Champy Versus AO for Mandible Fractures
NCT00628849 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 126
Last updated 2013-11-21
Summary
Patients who sustain a broken lower jaw have traditionally been treated in one of three ways. The first involves having their teeth and jaws being wired together for a period of 4 to 6 weeks in order to allow the broken jaw to heal. The second and third ways involve a surgical procedure that requires exposing the broken bones and stabilizing them with metal plates and screws that allow the patient to be able to function relatively normally during the healing period. One surgical method uses small plates and screws while the alternate method uses large plates and screws. Currently there are two schools of thought with respect to what plates and screws should be used. One group supports the use of large rigid plates due to the increased strength of the plate. The use of the larger and stronger plates is the principle behind the AO technique, which was originally developed in the 1970's in Switzerland and is now the more popular technique in the USA. The other group supports the use of smaller plates and screws which must be placed in certain anatomical positions to allow the natural muscular forces that exist on the jaw to stabilize the break and facilitate complete healing of the broken bone. This technique was developed in France by Maxime Champy in the 1970's and is the standard of care throughout Australasia and parts of Europe. This technique is simpler, quicker and cheaper. The need for patients to maintain a diet with softer foods is considered by many to be important for success if the less rigid and smaller plates are going to be used. Many critics of the Champy technique feel that less compliant patient populations as might be seen in a county hospital make the technique less readily suited to these populations. This is contrary to published data from Europe, Australia and recently the USA.
The question of interest is whether the smaller plates and screws are equally as effective in the treatment of broken lower jaws in an urban county hospital? If they are equally effective, then is there any benefit in terms of fewer patient complications and decreased health costs? If the smaller plates and screws are not adequate, then will a modification of the original Champy technique improve their usefulness? Patients who present with a broken lower jaw who require surgery will be treated in one of three ways. Some patients will be treated with the larger plates and screws by an attending surgeon who routinely uses large plates and screws for broken lower jaws. Another group of patients will be treated with the smaller plates and screws using the Champy principles. A third group of patients will also be treated with the smaller plates and screws but using a modification of the original Champy technique that involves the use of additional small plates and screws for added stability. Patients will then be followed over a three month period to evaluate for healing of the broken jaw. The three techniques will be then be compared.
Larger plates/ screws and the smaller plates/ screws are both the standard of care. Regional differences throughout the USA has continued to ensure differences of opinion with regard to which technique is better although historically the larger plates/screws has been more popular in the USA.
Conditions
- Mandibular Injuries
Sponsors & Collaborators
-
Emory University
lead OTHER
Principal Investigators
-
Gary F Bouloux, MD, DDS · Emory University
Eligibility
- Min Age
- 11 Years
- Max Age
- 89 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2007-02-28
- Primary Completion
- 2009-06-30
- Completion
- 2009-06-30
Countries
- United States
Study Locations
More Related Trials
-
InterFlex Plate Versus Conventional Miniplates in the Management of Anterior Mandibular Fractures.
NCT06740292 ·Status: COMPLETED ·Phase: PHASE4
-
Reconstruction of Deficient Maxillary Ridges Using Retromolar Blocks With and Without Collagen Membrane
NCT06900933 ·Status: RECRUITING ·Phase: NA
-
Assessment of Maximal Incisal Opening Using Patient Specific Titanium Eminoplasty Versus Inlay Autogenous Bone Graft for Treatment of Chronic Mandibular Condylar Dislocation
NCT03728270 ·Status: UNKNOWN ·Phase: NA
-
3D Printed Models for Mandibular Fracture Repair
NCT05733221 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Posterior Mandibular Ridge Augmentation Using Mineralized Plasmatic Matrix Versus Autogenous Bone Graft
NCT02998632 ·Status: UNKNOWN ·Phase: NA
-
Comparison of Amnion Chorion Membrane vs. Dense Polytetrafluoroethylene Membrane in Ridge Preservation Procedures
NCT02602223 ·Status: COMPLETED ·Phase: PHASE2
-
Marginal Bone Changes in Fixed All-on-Four Mandibular Prosthesis Using OT Bridge Attachment System
NCT05924386 ·Status: RECRUITING ·Phase: NA
-
Mandibular Reconstruction Bone Plate
NCT06099431 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Tricalcium Phosphate and Chitosan as Bone Regenerator Versus Autologous Graft in Surgery for Mandibular Fracture
NCT02081885 ·Status: COMPLETED ·Phase: PHASE3
-
Clinical and Radiographical Assessment of Patients With Sub-condylar Fracture Using Polyetheretherketone (PEEK) Trapezoidal Plates Versus Titanium Trapezoidal Plates
NCT06940115 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Clinical Assessment of Computer-assisted PEEK Versus Conventional Titanium Plates on Mandibular Body Fractures
NCT03466190 ·Status: UNKNOWN ·Phase: NA
-
Custom-Made 3D PEEK for Fixation of Mandibular Angle Fractures.
NCT07156812 ·Status: COMPLETED ·Phase: PHASE4
-
Evaluating the Impact of Prefabricated Acrylic Splints on Premaxillary Stability in Alveolar Cleft Bone Graft Repairs: a Randomized Controlled Trial
NCT06807645 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Ridge Preservation Comparing the Healing With or Without a Barrier Membrane
NCT02798887 ·Status: COMPLETED ·Phase: NA
-
Comparison of Calcium Phosphate Cement With Patient-specific Implants for Cranial Reconstruction
NCT03841643 ·Status: COMPLETED ·Phase: PHASE3
-
Accuracy and Outcome of Computer-assisted Surgery for Bony Micro-vascular Reconstruction in the Head and Neck Region
NCT03054012 ·Status: COMPLETED
-
z Mini-plate With Lingual Extension Versus Conventional 2 Mini Plates
NCT06898710 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Efficacy of Transoral Versus Transbuccal Technique for Fixation of Mandibular Angle Fracture
NCT06622642 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Bone Augmentation Using Particulated Biomaterial and Autogenous Bone, Stabilized by Collagen Membrane and Pins (PaMP)
NCT02406924 ·Status: UNKNOWN ·Phase: NA
-
A 3D Analysis of Mandibular Plating Strategies in Oromandibular Reconstruction.
NCT03550053 ·Status: COMPLETED ·Phase: NA
-
Effects of Bone Graft Placement at Implant Installation on Buccal Plate Stability
NCT01245920 ·Status: WITHDRAWN ·Phase: NA
-
Assessment of Serum Concentration of Interleukin-17 and Osteoprotegerin in Response to Surgical Trauma Induced by Management of Mandibular Fractures Via Intraoral Versus Extraoral Approaches: Prospective Cohort Study
NCT06349135 ·Status: NOT_YET_RECRUITING
-
Ascending Ramus Versus Chin Cortical Plates for Reconstruction of Atrophic Maxilla
NCT03629860 ·Status: UNKNOWN ·Phase: NA
-
Bone Regeneration With Mesenchymal Stem Cells
NCT02755922 ·Status: COMPLETED ·Phase: PHASE3
-
BoneTape Feasibility Trial
NCT06600854 ·Status: RECRUITING ·Phase: NA