A Clinical Study Used to Estimate Central Venous Pressure Non-invasively Using Occlusion Pressure
NCT07583680 · Status: NOT_YET_RECRUITING · Type: OBSERVATIONAL · Enrollment: 30
Last updated 2026-05-13
Summary
The purpose of this study is to collect different measurements using a method called peripheral venous pressure (PVP). PVP checks the pressure in the veins in the arms or legs. It can give doctors a good idea of how well the heart is working, similar to another method called central venous pressure (CVP), which doctors use in hospitals. In this study, the research team will measure PVP in people aged 0-17. The researcher hopes that this data will help doctors understand how PVP measurements relate to health outcomes, which could lead to better ways to diagnose and treat patients in the future.
The peripheral venous pressure (PVP) device will be used to non-invasively measure the pressure required to stop blood flow in the forearm, which will indirectly measure the PVP in the forearm. This device is composed of a pressure sensor and a Doppler flow detector that will be connected to a research laptop for data collection. This device will be placed on the forearm.
If you agree to be in this study, the study team will monitor the venous flow rate (the amount of blood moving through the veins over a certain period of time) using a Doppler Flow Detector while applying pressure to the vein with a pressure sensor. This will take place on the forearm.
The internal jugular vein will be identified and recorded using ultrasound imaging and Doppler sensor.
The forearm vein will be identified and marked using ultrasound imaging. Pressure will be applied for 15 seconds, and then stopped and repeated 4 times, making five sets of measurements.
The procedure may be repeated in 2-3 additional sessions during the hospital stay, if necessary.
Your participation in this study will last approximately 30 minutes.
This procedure is for research only and will not affect your regular care. This will occur during your child's stay in the PCICU/PICU. No additional study visits will be required.
The following procedures are being performed for research purposes only:
Copying information such as your medical history from your medical record; Obtaining non-invasive peripheral venous pressure measurements.
Conditions
- Pediatric Congestive Heart Failure
- Congestive Heart Failure
Sponsors & Collaborators
-
The Brett Boyer Foundation
collaborator UNKNOWN -
Le Bonheur Children's Hospital
lead OTHER
Eligibility
- Max Age
- 17 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2026-07-31
- Primary Completion
- 2027-07-31
- Completion
- 2027-12-31
More Related Trials
-
Noninvasive Assessment of Tissue Perfusion Status in Critically Ill Pediatric Patients
NCT01760044 ·Status: COMPLETED ·Phase: NA
-
Non-invasive Estimation of Pulmonary Artery Pressure in Healthy Subjects by Electrical Impedance Tomography
NCT02969486 ·Status: COMPLETED
-
Out-of-Hospital CPAP for Severe Cardiogenic Pulmonary Edema
NCT00390442 ·Status: COMPLETED ·Phase: PHASE3
-
CNAP Accuracy Dependent on Hemodynamic Variables
NCT01743846 ·Status: COMPLETED
-
Feasibility and Efficacy of Portable Non-invasive Negative Pressure Ventilation in Fontan Patients
NCT03251742 ·Status: COMPLETED ·Phase: PHASE1
-
Non-apnea Electrical Impedance Tomography for Bedside Ventilation-Perfusion Assessment: a Prospective Cross-over Validation Study
NCT07489950 ·Status: COMPLETED ·Phase: NA
-
Speckle-Tracking and Volume Expansion
NCT03702569 ·Status: COMPLETED
-
Assessment of Continuous Measurement of Transcutaneous CO2 for Evaluation of Alveolar Dead Space During Exercise
NCT03718780 ·Status: UNKNOWN ·Phase: NA
-
Evaluation of MRI Measures of Lung Water With Posture Changes in Healthy Volunteers and in Patients With Cardiac Failure
NCT01277679 ·Status: COMPLETED ·Phase: PHASE1
-
Assessment of Tidal Volume During Non Invasive Oxygenation Techniques
NCT03445455 ·Status: UNKNOWN
-
Measurement of Cardiac Output in Intensive Care Unit With Unstable Hemodynamic: Validation of Physioflow® Device Versus Trans Thoracic Echocardiography
NCT03937102 ·Status: COMPLETED
-
Positive Pressure and Gravity Affect Volumetric Capnography
NCT03853057 ·Status: COMPLETED ·Phase: NA
-
Automated Analysis of EIT Data for PEEP Setting
NCT03653806 ·Status: COMPLETED
-
Pulmonary Hemodynamics in Patients With Severe Emphysema Pre and Post BLVR
NCT02778802 ·Status: UNKNOWN
-
Measuring Lung Pressures in Critically Ill Children Who Are on Mechanical Ventilation
NCT02354365 ·Status: ACTIVE_NOT_RECRUITING
-
Cardiac Output Measurement in Pediatric Intensive Care Unit by Metabolic Monitor (Fick Method) (PEDIA-FICK-ICU)
NCT05741918 ·Status: RECRUITING ·Phase: NA
-
Wave Intensity Analysis in the Pulmonary Artery
NCT01972009 ·Status: UNKNOWN
-
Correlation Between EIT-based Pulse Wave Method for Pulmonary Perfusion Monitoring and Pulmonary Artery Catheter-based Stroke Volume Measurement
NCT07385963 ·Status: NOT_YET_RECRUITING
-
Electrical Impedance Tomography: Collapse in Dependent Areas as a Predictor of Response to Prone Position Ventilation in COVID-19 Acute Respiratory Distress Syndrome
NCT04603755 ·Status: COMPLETED
-
Physiological Effects of Lung Impedance Tomography-Guided and Plat Pressure-Guided Phigh During APRV in Patients With ARDS
NCT06696638 ·Status: RECRUITING ·Phase: NA
-
Evaluation of VITLS Compared to Traditional Inpatient Monitoring in Cardiac Shunt-Dependent Children
NCT05526768 ·Status: COMPLETED ·Phase: NA
-
Assessment of Occult Lung Stress During Lung Protective Mechanical Ventilation
NCT05675696 ·Status: WITHDRAWN ·Phase: NA
-
The Utility of Regional Bioimpedance in Chronically Ventilated Patients
NCT02951936 ·Status: WITHDRAWN ·Phase: NA
-
Evaluation of Speckle Tracking Parameters as Predictors of Successful VA SPECKLE ECMO
NCT03532529 ·Status: UNKNOWN
-
24-hour Blood Pressure Measurements and Ischemic Conditioning
NCT03303404 ·Status: COMPLETED ·Phase: NA