Digital Analysis of Occlusal Force Distribution in Single-Tooth Implant Restorations
NCT06862973 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 20
Last updated 2025-03-10
Summary
This study will explore the impact of single tooth implant restorations upon occlusal force distribution and the accuracy of several digital analysis methods. The biomechanical behavior of implant-supported prostheses differs from that of natural teeth, and the distribution and modulation of occlusal forces are unpredictable.
The research used the Medit i700 intraoral scanner and the OccluSense system to take pre- and post-implant measurements. The research aims to determine: How are the techniques different in the registration of occlusal contacts and force magnitude? and How does occlusal balance shift following the placement of an implant? The research findings can be used to provide clinical recommendations to optimize occlusal balancing during implant prosthetics.
Conditions
- Occlusal Analysis
Interventions
- DIAGNOSTIC_TEST
-
Digital Occlusal Analysis Using Medit i700 and OccluSense in Single-Tooth Implant Restorations
This study differs from other research through the comparison of two advanced digital occlusal analysis methods-OccluSense system and MEDIT i700 intraoral scanner-to measure occlusal force distribution both before and after the insertion of single-tooth implant restorations in the posterior segment. Unlike research based upon the use of articulation paper, this study employs pressure-sensitive sensor technology (OccluSense) and scanner-based occlusion analysis (MEDIT i700) to quantitatively measure occlusal contacts and force intensity using CloudCompare and ImageJ. With the analysis of the variations that take place within the pre-and-post implant occlusion, the study provides an understanding of occlusal adaptation and how to optimize occlusal adjustments to prevent implant overload and complications, differing from the research that has previously lacked both digital force mapping and longitudinal occlusal analysis.
Sponsors & Collaborators
-
Konya Necmettin Erbakan Üniversitesi
lead OTHER
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2024-09-30
- Primary Completion
- 2025-01-30
- Completion
- 2025-01-30
Countries
- Turkey (Türkiye)
Study Locations
More Related Trials
-
The Influence of Mucosal Tissue Thickness on Soft and Hard Tissue Changes Around Implants
NCT02580721 ·Status: UNKNOWN ·Phase: NA
-
Effect of Open Tray Versus Digital Impressions on the Passivity and Prosthetic Complications of Full Arch Screw-retained Prosthesis
NCT04848207 ·Status: UNKNOWN ·Phase: NA
-
Abutment Macro Design and Peri-implant Tissues
NCT02546713 ·Status: COMPLETED ·Phase: NA
-
A Comparison Between Protemp and Flowable Light Cure Composite Material for Creating Optimal Gingival Emergence Profile Around Implant
NCT07196293 ·Status: COMPLETED ·Phase: NA
-
The Use of a Fully Digital Workflow in Immediate Implants With Immediate Restoration
NCT07294820 ·Status: RECRUITING
-
Conventional Impressions Versus Digital Impression Techniques for Implant Supported Screw Retained Prosthesis
NCT05912725 ·Status: COMPLETED ·Phase: NA
-
Digital Evaluation of Accuracy for Removable Partial Denture Frameworks
NCT06412159 ·Status: COMPLETED ·Phase: NA
-
Evaluating the Accuracy of Dynamic Navigation in Implant Surgery for Full Arch Prosthesis
NCT06963242 ·Status: RECRUITING ·Phase: NA
-
Effect of Abutment Configuration on Peri-implant Soft and Hard Tissue in the Esthetic Zone - Randomized Clinical Trial
NCT06407271 ·Status: RECRUITING ·Phase: NA
-
Comparison Between Conventional and Digital Workflow in Dental Prosthesis
NCT06215781 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Digital Versus Conventional Techniques for Construction of Mandibular Implant Retained Overdenture
NCT06139003 ·Status: COMPLETED ·Phase: NA
-
Time-dependent Change in the Retention Force of the Implant Overdenture
NCT05675566 ·Status: COMPLETED
-
3D Integration of Facial , Intraoral Scanning and CBCT on Patient Satisfaction and Occlusion of Temporary, Permanent Implant Supported Prosthesis
NCT06846372 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Evaluation Of Marginal Bone Height Changes And Biting Force In Screw Retained Implant Prostheses Using Reinforced Resin Vs Monolithic Zirconium
NCT07007572 ·Status: RECRUITING ·Phase: PHASE2
-
Anterior Mandibular Region for Immediate Implant Placement
NCT06527950 ·Status: ACTIVE_NOT_RECRUITING
-
Comparison of Different Materials Contribution to Implants Stability
NCT03501199 ·Status: COMPLETED ·Phase: NA
-
Passive Fit and Time Efficiency in All On-X Implants Protocols Using Photogrammetry, Splinted Scan Bodies, and Conventional Impression Technique
NCT07235072 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Peri-implant Mucosal Changes Over Time Following Implant Provisional Removal in the Esthetic Zone
NCT06783595 ·Status: RECRUITING
-
Digital Technique to Analyze the Wear of Implants and Natural Tooth as Antagonist.
NCT05842655 ·Status: COMPLETED ·Phase: NA
-
Effect of Concentrated Growth Factors on Short Implant-Supported Overdentures
NCT06880965 ·Status: COMPLETED ·Phase: PHASE2/PHASE3
-
Occlusal Balance Effect on Mandibular Bone Density by Using Fractal Analysis in Complete Denture Patients (Split-Mouth Study)
NCT06320704 ·Status: RECRUITING
-
Implant Retained Rehabilitation With Surgical and Prosthetic Digital Workflow
NCT04066309 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Retention, Chewing Efficiency and Masticatory Performance of Partial Dentures Opposing Implant Retained Prosthesis.
NCT05999760 ·Status: COMPLETED ·Phase: NA
-
Occlusal Forces and Muscle Activity in Fixed Versus Removable Mandibular Implant Supported Overdenture
NCT05949151 ·Status: COMPLETED ·Phase: NA
-
Impact of Mandibular Overdenture Base Construction Techniques on Assessment of Occlusion
NCT06080815 ·Status: COMPLETED ·Phase: NA