Treatment Of Meta-diaphyseal Bone Defect In Long Bone With Titanium Mesh Cage
NCT06923579 · Status: NOT_YET_RECRUITING · Type: OBSERVATIONAL · Enrollment: 20
Last updated 2025-04-11
Summary
Meta-diaphyseal bone defects in long bones pose a significant challenge in orthopedic surgery. Traditional treatment methods include autologous bone grafts, allografts, and distraction osteogenesis. Autologous bone grafting is often considered the gold standard due to its superior biological compatibility, but it is limited by complications such as donor site morbidity and the finite quantity of available graft material. Allografts provide an alternative but are associated with risks of immune rejection and disease transmission. Distraction osteogenesis, popularized by Ilizarov, allows for gradual bone regeneration and lengthening but requires prolonged treatment periods and carries the risk of complications like pin tract infections.
In the late 1990s, titanium mesh cages, particularly the Harms cage, emerged as a novel solution for meta-diaphyseal bone defects. Originally developed for spinal surgery, these cages were adapted for long bone reconstruction due to their structural stability and biocompatibility. The cylindrical design of titanium mesh cages provides mechanical support while allowing for the containment of bone graft material and promoting vascular ingrowth. This technique enables effective reconstruction of segmental defects by combining the cage with cancellous bone grafts or other substitutes.
Recent studies have demonstrated promising outcomes with titanium mesh cages in treating meta-diaphyseal defects. High union rates and favorable functional results have been reported in long-term follow-ups. The method offers advantages such as immediate structural stability and adaptability to various clinical scenarios, making it a valuable option for addressing complex bone defects. However, like all techniques, it is not without limitations, including potential complications such as residual limb length discrepancies or recurrent infections in some cases. Nonetheless, titanium mesh cages represent a significant advancement in the management of challenging long bone defects.
Conditions
- Meta-diaphyseal Bone Defect In Long Bone
Interventions
- PROCEDURE
-
Titanium Mesh Cage
the Harms cage was adapted for long bone reconstruction due to its structural stability and biocompatibility. The cage provides immediate mechanical support while allowing for bone ingrowth, addressing the limitations of traditional methods. Advantages of the titanium mesh cage include its ability to maintain bone length, provide immediate stability, and allow for earlier weight-bearing. The porous structure facilitates vascularization and bone integration, potentially leading to improved healing outcomes
Sponsors & Collaborators
-
Assiut University
lead OTHER
Eligibility
- Min Age
- 16 Years
- Max Age
- 60 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2025-04-10
- Primary Completion
- 2028-03-25
- Completion
- 2028-03-25
More Related Trials
-
Treatment of Atrophic Nonunion Fractures by Autologous Mesenchymal Stem Cell Percutaneous Grafting
NCT01429012 ·Status: WITHDRAWN ·Phase: PHASE2
-
Unreamed Intramedullary Tibial Nailing in Treatment of Open IIIa Diaphyseal Tibial Fractures in Adults
NCT06280417 ·Status: NOT_YET_RECRUITING
-
Plate Fixation of Distal Femur Fractures: A Protocol for a Study of Two Plate Options
NCT00644397 ·Status: COMPLETED
-
A Randomized Controlled Cost Study of Infuse BMP 2 vs Iliac Crest Autograft for Non Union of Long Bone Fractures
NCT00856479 ·Status: WITHDRAWN ·Phase: PHASE4
-
Treatment of Unstable Distal Clavicular Fractures (Neer 2b): Hook Plate vs Locking Plate
NCT01555372 ·Status: UNKNOWN ·Phase: NA
-
Evaluating the Utility of Bone Grafts in Open Wedge Corrective Osteotomy and Plate Fixation
NCT06093763 ·Status: RECRUITING ·Phase: NA
-
Medial Enhancement Technique for the Treatment of Old Femoral Neck Fractures
NCT06713031 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Percutaneous Versus Open Plate Fixation of Diaphyseal Clavicle Fractures
NCT01405703 ·Status: COMPLETED
-
Short Versus Long Intramedullary Nails in the Treatment of Proximal Femur Metastasis.
NCT05969470 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Post Market Evaluation of Clinical Safety and Performance of the Fitbone Transport and Lengthening System
NCT06400732 ·Status: TERMINATED
-
Ankle Arthrodesis Nail for 2-level Pathologic Tibial Fracture
NCT04940754 ·Status: UNKNOWN ·Phase: NA
-
Evaluation the Treatment of Nonunion of Long Bone Fracture of Lower Extremities (Femur and Tibia) Using Mononuclear Stem Cells From the Iliac Wing Within a 3-D Tissue Engineered Scaffold
NCT01958502 ·Status: UNKNOWN ·Phase: PHASE2
-
The Impact of Clavicular Length Restoration in the Treatment of Non-unions of Clavicular Midshaft and Lateral Fractures
NCT03816436 ·Status: COMPLETED
-
Open Pilon With FIBERGRAFT AERIDYAN Matrix Bioactive Glass
NCT07227493 ·Status: RECRUITING
-
rhBMP-2 Versus Autograft in Critical Size Tibial Defects
NCT00853489 ·Status: TERMINATED ·Phase: PHASE4
-
Mesenchymal Stromal Cells for the Treatment of Non-union Fractures of Long Bones
NCT02230514 ·Status: COMPLETED ·Phase: PHASE1/PHASE2
-
Safety of Immediate Weight-Bearing as Tolerated After Well-Reduced Geriatric Hip
NCT06199739 ·Status: COMPLETED ·Phase: NA
-
Autologous Bone Marrow Concentration for Femoral Shaft Fracture Union
NCT03794622 ·Status: UNKNOWN
-
Intramedullary Nailing Versus External Fixation in Open Tibia Fractures in Tanzania
NCT03861624 ·Status: COMPLETED ·Phase: NA
-
Reamed Locked Plating - Metaphyseal Fractures of the Distal Femur and Tibia
NCT01553630 ·Status: TERMINATED ·Phase: NA
-
Treatment of Tibial Plateau Fractures With Bone-graft and Bone Tamp Technique
NCT04807062 ·Status: COMPLETED ·Phase: NA
-
Periprosthetic Plate Over Humeral Nail
NCT06812195 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Anterior Odontoid Screw Osteosynthesis in Treatment of Type 2 Odontoid Fracture
NCT03355703 ·Status: COMPLETED
-
Porous Tantalum Rods Improve the Hip Joint Function of Patients With Avascular Necrosis of the Femoral Head
NCT02877472 ·Status: UNKNOWN ·Phase: NA
-
Osteolysis Development Around Uncemented Cups With or Without Screw Holes
NCT03692351 ·Status: COMPLETED ·Phase: NA