Selective Antegrade Cerebral Perfusion and Perioperative Optic Nerve Sheath Diameter in Ascending Aortic Surgery

NCT07800806 · Status: NOT_YET_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 134

Last updated 2026-09-02

No results posted yet for this study

Summary

In ascending aortic surgery the distal anastomosis may be constructed with the aortic cross-clamp maintained, or, where the extent of the aortic pathology and the geometry of the graft require it, after release of the cross-clamp during a period of systemic circulatory arrest. Both are established surgical approaches. Where the cross-clamp is released, selective antegrade cerebral perfusion (SACP) is an established cerebral protection technique and is applied for that purpose. Where release of the cross-clamp is not required, systemic circulatory arrest is avoided and SACP is not applied. Optic nerve sheath diameter (ONSD) measured by ocular ultrasonography is a non-invasive marker of raised intracranial pressure. Cardiopulmonary bypass may increase blood-brain barrier permeability through hypoperfusion, non-pulsatile flow, hemodilution and systemic inflammation, predisposing to cerebral edema. Perioperative increases in ONSD have been reported after open heart surgery and have been associated with postoperative delirium. Data on how SACP influences perioperative ONSD dynamics in ascending aortic surgery, and whether such changes relate to postoperative delirium, are limited.

Conditions

  • Aortic Diseases
  • Cardiac Surgical Procedures
  • Aortic Aneurysm, Thoracic
  • Delirium - Postoperative
  • Postoperative Complications (Cardiopulmonary)
  • Postoperative Complications
  • Cerebrovascular Circulation

Interventions

DIAGNOSTIC_TEST

Optic nerve sheath and optic nerve diameter ultrasonography

Ocular ultrasonography with a linear probe of approximately 7-13 MHz, participant supine with the head neutral, eyelids closed, sterile transparent dressing and gel, minimal probe pressure. Optic nerve sheath diameter is measured in the transverse plane 3 mm posterior to the entry of the optic nerve into the globe. Three measurements per eye are averaged, and the mean of the two eyes is recorded. Performed at T0, T1 and T2.

DIAGNOSTIC_TEST

Transcranial Doppler ultrasonography

Transcranial Doppler ultrasonography with a 2 MHz pulsed-wave probe. The M1 segment of the middle cerebral artery is insonated through the temporal window at approximately 45-55 mm depth, bilaterally where a window is obtainable. Three consecutive stable mean flow velocity measurements are taken per side and averaged. Performed at T0, T1 and T2, and where technically feasible during selective antegrade cerebral perfusion and/or circulatory arrest.

Sponsors & Collaborators

  • Koşuyolu Kartal Heart Training and Research Hospital

    lead OTHER

Study Design

Allocation
NON_RANDOMIZED
Purpose
BASIC_SCIENCE
Masking
SINGLE
Model
PARALLEL

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2026-09-30
Primary Completion
2028-09-30
Completion
2028-12-30

Countries

  • Turkey (Türkiye)

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT07800806 on ClinicalTrials.gov