Evaluation of a Single-lead ECG Patch-based Telemetry System for In-hospital Monitoring
NCT07260721 · Status: NOT_YET_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 100
Last updated 2025-12-03
Summary
"This investigator-initiated, prospective, single-center clinical study evaluates the performance and clinical utility of a single-lead electrocardiogram (ECG) patch-based telemetry system for hospitalized patients who require in-hospital telemetry ECG monitoring. The system integrates real-time centralized surveillance (MEMO-Cue) with post-hoc analytic review (MEMO-Care) using ECG signals recorded by the MEMO Patch M, aiming to enable timely recognition of clinically important arrhythmias and to inform treatment decisions under routine inpatient conditions.
Adults (≥19 years) indicated for continuous ECG monitoring during admission are enrolled after written informed consent, with a planned sample size of 100 to yield approximately 90 evaluable participants (10% anticipated dropout). The design does not include randomization or blinding. Study procedures include a screening visit (eligibility and baseline data), an inpatient monitoring period of at least 12 hours and up to 8 days with simultaneous MEMO-Cue monitoring and MEMO Patch M recording, and an end-of-visit assessment when MEMO-Care analytic results become available. Concomitant therapies deemed clinically necessary are permitted and documented, and adverse events are prospectively assessed.
Clinical utility endpoints quantify care impact and timeliness: (1) rate of treatment plan changes (e.g., initiation or modification of anticoagulants or antiarrhythmic drugs, cardioversion scheduling, device implantation, or other actions); (2) time to recognition (days) of major arrhythmias-atrial fibrillation (AF), ventricular tachycardia (VT), pause, ventricular premature complex (VPC), and supraventricular tachycardia (SVT)-based on MEMO-Cue alarms or MEMO-Care results with objective confirmation; (3) reduction ratio in recognition time when identified earlier by MEMO-Cue versus MEMO-Care; and (4) proportion of participants with shortened recognition time by MEMO-Cue.
Clinical performance endpoints assess detection characteristics and agreement between MEMO-Cue alarms and MEMO-Care findings: (1) clinical sensitivity (true positive / \[true positive + false negative\]); (2) precision, i.e., positive predictive value (true positive / \[true positive + false positive\]); and (3) positive concordance rate (proportion of MEMO-Care-detected arrhythmias alerted by MEMO-Cue). Safety is captured as treatment-emergent adverse events after device application, including device-related skin reactions, detachment, or signal dropouts, with severity graded per NCI-CTCAE v5.0 and relationship to device recorded.
By characterizing real-time patch-based telemetry alongside analytic review and its influence on diagnostic timing and management, the study aims to generate practical evidence supporting feasibility, reliability, and workflow compatibility of single-lead patch telemetry for in-hospital ECG monitoring.
Conditions
- Arrhythmias
- Atrial Fibrillation
- Ventricular Tachycardia
- Supraventricular Tachycardia
- Bradycardia
- Telemetry
- Patient Monitoring
- Hospitalization
Interventions
- DEVICE
-
MEMO-Cue-based telemetry monitoring
In-hospital telemetry electrocardiogram monitoring using the MEMO-Cue system, which integrates a single-lead patch-type Holter device (MEMO Patch M) with a central monitoring software (MEMO-Cue) and an analysis platform (MEMO Care). Participants requiring continuous ECG telemetry during hospitalization are monitored for at least 12 hours and up to 8 days to evaluate the system's clinical utility and performance in real-time arrhythmia detection compared with retrospective analysis using MEMO Care.
Sponsors & Collaborators
-
Yonsei University
lead OTHER
Study Design
- Allocation
- NON_RANDOMIZED
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 19 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2025-12-31
- Primary Completion
- 2026-05-31
- Completion
- 2026-09-30
Countries
- South Korea
Study Locations
More Related Trials
-
Evaluation of an Innovative Smart T-shirt Capable to Monitor ECG Signal and Related Parameters Through the Comparison With a Holter ECG and a Smartwatch
NCT05771142 ·Status: UNKNOWN
-
COVID-19 Remote Monitoring
NCT04350476 ·Status: WITHDRAWN ·Phase: NA
-
Monitoring Patients With Acute Cardiac Disease Using a Wireless, Wearable, Non-invasive Monitor
NCT04635371 ·Status: COMPLETED
-
Evaluation of Clinical Utility of Non-invasive Hemodynamic Monitoring Device
NCT05996965 ·Status: RECRUITING
-
A Home Telemonitoring System for Wearable Fetal-ECG and EHG Acquisition During Pregnancy
NCT06031142 ·Status: COMPLETED
-
Telemetry for Chest Pain of Low Risk for Acute Coronary Syndrome Pts
NCT02330328 ·Status: WITHDRAWN ·Phase: NA
-
Proactive Risk Evaluation for Cardiac Implantable Electronic Device Strategy Using AI-ECG
NCT07217236 ·Status: RECRUITING ·Phase: NA
-
A Trial of Telemonitoring in Adults With Heart Failure
NCT01393314 ·Status: COMPLETED ·Phase: NA
-
Telemedicine in High-Risk Cardiovascular Patients Post-ACS
NCT05015634 ·Status: COMPLETED ·Phase: NA
-
Biomedical Shirt-based ECG Monitoring
NCT03068169 ·Status: UNKNOWN
-
Description of Patient Adherence to Heart Failure Remote Monitoring and Its Determinants
NCT06723509 ·Status: RECRUITING
-
Clinical Application Study of Wearable Multi-channel Electrocardiogram Acquisition Equipment in the Diagnosis of Myocardial Ischemia in Patients with Suspected CHD
NCT06868940 ·Status: NOT_YET_RECRUITING
-
"Hypotension Probability Indicator" in TAVI/MitraClip for Hypotension Management
NCT06347211 ·Status: COMPLETED ·Phase: NA
-
Vital Signs Patch: Automated Monitoring of Vital Signs Measurements in the In-Patient Hospital Setting
NCT02518100 ·Status: COMPLETED ·Phase: NA
-
Wearable ECG for AF Screening and Stroke Risk Assessment
NCT06907264 ·Status: NOT_YET_RECRUITING
-
Wearable Devices for Patient Monitoring in Long QT Syndrome
NCT06887387 ·Status: RECRUITING
-
Vital Signs Patch Early Feasibility and Usability Study v1.0
NCT02524470 ·Status: COMPLETED ·Phase: NA
-
ECG Validation Study
NCT05445726 ·Status: ACTIVE_NOT_RECRUITING ·Phase: PHASE2
-
PREVENT - Prospective Rhythm Event Surveillance in the ER With NetGuard
NCT00750958 ·Status: COMPLETED ·Phase: NA
-
Non-invasive Pulmonary Artery Prediction
NCT05622695 ·Status: UNKNOWN
-
A Study of Mayo Clinic CV Research Heart & Voice Study
NCT07224685 ·Status: RECRUITING
-
Holter Monitoring of Critically-ill Childern in PICU at Sohag University Hospital
NCT05312333 ·Status: UNKNOWN
-
Necklace-Shaped Sensor for Non-Invasive Remote Monitoring of Vitals
NCT02337790 ·Status: COMPLETED
-
Telemonitoring Versus Usual Care
NCT01056640 ·Status: COMPLETED ·Phase: PHASE2/PHASE3
-
Non-contact ECG Sensor System for COVID19
NCT04341506 ·Status: UNKNOWN