Comparison of Adenoma Detection Miss Rates at Colonoscopy Associated With Different Withdrawal Times
NCT01802008 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 200
Last updated 2015-04-30
Summary
The objective of this study is to determine the optimal withdrawal time for colonoscopy. A 6-minute withdrawal time is currently the standard of care but has only been evaluated in an observational fashion. The investigators believe that this should be validated in a standardized fashion. If the benefits of a 6 minute withdrawal are proven in this study (ie a low polyp/adenoma miss rate and a high polyp/adenoma detection rate), then this will support widespread adoption of a 6 minute withdrawal as the standard of care. This in turn may decrease the occurence of 'interval colon cancers', which are early colon cancers arising in subjects despite their having undergone colonoscopy. Our hypothesis is that the polyp/adenoma detection rate will be unacceptably low and the polyp/adenoma miss rate will be unacceptably high in the 3-minute withdrawal group when compared to the 6-minute withdrawal group.
Conditions
- Adenoma and/or Adenocarcinoma
- Adenoma
Interventions
- PROCEDURE
-
3-minute withdrawal time
For subjects randomized to the 3-minute withdrawal time, advancement to the cecum will be followed by segmental withdrawal in each of 3 segments of the examined colon. Each segment will be examined over 1 minute, followed by a "second look" over each segment over 2 minutes by the same endoscopist.
- PROCEDURE
-
6-minute withdrawal time
For subjects randomized to the 6-minute withdrawal, advancement to the cecum will be followed by segmental withdrawal in each of 3 segments of the examined colon. Each segment will be examined over 2 minutes, followed by a "second look" over each segment over 2 minutes by the same endoscopist.
Sponsors & Collaborators
- lead OTHER
Principal Investigators
-
Subhas Banerjee, M.D. · Stanford University
Study Design
- Allocation
- RANDOMIZED
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2012-09-30
- Primary Completion
- 2013-08-31
- Completion
- 2013-08-31
Countries
- United States
Study Locations
More Related Trials
-
Adenoma Detection Rate With Position Change at Colonoscopy
NCT00234650 ·Status: COMPLETED ·Phase: NA
-
The Utility of Timed Segmental Withdrawal During Screening Colonoscopy
NCT02132455 ·Status: COMPLETED ·Phase: NA
-
The Effect of Taking Break During Colonoscopy Session on Adenoma Detection, a Prospective, Randomized Control Study
NCT01989650 ·Status: COMPLETED ·Phase: NA
-
The Impact of Active Nurse Participation on Adenoma Detection During Routine Colonoscopy
NCT00859625 ·Status: COMPLETED ·Phase: NA
-
Factors Associated With Short Withdrawal Time and Polyp Detection Rate During Colonoscopy
NCT01487356 ·Status: COMPLETED
-
Does Inspection of Colonic Mucosa During Insertion Improve Adenoma Detection?
NCT03254030 ·Status: COMPLETED ·Phase: NA
-
Adenoma Detection by Polypectomy During Both Insertion and Withdrawal
NCT01925833 ·Status: COMPLETED ·Phase: NA
-
Impacts of Inspection During Instrument Insertion on Colonoscopy Quality
NCT03444090 ·Status: COMPLETED ·Phase: NA
-
A Comparison of Methods to Detect Polyps During Colonoscopy
NCT01025960 ·Status: COMPLETED ·Phase: NA
-
Comparing the Adenoma Detection Rate With Air Insufflation, Water Immersion and Water Exchange
NCT01894191 ·Status: COMPLETED ·Phase: NA
-
Cap-fitted Colonoscopy: a Randomized, Tandem Colonoscopy Study of Adenoma Miss Rates
NCT00577083 ·Status: COMPLETED ·Phase: NA
-
A Comparison of Two Colonoscopic Withdrawal Techniques
NCT01554098 ·Status: COMPLETED ·Phase: PHASE4
-
Effect of Single Colonoscopy on Colorectal Adenomas Detection
NCT02693886 ·Status: UNKNOWN
-
The Effect of Segmental Re-examination of Colon for Adenoma Detection in Colonoscopy
NCT03268200 ·Status: COMPLETED ·Phase: NA
-
Explore the Relationship Between the Percentage of Colonoscopy Withdrawal Overspeed and the ADR
NCT05444166 ·Status: UNKNOWN
-
Comparison of Adenoma Detection Rate Among Water, Carbon Dioxide and Air Methods of Minimal Sedation Colonoscopy
NCT01782014 ·Status: TERMINATED ·Phase: PHASE3
-
The Impact of Distraction on Adenoma Detection Rate
NCT02978664 ·Status: COMPLETED ·Phase: NA
-
The Effect of Bowel Preparation Status on the Polyp Missing Rate
NCT00988676 ·Status: COMPLETED
-
Trainee Participation Increases Colon Adenoma Detection Rate
NCT03908229 ·Status: COMPLETED ·Phase: NA
-
Endocuff-assisted vs. Standard Colonoscopy
NCT02340065 ·Status: COMPLETED ·Phase: NA
-
The Impact of Experienced Endoscopy Nurse Participation on Polyp and Adenoma Detection During Colonoscopy
NCT02292563 ·Status: COMPLETED ·Phase: NA
-
A Repeated Instruction by Telephone on the Day Before Colonoscopy to Patients Undergoing Colonoscopy
NCT01584817 ·Status: COMPLETED ·Phase: NA
-
Randomized Trial Comparing Fecal Testing (FIT) to Colonoscopy for Post-polypectomy Surveillance
NCT06983639 ·Status: RECRUITING ·Phase: NA
-
Position Changes During Colonoscope Withdrawal and Polyp Detection
NCT01395173 ·Status: COMPLETED ·Phase: NA
-
Effectiveness of Using the Speedometer During Colonoscopy
NCT04710251 ·Status: UNKNOWN ·Phase: NA