Comparison of SmartGuard vs Temp Target in Patients With Type 1 Diabetes Users of Advanced Hybrid Closed Loop System (AHCL) in Anaerobic Physical Activity.
NCT06728423 · Status: NOT_YET_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 14
Last updated 2025-09-25
Summary
Patients meeting the inclusion criteria will be identified. An informed consent form will be completed. Clinical data and baseline CGM will be collected at this appointment. During the session, an attempt will be made to establish a physical activity classification (PA0: inactive, PA1: 1-2 times per week, and PA2: more than twice per week) to determine if the patient is physically active, which is defined as at least 60 minutes of physical activity per week during the past 6 months. In addition, the patient will be asked whether or not they perform strength exercises and how regularly they do so. At the end of the first visit, they will be randomized by an electronically generated numerical sequence using the Randomizer for Clinical Trial Lite application. The patient will be scheduled to attend a supervised exercise session at the Pontificia Universidad Javeriana Sports Training Center.
Participants will have a blood glucose test prior to beginning physical activity. The target for starting exercise is 126-180 mg/dl. If the patient has a value less than 90 mg/dl, 20 grams of carbohydrates will be given; if the value is between 90-126 mg/dl, 10 grams will be given (above the investigators said that for anaerobics it could be from 90 mg/dl). If the value is higher than 200 mg/dl, the correction with rapid insulin is calculated according to your usual management. A new glucose test is performed 15 minutes later to confirm that the patient is within the target range. If the patient is within the target range, exercise is performed. If the reading remains above 200, the exercise session is canceled.
All participants are in SmartGuard mode on the Minimed 780G system. In the control group, the time target is activated 60 minutes before the activity and turned off 15 minutes after the end of the exercise. Participants randomized to SmartGuard will have no changes in device programming. Glucose measurements will be taken at the beginning and end of the exercise session. In addition, a Hooper Index will be calculated to standardize the patient's rest and recovery prior to the session. The strength training session will begin with a brief 15-minute warm-up emphasizing joint flexibility. The workout will consist of 3 sets of 10 repetitions of the following exercises: leg press, chest press, seated row. The estimated weight at which the exercises will be performed will be 60-80% of the 1-RM calculated for each patient. There will be a 90 second timed rest between each set of exercises. The total duration of the training will be 45 minutes. The strength training session begins with a short 15-minute warm-up focusing on joint flexibility. The workout consists of 3 sets of 10 repetitions of the following exercises: leg press, chest press, seated row. The estimated weight at which the exercises are performed is 60-80% of the 1-RM calculated for each patient. A timed rest of 90 seconds will be provided between each set of exercises. The total duration of the training will be 45 minutes. The parameter used to monitor intensity will correspond to the Borg scale measurement and heart rate monitoring. For each participant, the anthropometric variables will be entered into the application in order to perform the exact calculation of the target maximum heart rate (HR) percentage. The activity begins with a 5-minute warm-up at low intensity (55-65% of maximum HR, Borg 9-11), then 35 minutes at moderate intensity (70-80% of maximum HR, Borg 12-13), and ends with a 5-minute cool-down (maximum HR less than 55%). Alarms are set on the device to maintain the desired intensity. Glucose testing is performed at the beginning and end of the activity.
A 14-day washout period will be carried out, after which the group of patients initially assigned to temporary target activation will perform the same exercise in SmartGuard mode; likewise, the group initially assigned to SmartGuard will do so under temporary target mode. For this second session, the same procedure and recommendations already mentioned will be carried out.
CGM data will be collected through integrated continuous glucose monitoring, which downloads the information to the Carelink portal and is accessed online.
Conditions
- Type 1 Diabetes (T1D)
- Exercise
Interventions
- OTHER
-
Temporary target during an anaerobic training session
Temporary target during an anaerobic training session
- OTHER
-
SmartGuard during an anaerobic training session
SmartGuard during an anaerobic training session
Sponsors & Collaborators
-
Hospital Universitario San Ignacio
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- CROSSOVER
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2025-11-01
- Primary Completion
- 2027-11-30
- Completion
- 2027-11-30
- FDA Device
- Yes
Countries
- Colombia
Study Locations
More Related Trials
-
Closed-loop Control of Glucose Levels in the Context of Exercise in Adults With Type-1 Diabetes
NCT01297946 ·Status: COMPLETED ·Phase: PHASE1/PHASE2
-
The SMART B Exercise Study :''The SMART Study''
NCT05133765 ·Status: COMPLETED ·Phase: NA
-
ADvanced Hybrid Closed Loop Study in Adult Population With Type 1 Diabetes
NCT04235504 ·Status: COMPLETED ·Phase: NA
-
Closed-loop Control of Glucose Levels (Artificial Pancreas) for 12 Days in Adults With Type 1 Diabetes
NCT02846831 ·Status: COMPLETED ·Phase: PHASE2
-
Clinical Effectiveness of Advanced Hybrid Closed-loop Systems for Achieving Time in Tight Range Among T1D Patients
NCT06834334 ·Status: COMPLETED
-
Real-life Follow-up of the Physical Activity in Type 1 Diabetes Participants Equipped With an Insulin Pump With Hybrid Closed Loop
NCT07015970 ·Status: COMPLETED
-
The Impact of Hybrid Closed-loop Insulin Delivery in Type 1 Diabetes on Glycemic Control and PROMs
NCT04414280 ·Status: ACTIVE_NOT_RECRUITING
-
Smartguard Use in Real Life : a Longitudinal Study in Patients With Type 1 Diabetes
NCT03047486 ·Status: COMPLETED
-
Management of Prolonged Aerobic exeRcise in Patients With Type 1 Diabetes on Advanced Technologies
NCT05936203 ·Status: COMPLETED ·Phase: NA
-
Accelerometer Use in the Prevention of Exercise-Associated Hypoglycemia in Type 1 Diabetes: Outpatient Exercise Protocol
NCT02047643 ·Status: COMPLETED ·Phase: NA
-
Advanced Hybrid Closed Loop System (AHCL) in Older Patients With Type 1 Diabetes Mellitus
NCT06236256 ·Status: RECRUITING ·Phase: NA
-
Improving Glycemic Control With Electrical Stimulation
NCT03947697 ·Status: RECRUITING ·Phase: NA
-
Hybrid Closed Loop Pivotal Trial in Type 1 Diabetes
NCT02463097 ·Status: COMPLETED ·Phase: NA
-
Optimizing Metabolic Control in Type 1 Diabetes - The Automatic Bolus Calculator Flash Study
NCT03682237 ·Status: COMPLETED ·Phase: NA
-
Study of Insulin Pump in Prevention of Low Glucose Events in Adults With Type 1 Diabetes at Risk of Severe Hypoglycemia
NCT02657213 ·Status: COMPLETED ·Phase: NA
-
Closed-loop Control of Glucose Levels (Artificial Pancreas) During Exercise in Adults With Type 1 Diabetes
NCT01930110 ·Status: COMPLETED ·Phase: PHASE2
-
Use of Real-time Continuous Glucose Monitoring System in Patients With Type 1 Diabetes Mellitus
NCT00824148 ·Status: COMPLETED ·Phase: NA
-
Comparison With Observational Methods and Performance Assessment From Real-life Experience of Closed-Loop Insulin Delivery Systems
NCT05932966 ·Status: COMPLETED
-
Closed-loop Control of Glucose Levels (Artificial Pancreas) During Postprandial Exercise in Adults With Type 1 Diabetes
NCT02855307 ·Status: COMPLETED ·Phase: PHASE2
-
Clinical Utility of Tight Objectives of Advanced Hybrid Closed-loop Systems Among Type 1 Diabetes Patients (TightT1AHCL)
NCT06466967 ·Status: COMPLETED
-
Insulin-based Strategies to Prevent Hypoglycemia During Exercise
NCT03349489 ·Status: UNKNOWN ·Phase: NA
-
Study of MiniMed™ 640G Insulin Pump With SmartGuard™ in Prevention of Low Glucose Events in Adults With Type 1 Diabetes
NCT02733991 ·Status: COMPLETED ·Phase: NA
-
Exercise-Induced Hypoglycemia Prevention in Adults With Type 1 Diabetes Using an Artificial Pancreas
NCT03859401 ·Status: COMPLETED ·Phase: NA
-
The MiniMed™ 780G Glycemic Control and Quality of Life Study for the Treatment of Pediatric and Adult Subjects With Type 1 Diabetes in France.
NCT04308291 ·Status: COMPLETED
-
24/7 Closed-loop in Older Subjects With Type 1 Diabetes
NCT04025762 ·Status: COMPLETED ·Phase: NA