Age-adjusted D-dimer Cut-off Levels to Rule Out Pulmonary Embolism
NCT01134068 · Status: COMPLETED · Phase: PHASE4 · Type: INTERVENTIONAL · Enrollment: 3306
Last updated 2015-05-28
Summary
Suspected pulmonary embolism (PE) is a frequent clinical problem and remains a diagnostic challenge. The diagnostic approach of PE relies on sequential diagnostic tests, such as plasma D-dimer measurement, multi-slice computed tomography (MSCT) and pulmonary angiography. In addition, the diagnostic workup is usually stratified according to the clinical probability of pulmonary embolism. Clinical probability has a fair predictive accuracy either evaluated implicitly or by clinical prediction rules1 and is useful for identifying patients with a low prevalence of pulmonary embolism who can be usually fully investigated by non invasive tests.The D-dimer test has been extensively evaluated in the exclusion of pulmonary embolism, particularly in outpatients. ELISA D-dimer and second-generation latex agglutination (immuno-turbidimetric tests) have a remarkably high sensitivity and have been proved safe first-line tests in association with clinical probability to rule out pulmonary embolism in outcome studies. The clinical usefulness of D-dimer is defined by the proportion of patients in whom pulmonary embolism may be ruled out by a normal result and it is determined by the specificity. However, ELISA and second-generation latex agglutination (immuno-turbidimetric tests) tests have a quite limited overall specificity of around 35% to 40%. Therefore, many investigators tried to increase the D-dimer thresholds in particular in elderly patients to increase the rate of patients in whom the diagnosis could be excluded by this easy and inexpensive test. Several studies have shown that D-dimer levels increase with age and which turns in a decreased specificity of the D-dimer test at the usual threshold in the elderly, and thus to a less useful test to exclude PE in older patients. Indeed, ELISA D-dimer is able to rule out PE in 60% of patients aged less than 40 years, but in only 5% of patients above the age of 80.8 In this study, raising the cut-off value to various points between 600 ng/ml and 1000 ng/ml increased specificity, but this came at the cost of safety with more false negative test results. In this analysis, however, no stratification was made for clinical probability and the sample was small.
Recently, the investigators retrospectively assessed the value of a progressive cut-off adjusted to age in a wide sample of 1712 patients. This "new" cut-off was defined for D-Dimer test positivity in each patient by multiplying patient's age by 10. All patients with a D-Dimer level below 500mg/ml, and all patients above 50 years whose D-Dimer levels were inferior to their age multiplied by 10 were considered as having a negative D-Dimer test. The exact derivation and validation of this "new" D-dimer cut-off is described hereafter. Using the conventional cutoff, the VIDAS® D-Dimer test was negative (below 500 mg/ml) in 512/1712 patients (29.9%) and none had PE during initial workup or the three-month follow-up period.
Using the cutoff adjusted to age (cutoff for D-Dimer test positivity equals age multiplied by ten, in mg/ml), the figure was as follows. D-Dimer levels were below the adjusted cutoff in 615/1712 patients (35.9%, number needed to test 2.8). This represented a statistically significant 20.1% increase in the number of patients in whom the D-Dimer test was considered as negative, p=0.0002. Of these 615 patients, 5 had PE during initial workup (0.8%, 95 percent confidence interval 0.4 to 1.9%).
These data suggest that adopting this progressive cut-off in patients above 50 years, could increase of about 20% the number of patients in whom PE could be excluded without further testing, with an acceptable safety profile as the three-month thromboembolic rate remained very low.
Therefore, the investigators plan a prospective outcome study in which this progressive or "new" cut-off (age X 10 ng/ml) in patients above 50 years will be used. In this multicentre study, clinical probability will be assessed by the simplified revised Geneva revised score (Table 1) and an ELISA D-dimer test will be performed \[Vidas D-Dimer Exclusion® test (Biomérieux, Marcy l'Etoile, Paris, France)\]. Patients with a non high clinical probability with the simplified revised Geneva score and a normal "new" D-dimer cut-off with the Vidas D-dimer Exclusion®, (Biomerieux, Marcy l'Etoile, France) will be considered as not having PE, and will be followed for three-months to assess possible VTE recurrences. The main outcome will be the rate of thromboembolic events during a formal 3-month follow-up in patients not anticoagulated on the basis of this strategy. Patients with positive D-dimers will be investigated with MSCT as currently admitted.
Conditions
Interventions
- OTHER
-
Evaluation of a modified DD cut-off to rule out PE
Evaluation of a modified DD cut-off to rule out PE
Sponsors & Collaborators
-
University Hospital, Brest
collaborator OTHER -
University Hospital, Angers
collaborator OTHER_GOV -
Academisch Medisch Centrum - Universiteit van Amsterdam (AMC-UvA)
collaborator OTHER -
Marc Righini
lead OTHER
Principal Investigators
-
Marc Righini, MD · University Hospital, Geneva
-
Grégoire Le Gal, Prof · University Hospital, Brest
-
Renée Douma, MD · Amsterdam University Hospital
-
Pierre-Marie Roy, Prof · Angers University Hospital
Study Design
- Allocation
- NON_RANDOMIZED
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2010-10-31
- Primary Completion
- 2013-07-31
- Completion
- 2013-12-31
Countries
- France
- Netherlands
- Switzerland
Study Locations
More Related Trials
-
Diagnostic Accuracy of Arterial-alveolar Oxygen Gradient in Low Risk Patients With Suspected Pulmonary Embolism
NCT06043726 ·Status: UNKNOWN
-
Safety of a Diagnostic Strategy With D-Dimer Testing for PE
NCT00182221 ·Status: COMPLETED ·Phase: PHASE3
-
Pulmonary Perfusion by Iodine Subtraction Mapping CT Angiography in Acute Pulmonary Embolism
NCT03579849 ·Status: COMPLETED ·Phase: NA
-
Ruling Out Pulmonary Embolism During Pregnancy:a Multicenter Outcome Study
NCT00771303 ·Status: COMPLETED
-
CTEPH Identification an Standard Computerised Tomography Pulmonary Angiography in Pulmonary Embolism Patients
NCT03083093 ·Status: COMPLETED
-
V/Q SPECT for Diagnosis of Pulmonary Embolism
NCT01183026 ·Status: COMPLETED
-
A Study to Evaluate the Safety of Withholding Anticoagulation in Patients With Subsegmental PE Who Have a Negative Serial Bilateral Lower Extremity Ultrasound
NCT01455818 ·Status: COMPLETED
-
Exclusion of Venous Thrombo-Embolism With a New Clinical Decision Support
NCT06480994 ·Status: RECRUITING
-
Accuracy of the D-Dimer Assay for the Exclusion of Pulmonary Embolism in a High Risk Oncologic Population
NCT00615147 ·Status: COMPLETED
-
Incidence of Acute Pulmonary Embolism in Covid-19 Patients on CT Angiography and Relationship to D-dimer Levels
NCT04373486 ·Status: COMPLETED
-
Iodine Mapping Using Subtraction in Pulmonary Embolism CT Versus Dual-Energy CT
NCT02890706 ·Status: COMPLETED ·Phase: NA
-
Adjust-Unlikely PE
NCT05708794 ·Status: COMPLETED
-
Correlation Between Computer Tomography Angiography and D-Dimer Level for the Diagnosis of Pulmonary Embolism
NCT05862220 ·Status: COMPLETED
-
Assessing the Prognosis of Pulmonary Embolism Using Clinical and Imaging Biomarkers (Retrospective & Prospective )
NCT00805246 ·Status: COMPLETED
-
STA®-Liatest®D-Di-Exclusion of Venous Thromboembolism
NCT01221805 ·Status: COMPLETED
-
Non-invasive Diagnosis of Pulmonary Embolism by Use of Biomarkers in Exhaled Breath
NCT06135220 ·Status: COMPLETED
-
Comparison of 3 Diagnostic Strategies of PE: Planar V/Q Scan, CTPA, and V/Q SPECT.
NCT02983760 ·Status: TERMINATED ·Phase: NA
-
Effect of a Global Simplified Strategy on Thromboembolic Events in Emergency Department Patients with Suspected Pulmonary Embolism
NCT06190392 ·Status: COMPLETED ·Phase: NA
-
Emergency Medicine Pulmonary Embolism Testing Multicentre Study
NCT06320236 ·Status: RECRUITING
-
Frequency of Diagnostic Symptomatic Pulmonary Embolism's in Patients Hospitalized for Clinical Exacerbation of Chronic Obstructive Pulmonary Disease (COPD)
NCT02035293 ·Status: COMPLETED ·Phase: NA
-
Lung Scintigraphy for Pulmonary Embolism Diagnosis in COVID-19 Patients.
NCT05353608 ·Status: COMPLETED
-
Prospective Investigation of Pulmonary Embolism Diagnosis (PIOPED)
NCT00000566 ·Status: COMPLETED ·Phase: PHASE3
-
Ga68 V/Q PET/CT for Pulmonary Embolism Diagnosis: a Diagnostic Accuracy Study vs CT Pulmonary Angiography
NCT04179539 ·Status: COMPLETED ·Phase: NA
-
Soluble Fibrin for Diagnosing Pulmonary Embolism
NCT02438462 ·Status: COMPLETED
-
Two-Site Compression POINt-OF-CARE Ultrasonography for DVT
NCT03056196 ·Status: UNKNOWN