Biventricular Pacing After Cardiopulmonary Bypass

NCT00498940 · Status: TERMINATED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 111

Last updated 2018-02-22

Study results available
· View outcomes & findings →

Summary

The purpose of this study is to investigate the efficacy of optimized temporary biventricular pacing (BiVP) in patients undergoing open-heart surgery with preoperative LV dysfunction and an intraventricular conduction delay. This study will compare extended temporary biventricular pacing versus standard of care by assessing patients randomized to the two groups, from the conclusion of cardiopulmonary bypass, until the conclusion of pharmacologic circulatory support in the intensive care unit. In addition, effects of biventricular pacing will be tested in all patients, at three time points, using different measures of blood flow. Results from this research will demonstrate whether temporary BiVP improves cardiac output after open-heart surgery and whether ventricular pacing optimization increases cardiac output in this setting. Success would lead to the development of recommendations for use of BiVP postoperatively and would stimulate the development of pacemakers with appropriate features.

The primary hypothesis is that the optimum pacing protocol (POPT) will increase cardiac index (CI) by 15% (from approximately 2.30 to 2.64 L/min/m2) compared to standard of care as measured by thermodilution 12-24 hours postoperatively. Secondary objectives include defining POPT at three time points within 24 hours of surgery. The investigator will examine which forms of cardiac dysfunction benefit from temporary pacing using direct and indirect measures of perfusion and cardiac function. The investigator will also analyze survival, length of stay, incidence of arrhythmias, and cost of postoperative care.

Conditions

Interventions

DEVICE

Optimization Testing

Atrioventricular (AVD) and interventricular (VVD) delays and left ventricle lead site location were optimized after weaning off bypass (Phase I), after sternal closure (Phase II), and 12 to 24 hours (Phase III) after bypass. Intrinsic heart rate was also optimized in Phase III.

DEVICE

Temporary Biventricular Pacing

Continuous temporary biventricular pacing for 24 hours at a heart rate of 90 bpm or 10 bpm above intrinsic heart rate.

Sponsors & Collaborators

  • National Heart, Lung, and Blood Institute (NHLBI)

    collaborator NIH
  • Henry M. Spotnitz

    lead OTHER

Principal Investigators

  • Henry M. Spotnitz, M.D. · Professor

Study Design

Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Model
PARALLEL

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2006-10-31
Primary Completion
2012-03-31
Completion
2012-03-31
FDA Device
Yes

Countries

  • United States

Study Locations