Clinical Follow-up of Porcelain Veneering on Titanium Crowns Produced by Different Techniques
NCT07459842 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 27
Last updated 2026-03-10
Summary
This clinical study aimed to evaluate the short-term clinical performance of porcelain-veneered titanium crowns fabricated using two different techniques: conventional casting and CAD/CAM milling. Restorations were assessed according to FDI clinical evaluation criteria with respect to esthetic, functional, and biological outcomes during follow-up appointments.Clinical evaluations took place at baseline (2 days after luting) and following 3, 6, 12, and 18 months after luting.
Conditions
- Titanium Ceramic Crown
- CAD/CAM Milling
- Titanium Casting
Interventions
- DEVICE
-
Casting Titanium-Ceramic Crown
Titanium-based ceramic crowns produced using conventional casting technique and cemented clinically.
- DEVICE
-
CAD/CAM Titanium-Ceramic Crown
Titanium-based ceramic crowns produced using CAD/CAM technology and cemented clinically.
Sponsors & Collaborators
-
Ege University Scientific Research Projects Coordination Unit
collaborator UNKNOWN -
Ege University
lead OTHER
Principal Investigators
-
Suna Toksavul, phD · Ege University
-
Tomurcuk Övül Kümbüloğlu, phD · Ege University
-
Elif Ezgi Oğuz, phD · Altinbas University
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2018-10-10
- Primary Completion
- 2021-05-04
- Completion
- 2021-06-01
Countries
- Turkey (Türkiye)
Study Locations
More Related Trials
-
Esthetic Outcome of 3D Printed Hybrid Ceramics as Final Restorations for Single Screw Retained Implant.
NCT07154602 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Evaluation of Patient Satisfaction and Shade Matching of Vita Suprinity Versus Lithium Disilicate (E-max) Ceramic Crowns in Esthetic Zone
NCT02846116 ·Status: UNKNOWN ·Phase: NA
-
RCT of BLT Implants Used for Immediate vs Early Placement, Restored With Ceramic Crowns on Titanium Bonding Bases.
NCT05079542 ·Status: UNKNOWN ·Phase: NA
-
Clinical Study of Porcelain-fused and IPS e.Max CAD Crowns
NCT01835821 ·Status: UNKNOWN ·Phase: NA
-
Clinical Evaluation of CAD/CAM vs. Conventional Veneer Restorations
NCT06969911 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Evaluation of the Aesthetic Outcome of Lithium Disilicate (e.Max) All Ceramic Crowns on Titanium Implant Abutments in the Aesthetic Zone After Different Color Masking Approaches
NCT03686267 ·Status: COMPLETED ·Phase: NA
-
Clinical Evaluation of Full Contour Zirconia Chairside CAD/CAM Crowns
NCT06173167 ·Status: RECRUITING ·Phase: NA
-
Computer Assisted Implant Surgery and Immediate Loading
NCT01866696 ·Status: COMPLETED ·Phase: NA
-
Adjustment Period for Partial Crowns
NCT07051590 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Short Implants Supporting Single Crowns in the Posterior Region
NCT05081050 ·Status: COMPLETED
-
Evaluation of Clinical Wear and Surface Roughness of Partial Restorations Produced by Additive and Subtractive Manufacturing Methods: A Split-Mouth Randomized Controlled Clinical Trial
NCT07057401 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Wear Characteristics and Clinical Performance of Lithium Silicate Versus Monolithic Zirconia Crowns.
NCT03530020 ·Status: UNKNOWN ·Phase: NA
-
Retention of Computer Aided Design and Computer Aided Manufacturing Titanium Versus Co/Cr Single Dentures.
NCT03675594 ·Status: UNKNOWN ·Phase: NA
-
Study of Wear in Composite Resin and Reinforced Acrylic Denture Teeth Used in Complete Denture Construction for Completely Edentulous Patients
NCT04839640 ·Status: COMPLETED ·Phase: NA
-
Wear Behavior of Milled Posterior Crowns Fabricated From the New Monolithic Zirconia 5Y-TZP/3Y-TZP Compared to Lithium Disilicate
NCT04805281 ·Status: UNKNOWN ·Phase: NA
-
Conventionally vs. Digitally Fabricated Complete Dentures: Clinical Treatment Outcome Differences
NCT02521935 ·Status: WITHDRAWN ·Phase: NA
-
One-Tooth One-Time (1T1T) A Straightforward Approach to Replace Missing Teeth in the Posterior Region: a Case Series
NCT02898311 ·Status: UNKNOWN ·Phase: NA
-
Clinical Evaluation of Chairside CAD/CAM Nano-ceramic Restorations
NCT01464294 ·Status: TERMINATED
-
Clinical Efficacy of Angulated Screw-retained and Cemented Single Implant Crowns in Esthetic Region
NCT04539912 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Aesthetic Outcomes of the Single Crowns Supported by Tissue Level Implants
NCT02061930 ·Status: UNKNOWN
-
Retrospective Study on Clinical Performance of Screw-retained Implant Crowns
NCT04370314 ·Status: COMPLETED ·Phase: NA
-
Comparison of Two Implant Prosthetic Pathways
NCT02905838 ·Status: COMPLETED ·Phase: NA
-
Minimally Invasive Treatment of Worn Dentition With Innovative CAD-CAM Composites
NCT02828696 ·Status: UNKNOWN ·Phase: NA
-
Clinical Outcomes of Biologically Oriented Preparation Technique
NCT06496828 ·Status: RECRUITING ·Phase: NA
-
Surface Hardness and Wear Characteristics of Prefabricated and CAD/CAM Milled Artificial Teeth
NCT06179615 ·Status: COMPLETED ·Phase: NA