
NCT00027170 ·Status: COMPLETED
-
Stress Testing and Cardiac Magnetic Resonance
NCT00871260 ·Status: COMPLETED ·Phase: PHASE4
-
Quantification of Mitral Regurgitation Using 4D MRI Flow : Comparison With 2D MRI Flow and Echocardiography Using the Evolution of Left Ventricular Remodeling as a Reference
NCT07066904 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Myocardial Perfusion Imaging Galmydar Rest/Stress
NCT05625490 ·Status: COMPLETED ·Phase: EARLY_PHASE1
-
Quantitative Cardiac Parametric Mapping
NCT02855554 ·Status: RECRUITING ·Phase: NA