Biomedical Shirt-based ECG Monitoring
NCT03068169 · Status: UNKNOWN · Type: OBSERVATIONAL · Enrollment: 220
Last updated 2017-06-08
Summary
Cardiovascular diseases (CVD) are associated with high healthcare costs, as well as are a leading cause of mortality and hospitalizations. The main challenge for today's researchers is to develop new technologies, which may help to improve diagnosis of CVD, thereby reducing healthcare costs and quality of patients' lives. Non-invasive wearable electronics offer new capabilities for the diagnosis and management of patients with CVD. Several reports with wearable electronics have been published, in which achieved very positive results with high accuracy. Aim of our study is to show utility of biomedical shirt-based ECG monitoring of patients with CVD in different clinical situations using Nuubo® ECG (nECG) system.
Conditions
- ECG Monitoring
Sponsors & Collaborators
-
Medical University of Warsaw
lead OTHER
Principal Investigators
-
Renata Główczyńska, PhD · 1st Department of Cardiology Medical University of Warsaw
-
Paweł Balsam, PhD · 1st Department of Cardiology Medical University of Warsaw
-
Piotr Lodziński, PhD · 1st Department of Cardiology Medical University of Warsaw
-
Marcin Grabowski, PhD · 1st Department of Cardiology Medical University of Warsaw
Eligibility
- Min Age
- 5 Years
- Max Age
- 100 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2017-06-15
- Primary Completion
- 2018-09-01
- Completion
- 2018-12-31
Countries
- Poland
Study Locations
More Related Trials
-
Cardiac Monitor Employee Study
NCT03826225 ·Status: COMPLETED
-
Optimizing Radiation Dose and Utilizing Wearable Devices to Reduce Arrhythmia Risk in Patients Undergoing Thoracic Radiotherapy: A Prospective Cohort Study
NCT06897189 ·Status: NOT_YET_RECRUITING
-
Wearable Devices for Patient Monitoring in Long QT Syndrome
NCT06887387 ·Status: RECRUITING
-
Evaluation of a Single-lead ECG Patch-based Telemetry System for In-hospital Monitoring
NCT07260721 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Wearable Electrocardiogram Monitoring Device and Smartphone Application in Perioperative Pain Management
NCT04686526 ·Status: RECRUITING
-
Remotely Monitoring Patients With Chronic Conditions in Their Home
NCT03207802 ·Status: COMPLETED
-
Evaluation of an Ultraportable ECG Recording Device and Its Visualization Software for the Detection of Atrial Fibrillation
NCT03975725 ·Status: UNKNOWN ·Phase: NA
-
A Home Telemonitoring System for Wearable Fetal-ECG and EHG Acquisition During Pregnancy
NCT06031142 ·Status: COMPLETED
-
Evaluation of the Signals Electrophysiological Measured by Intelligent Textiles
NCT03805243 ·Status: TERMINATED ·Phase: NA
-
Suitability of Unobtrusive Bed Monitoring and Wrist-worn Heart Rate Monitor for Patient Monitoring
NCT03572751 ·Status: COMPLETED
-
Heartbeat Sensitivity Calibration Using the ECG Accessory
NCT01268007 ·Status: COMPLETED
-
Necklace-Shaped Sensor for Non-Invasive Remote Monitoring of Vitals
NCT02337790 ·Status: COMPLETED
-
Smart Textile Sensor System for Health Monitoring
NCT05473702 ·Status: COMPLETED
-
Non-contact ECG Sensor System for COVID19
NCT04341506 ·Status: UNKNOWN
-
HERO System - Health Monitoring for the Detection of Vital Signs and Emotional States
NCT07248969 ·Status: ACTIVE_NOT_RECRUITING
-
Hearables: Ear-ECG and PPG for Detection of Cardiac Arrhythmias
NCT06667258 ·Status: RECRUITING
-
Telemedicine in Outpatient Covid-19 Patients
NCT04471636 ·Status: UNKNOWN ·Phase: NA
-
Establishing a Non-invasive Method to Measure Your Heart's Performance
NCT02240979 ·Status: COMPLETED
-
Development and Validation of a Telemonitoring System for High-risk Cardiovascular Patients
NCT05485532 ·Status: ACTIVE_NOT_RECRUITING
-
An Evaluation of Concordance of Smartwatch ECG and One Clinical ECG and Comparison of The Two ECGS in Terms of Predictive Risks
NCT05617391 ·Status: ACTIVE_NOT_RECRUITING
-
Clinical Safety and Efficacy Testing of a Medical Device Kardi Ai, an ECG Telemetry Monitoring System
NCT07018648 ·Status: RECRUITING ·Phase: NA
-
CardioSenseSystem Compared Study Regarding Efficacy and Safety in the Monitoring of ECG
NCT03610529 ·Status: UNKNOWN ·Phase: NA
-
Remote Symptom Review in Patients With Implantable Diagnostic Holter
NCT06431828 ·Status: RECRUITING ·Phase: NA
-
The Collection and Transmission of Electrocardiogram Using a Wearable Device
NCT05182684 ·Status: UNKNOWN ·Phase: NA
-
Validity and Reliability of Optical Heart Rate Sensors
NCT05525000 ·Status: COMPLETED ·Phase: NA