Plate Fixation of Distal Femur Fractures: A Protocol for a Study of Two Plate Options
NCT00644397 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 80
Last updated 2019-08-13
Summary
Internal fixation of femur fractures improves alignment and provides stability to the bone and the surrounding soft tissues. This generally allows for early motion of the adjacent joints; thus maximizing overall function of the limb. Open reduction and internal fixation with plates and screws is the standard method that has been used in the treatment of distal femoral fractures. One common traditional method of internal fixation is the 95-degree angled blade plate. Recent advances in technology for distal femur fractures include the LCP™ Condylar Plate. This implant differs from the blade plate, because the LCP offers multiple points of fixed angle contact between the plate and screws in the distal femur. The introduction of plates with the option of locked screws has provided means to increase the rigidity of fixation in osteoporotic bone or in periarticular fractures with a small distal segment, and the LCP may be technically easier to apply than the blade plate. To the investigators' knowledge, there have been no published clinical or biomechanical studies specific to the LCP Condylar Plate, although the early results of LCP implants for other fractures are promising. The investigators believe that locked plating represents a valuable advancement in fracture treatment. However, the limitations of this new technology and the indications for its use have not been completely elucidated. Furthermore, the cost of the new technology is approximately seven times more than the traditional treatment. This is a randomized, prospective, multi-center study to compare the blade plate and the LCP in the distal femur. All patients 16 years of age or older, regardless of race or gender, with a supracondylar fracture of distal femur will be considered. Whether patients are treated with a blade plate or/and LCP, they will be receiving standard orthopedic care for their injury. Neither of these methods currently places a patient at increased surgical or post-surgical risk for problems with infection, nonunion, malunion, or other complications. Because of the study, early and late complication rates and functional outcomes after these treatments may be better defined, allowing for optimization of care of people with these injuries in the future. This should reduce not only direct and indirect costs to the individual, but also costs to society.
Conditions
- Femoral Fractures
Interventions
- DEVICE
-
95-degree Angled Blade Plate
- DEVICE
-
4.5mm Condylar Locking Plate
Sponsors & Collaborators
-
MetroHealth Medical Center
lead OTHER
Principal Investigators
-
Heather A. Vallier, M.D. · MetroHealth Medical Center
Eligibility
- Min Age
- 16 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2006-05-31
- Primary Completion
- 2018-01-31
- Completion
- 2019-01-31
Countries
- United States
Study Locations
More Related Trials
-
Minimally Invasive of Proximal Humerus Fractures With Internal Fixation Improves Shoulder Function in Older Patients
NCT02784522 ·Status: COMPLETED ·Phase: NA
-
DP Vs DFR for Management of Geriatric Distal Femur Fractures.
NCT05363943 ·Status: COMPLETED ·Phase: NA
-
Far Cortical Locking Versus Standard Constructs for Distal Femur Fractures
NCT01766648 ·Status: UNKNOWN ·Phase: NA
-
Locked Versus Unlocked Set Screws in Intramedullary Fixation of Intertrochanteric Fractures
NCT02345369 ·Status: TERMINATED ·Phase: NA
-
Carbo-fix Lateral Plate Devices and Standard Plate-Nail Constructs in Distal Femur Fractures
NCT07280169 ·Status: RECRUITING ·Phase: NA
-
Intertrochanteric Femoral Fracture Fixation Trial
NCT02627040 ·Status: UNKNOWN ·Phase: NA
-
Metaphyseal Distal Radius Fractures
NCT01156766 ·Status: COMPLETED ·Phase: NA
-
Morphological Characteristics of Inferior Pole Patellar Fractures and a Finite Element Analysis Combined with a Retrospective Clinical Study of Anchor Suture and Titanium Cable Cerclage Treatment
NCT06736639 ·Status: COMPLETED
-
Comparison of Dynamic Versus Static Lag Screw Modes for Cephalomedullary Nails Used to Fix Intertrochanteric Fragility Fractures
NCT04441723 ·Status: UNKNOWN ·Phase: NA
-
Short Versus Long Intramedullary Nails in the Treatment of Proximal Femur Metastasis.
NCT05969470 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Clinical Outcome After Treatment of Patellar Fractures With Locking Plates
NCT02015975 ·Status: COMPLETED
-
Retrograde Femoral Nail-Advanced Outcomes for Fixation of Distal Femur and Femoral Shaft Fractures
NCT05680987 ·Status: RECRUITING ·Phase: NA
-
Static Helical Screw Locking of Pertrochanteric Femur Fractures Using the TFN-A
NCT04851509 ·Status: RECRUITING ·Phase: NA
-
Comparison of Three Fixation Techniques for Displaced Distal Radius Fractures
NCT00524719 ·Status: COMPLETED ·Phase: NA
-
Timing of Orthopaedic Surgery in the Multiply-injured Patient: Development of a Protocol for Early Appropriate Care
NCT00888160 ·Status: COMPLETED
-
Reamed Locked Plating - Metaphyseal Fractures of the Distal Femur and Tibia
NCT01553630 ·Status: TERMINATED ·Phase: NA
-
Minimally Invasive Locking Plate Fixation vs Reamed Intramedullary Nail Fixation on Patients With Open Tibia Fracture
NCT04072094 ·Status: UNKNOWN ·Phase: NA
-
Combined Nail and Plate Fixation in Proximal Femoral Fractures With Lateral Wall Deficiency
NCT07277569 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Dual Implant Versus Single Implant Distal End of Femur
NCT06032299 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Fixation Methods of Basicervical Fractures
NCT04240743 ·Status: COMPLETED ·Phase: NA
-
T1Rho MRI Evaluation of Patellofemoral Changes After Tibial IM Nailing
NCT01879215 ·Status: COMPLETED ·Phase: NA
-
Three Cancellous Screws Versus Four Cancellous Screws for Femoral Neck Fixation
NCT04869332 ·Status: RECRUITING ·Phase: NA
-
Trial of a Distal Targeting System for Cephalomedullary Nails as Part of Surgical Repair of Hip and Femoral Shaft Fractures
NCT03943329 ·Status: COMPLETED ·Phase: NA
-
Assessment of Fixation Strategies for Severe Open Tibia Fractures
NCT01494519 ·Status: COMPLETED ·Phase: PHASE3
-
Management Of Patellar Fractures By Craniofacial Mesh Plate Osteosynthesis Augmented by Screws
NCT06205914 ·Status: RECRUITING ·Phase: PHASE1